Literature DB >> 25110813

Performance enhancement in the measurement of 5 endogenous steroids by LC-MS/MS combined with differential ion mobility spectrometry.

Julie A Ray1, Mark M Kushnir2, Richard A Yost3, Alan L Rockwood4, A Wayne Meikle5.   

Abstract

BACKGROUND: Challenges for steroid analysis by LC-MS/MS include low ionization efficiency, endogenous isobars with similar fragmentation patterns and chromatographic retention. Differential ion mobility spectrometry (DMS) provides an additional degree of separation prior to MS/MS detection, and shows promise in improving specificity of analysis. We developed a sensitive and specific method for measurement of corticosterone, 11-deoxycortisol, 11-deoxycorticosterone, 17-hydroxyprogesterone and progesterone in human serum and plasma using an ABSciex 5500 mass spectrometer equipped with a differential ion mobility interface.
METHODS: 250μL aliquots of serum were spiked with deuterated internal standards and extracted with MTBE. The samples were analyzed using positive mode electrospray LC-DMS-MS/MS. The method was validated and compared with immunoassays and LC-MS/MS methods of reference laboratories.
RESULTS: Inter and intra assay imprecision was <10%. Limits of quantification and detection in nmol/L were 0.18, 0.09 for corticosterone and 17-hydroxyprogesterone, 0.30, 0.16 for 11-deoxycortisol, 0.12, 0.06 for progesterone and 0.06, 0.03 for 11-deoxycorticosterone. Comparison for progesterone and 17-hydroxyprogesterone with immunoassay showed slopes of 0.97 and 1.0, intercepts of 0.16 and 0.10 and coefficients of determination (r(2)) of 0.92 and 0.97, respectively. Progesterone by immunoassay showed positive bias in samples measuring <3.18nmol/L. Reference intervals for progesterone and 11-deoxycorticosterone in post-menopausal women were found to be <2.88 and <0.28nmol/L respectively.
CONCLUSIONS: We developed and validated an LC-DMS-MS/MS method for analysis of five endogenous steroids suitable for routine measurements in clinical diagnostic laboratories. Specificity gained with DMS allows reducing the complexity of sample preparation, decreasing LC run times and increasing speed of the analysis.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chemiluminiscent immunoassay (CIA); Congenital adrenal hyperplasia (CAH); Differential ion mobility spectrometry (DMS); Immunoassay (IA); Liquid chromatography–tandem mass spectrometry (LC–MS/MS); Steroids

Mesh:

Substances:

Year:  2014        PMID: 25110813     DOI: 10.1016/j.cca.2014.07.036

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  15 in total

1.  Differential mobility spectrometry: a valuable technology for analyzing challenging biological samples.

Authors:  J Larry Campbell; J C Yves Le Blanc; Richard G Kibbey
Journal:  Bioanalysis       Date:  2015       Impact factor: 2.681

2.  On the Nature of Mass Spectrometer Analyzer Contamination.

Authors:  Yang Kang; Bradley B Schneider; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-21       Impact factor: 3.109

3.  Maximizing Ion Transmission in Differential Mobility Spectrometry.

Authors:  Bradley B Schneider; Frank Londry; Erkinjon G Nazarov; Yang Kang; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2017-06-29       Impact factor: 3.109

4.  Application of Group I Metal Adduction to the Separation of Steroids by Traveling Wave Ion Mobility Spectrometry.

Authors:  Alana L Rister; Tiana L Martin; Eric D Dodds
Journal:  J Am Soc Mass Spectrom       Date:  2018-11-09       Impact factor: 3.109

5.  DMS as an orthogonal separation to LC/ESI/MS/MS for quantifying isomeric cerebrosides in plasma and cerebrospinal fluid.

Authors:  Hongbin Xu; Frederic R Boucher; Thao T Nguyen; Graeme P Taylor; Julianna J Tomlinson; Roberto A Ortega; Brigitte Simons; Michael G Schlossmacher; Rachel Saunders-Pullman; Walt Shaw; Steffany A L Bennett
Journal:  J Lipid Res       Date:  2018-11-09       Impact factor: 5.922

6.  Ambient Ionization and FAIMS Mass Spectrometry for Enhanced Imaging of Multiply Charged Molecular Ions in Biological Tissues.

Authors:  Clara L Feider; Natalia Elizondo; Livia S Eberlin
Journal:  Anal Chem       Date:  2016-11-09       Impact factor: 6.986

Review 7.  Achievements and Future Directions of the APFCB Mass Spectrometry Harmonisation Project on Serum Testosterone.

Authors:  Ronda F Greaves; Chung S Ho; Kirsten E Hoad; John Joseph; Brett McWhinney; Janice P Gill; Therese Koal; Chris Fouracre; Heidi P Iu; Brian R Cooke; Conchita Boyder; Hai T Pham; Lisa M Jolly
Journal:  Clin Biochem Rev       Date:  2016-05

8.  Formation of multimeric steroid metal adducts and implications for isomer mixture separation by traveling wave ion mobility spectrometry.

Authors:  Alana L Rister; Tiana L Martin; Eric D Dodds
Journal:  J Mass Spectrom       Date:  2019-05       Impact factor: 1.982

9.  Three-dimensional enhanced lipidomics analysis combining UPLC, differential ion mobility spectrometry, and mass spectrometric separation strategies.

Authors:  Paul R S Baker; Aaron M Armando; J Larry Campbell; Oswald Quehenberger; Edward A Dennis
Journal:  J Lipid Res       Date:  2014-09-15       Impact factor: 5.922

Review 10.  Steroid analysis by ion mobility spectrometry.

Authors:  Alana L Rister; Eric D Dodds
Journal:  Steroids       Date:  2019-10-28       Impact factor: 2.668

View more