| Literature DB >> 28727745 |
Stijn Bogaerts1, Catarina De Brito Carvalho2, Lennart Scheys3, Kaat Desloovere4, Jan D'hooge5, Frederik Maes2, Paul Suetens2, Koen Peers1.
Abstract
The Achilles tendon has a unique structure-function relationship thanks to its innate hierarchical architecture in combination with the rotational anatomy of the sub-tendons from the triceps surae muscles. Previous research has provided valuable insight in global Achilles tendon mechanics, but limitations with the technique used remain. Furthermore, given the global approach evaluating muscle-tendon junction to insertion, regional differences in tendon mechanical properties might be overlooked. However, recent advancements in the field of ultrasound imaging in combination with speckle tracking have made an intratendinous evaluation possible. This study uses high-frequency ultrasound to allow for quantification of regional tendon deformation. Also, an interactive application was developed to improve clinical applicability. A dynamic ultrasound of both Achilles tendons of ten asymptomatic subjects was taken. The displacement and regional strain in the superficial, middle and deep layer were evaluated during passive elongation and isometric contraction. Building on previous research, results showed that the Achilles tendon displaces non-uniformly with a higher displacement found in the deep layer of the tendon. Adding to this, a non-uniform regional strain behavior was found in the Achilles tendon during passive elongation, with the highest strain in the superficial layer. Further exploration of tendon mechanics will improve the knowledge on etiology of tendinopathy and provide options to optimize existing therapeutic loading programs.Entities:
Mesh:
Year: 2017 PMID: 28727745 PMCID: PMC5519157 DOI: 10.1371/journal.pone.0181364
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1US images of an Achilles tendon acquired with different central frequencies.
(a) 10MHz transducer, (b) 21MHz transducer (c) 40MHz transducer. Tendon width, length and corresponding image resolution is annotated in yellow.
Fig 2Close-up of Fig 1.
Speckle pattern width is measured for the 10MHz image (a), 21MHz image(b) and 40MHz image(c).
Fig 32D US image of volunteer with selected regions of interest (1) and subregions (2–7) delimited in red.
Fig 4Non-uniform displacement along the major deformation direction (*** = p < 0.001).
Fig 5Non-uniform regional strain along the major deformation direction (** = p = 0.002 / *** = p < 0.001 / n.s. = non significant).
Fig 6Absolute difference in mean displacement of superficial versus deep layer (** = p = 0,002).
Fig 7Interactive application.