Ava Nikbin1, Zahra Dalili Kajan2, Mehran Taramsari3, Negar Khosravifard2.
Abstract
PURPOSE: To assess the effects of object position in the field of view (FOV) and application of a metal artifact reduction (MAR) algorithm on the diagnostic accuracy of cone-beam computed tomography (CBCT) for the detection of vertical root fractures (VRFs).Entities:
Keywords: Artifact; Cone-Beam Computed Tomography; Diagnosis; Tooth Fracture
Year: 2018 PMID: 30607348 PMCID: PMC6305778 DOI: 10.5624/isd.2018.48.4.245
Source DB: PubMed Journal: Imaging Sci Dent ISSN: 2233-7822
Fig. 1A photograph showing the phantom fabricated for the placement of teeth after tooth insertion.
Fig. 2Cone-beam computed tomographic images with central positioning of the object in the field of view. An axial image (A) and cross-sectional images (B and C) reveal root fracture of the left second tooth.
Fig. 3Cone-beam computed tomographic images with peripheral positioning of the object in the field of view. An axial image (A) and cross-sectional images (B and C) reveal root fracture of the left second tooth.
Comparison of the frequency of correct diagnoses of vertical root fractures by the 3 observers on cone-beam computed tomographic scans taken with different modes according to the position of the object in the field of view and application of the metal artifact reduction (MAR) algorithm
Inter-observer agreement among the 3 observers using kappa statistics
MAR: metal artifact reduction
Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative likelihood ratio (LR−) for different imaging modes according to the position of the object in the field of view and application of the metal artifact reduction algorithm for the 3 observers
MAR: metal artifact reduction
Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative likelihood ratio (LR−) for different imaging modes according to the position of the object in the field of view for the 3 observers in the absence of intracanal posts
MAR: metal artifact reduction
Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative likelihood ratio (LR−) for different imaging modes according to the position of the object in the field of view for the 3 observers in the presence of an intracanal post
MAR: metal artifact reduction