Literature DB >> 28733968

On the Nature of Mass Spectrometer Analyzer Contamination.

Yang Kang1, Bradley B Schneider2, Thomas R Covey2.   

Abstract

Sample throughput in electrospray ionization mass spectrometry (ESI-MS) is limited by the need for frequent ion path cleaning to remove accumulated debris that can lead to charging and general performance degradation. Contamination of ion optics within the vacuum system is particularly problematic as routine cleaning requires additional time for cycling the vacuum pumps. Differential mobility spectrometry (DMS) can select targeted ion species for transmission, thereby reducing the total number of charged particles entering the vacuum system. In this work, we characterize the nature of instrument contamination, describe efforts to improve mass spectrometer robustness by applying DMS prefiltering to reduce contamination of the vacuum ion optics, and demonstrate the capability of DMS to extend the interval between mass spectrometer cleaning. In addition, we introduce a new approach to effectively detect large charged particles formed during the electrospray ionization (ESI) process. Graphical Abstract ᅟ.

Entities:  

Keywords:  Clusters; Contamination; DMS prefiltering; Robustness

Year:  2017        PMID: 28733968     DOI: 10.1007/s13361-017-1747-3

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  23 in total

Review 1.  Biochemical applications of mass spectrometry in pharmaceutical drug discovery.

Authors:  Kieran F Geoghegan; Michele A Kelly
Journal:  Mass Spectrom Rev       Date:  2005 May-Jun       Impact factor: 10.946

2.  Solution and gas-phase H/D exchange of protein-small-molecule complexes: Cex and its inhibitors.

Authors:  Yang Kang; Peran Terrier; Chuanfan Ding; D J Douglas
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-18       Impact factor: 3.109

3.  Stable gradient nanoflow LC-MS.

Authors:  Bradley B Schneider; Xu Guo; Lorne M Fell; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2005-09       Impact factor: 3.109

Review 4.  Ion mobility-mass spectrometry.

Authors:  Abu B Kanu; Prabha Dwivedi; Maggie Tam; Laura Matz; Herbert H Hill
Journal:  J Mass Spectrom       Date:  2008-01       Impact factor: 1.982

5.  An electrospray-ionization mass spectrometer with new features.

Authors:  S K Chowdhury; V Katta; B T Chait
Journal:  Rapid Commun Mass Spectrom       Date:  1990-03       Impact factor: 2.419

Review 6.  Studying noncovalent protein complexes by electrospray ionization mass spectrometry.

Authors:  J A Loo
Journal:  Mass Spectrom Rev       Date:  1997 Jan-Feb       Impact factor: 10.946

Review 7.  Differential mobility spectrometry/mass spectrometry history, theory, design optimization, simulations, and applications.

Authors:  Bradley B Schneider; Erkinjon G Nazarov; Frank Londry; Paul Vouros; Thomas R Covey
Journal:  Mass Spectrom Rev       Date:  2015-05-11       Impact factor: 10.946

8.  Using a nanoelectrospray-differential mobility spectrometer-mass spectrometer system for the analysis of oligosaccharides with solvent selected control over ESI aggregate ion formation.

Authors:  Daren S Levin; Paul Vouros; Raanan A Miller; Erkinjon G Nazarov
Journal:  J Am Soc Mass Spectrom       Date:  2006-11-30       Impact factor: 3.109

9.  Performance enhancement in the measurement of 5 endogenous steroids by LC-MS/MS combined with differential ion mobility spectrometry.

Authors:  Julie A Ray; Mark M Kushnir; Richard A Yost; Alan L Rockwood; A Wayne Meikle
Journal:  Clin Chim Acta       Date:  2014-08-09       Impact factor: 3.786

10.  Assessing the dynamic range and peak capacity of nanoflow LC-FAIMS-MS on an ion trap mass spectrometer for proteomics.

Authors:  Jesse D Canterbury; Xianhua Yi; Michael R Hoopmann; Michael J MacCoss
Journal:  Anal Chem       Date:  2008-08-12       Impact factor: 6.986

View more
  6 in total

1.  Design Characteristics to Eliminate the Need for Parameter Optimization in Nanoflow ESI-MS.

Authors:  Yang Kang; Bradley B Schneider; Leigh Bedford; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2019-08-15       Impact factor: 3.109

2.  Methods for Quantifying the Metabolic Boundary Fluxes of Cell Cultures in Large Cohorts by High-Resolution Hydrophilic Liquid Chromatography Mass Spectrometry.

Authors:  Ryan A Groves; Maryam Mapar; Raied Aburashed; Luis F Ponce; Stephanie L Bishop; Thomas Rydzak; Marija Drikic; Dominique G Bihan; Hallgrimur Benediktsson; Fiona Clement; Daniel B Gregson; Ian A Lewis
Journal:  Anal Chem       Date:  2022-06-14       Impact factor: 8.008

Review 3.  Metabolomics: The Key to Unraveling the Role of the Microbiome in Visceral Pain Neurotransmission.

Authors:  Adam Shute; Dominique G Bihan; Ian A Lewis; Yasmin Nasser
Journal:  Front Neurosci       Date:  2022-06-23       Impact factor: 5.152

4.  A High-Resolution Mass Spectrometry-Based Quantitative Metabolomic Workflow Highlights Defects in 5-Fluorouracil Metabolism in Cancer Cells with Acquired Chemoresistance.

Authors:  Sanjay Shahi; Ching-Seng Ang; Suresh Mathivanan
Journal:  Biology (Basel)       Date:  2020-05-06

Review 5.  Review of the Use of Liquid Chromatography-Tandem Mass Spectrometry in Clinical Laboratories: Part II-Operations.

Authors:  Brian A Rappold
Journal:  Ann Lab Med       Date:  2022-09-01       Impact factor: 4.941

6.  Observation of charged droplets from electrospray ionization (ESI) plumes in API mass spectrometers.

Authors:  Clara Markert; Marco Thinius; Laura Lehmann; Chris Heintz; Florian Stappert; Walter Wissdorf; Hendrik Kersten; Thorsten Benter; Bradley B Schneider; Thomas R Covey
Journal:  Anal Bioanal Chem       Date:  2021-07-02       Impact factor: 4.142

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.