Literature DB >> 16024253

Stable gradient nanoflow LC-MS.

Bradley B Schneider1, Xu Guo2, Lorne M Fell2, Thomas R Covey2.   

Abstract

This paper demonstrates improved nanoflow LC-MS performance on a QqTOF instrument with the incorporation of a heated nanoflow interface (particle discriminator) and a nebulizer assisted sprayer. It is shown that the nebulizer broadens the usable range of electrospray potentials, simplifying the tuning procedure, particularly for negative mode nanoflow gradients. The improved desolvation capability with the particle discriminator results in signal/noise improvements of approximately 3.5x for negative ion mode samples prepared in predominantly acidified water as well as increased ion current stability. For nanoLC applications, the combined desolvation capabilities of a counter-current gas and heated laminar flow chamber provide reduced background, increased signal stability, reduced background drift, and improved protein sequence coverage when compared with data generated with only a counter-current gas for desolvation. This system is capable of subfemtomole nanoflow LC-MS sensitivity in both positive and negative ion mode across the solvent gradient.

Entities:  

Year:  2005        PMID: 16024253     DOI: 10.1016/j.jasms.2005.05.004

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  21 in total

1.  Automated 96-well SPE and LC-MS-MS for determination of protease inhibitors in plasma and cartilage tissues.

Authors:  S X Peng; S L King; D M Bornes; D J Foltz; T R Baker; M G Natchus
Journal:  Anal Chem       Date:  2000-04-15       Impact factor: 6.986

2.  Shrinking the LC landscape.

Authors:  Cheryl M Harris
Journal:  Anal Chem       Date:  2003-02-01       Impact factor: 6.986

3.  Automation of nanoscale microcapillary liquid chromatography-tandem mass spectrometry with a vented column.

Authors:  Lawrence J Licklider; Carson C Thoreen; Junmin Peng; Steven P Gygi
Journal:  Anal Chem       Date:  2002-07-01       Impact factor: 6.986

4.  The reproducible acquisition of comparative liquid chromatography/tandem mass spectrometry data from complex biological samples.

Authors:  Ian I Stewart; Li Zhao; Thierry Le Bihan; Brett Larsen; Salvatore Scozzaro; Dan Figeys; Guo Dong Mao; Olga Ornatsky; Moyez Dharsee; Chris Orsi; Rob Ewing; Theo Goh
Journal:  Rapid Commun Mass Spectrom       Date:  2004       Impact factor: 2.419

5.  Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins.

Authors:  M R Emmett; R M Caprioli
Journal:  J Am Soc Mass Spectrom       Date:  1994-07       Impact factor: 3.109

6.  Selective detection of phosphopeptides in complex mixtures by electrospray liquid chromatography/mass spectrometry.

Authors:  M J Huddleston; R S Annan; M F Bean; S A Carr
Journal:  J Am Soc Mass Spectrom       Date:  1993-09       Impact factor: 3.109

7.  Protein identification by solid phase microextraction-capillary zone electrophoresis-microelectrospray-tandem mass spectrometry.

Authors:  D Figeys; A Ducret; J R Yates; R Aebersold
Journal:  Nat Biotechnol       Date:  1996-11       Impact factor: 54.908

8.  Characterization of the microdialysis junction interface for capillary electrophoresis/microelectrospray ionization mass spectrometry.

Authors:  J C Severs; R D Smith
Journal:  Anal Chem       Date:  1997-06-01       Impact factor: 6.986

9.  Electrospray interface for liquid chromatographs and mass spectrometers.

Authors:  C M Whitehouse; R N Dreyer; M Yamashita; J B Fenn
Journal:  Anal Chem       Date:  1985-03       Impact factor: 6.986

10.  Sheathless capillary electrophoresis-electrospray ionization mass spectrometry using 10 mu m I.D. capillaries: analyses of tryptic digests of cytochrome c.

Authors:  J H Wahl; D C Gale; R D Smith
Journal:  J Chromatogr A       Date:  1994-01-21       Impact factor: 4.759

View more
  3 in total

1.  Calibrant delivery for mass spectrometry.

Authors:  Bradley B Schneider; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2007-03-23       Impact factor: 3.109

2.  Design Characteristics to Eliminate the Need for Parameter Optimization in Nanoflow ESI-MS.

Authors:  Yang Kang; Bradley B Schneider; Leigh Bedford; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2019-08-15       Impact factor: 3.109

3.  On the Nature of Mass Spectrometer Analyzer Contamination.

Authors:  Yang Kang; Bradley B Schneider; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-21       Impact factor: 3.109

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.