Kornelia Kulig1, Yu-Jen Chang2, Slawomir Winiarski3, Gregory R Bashford4.
Abstract
The purpose of this study was to explore the relationship between tendon micro-morphology quantified from a sonogram and tendon mechanical characteristics measured in vivo. Nineteen adults (nine with unilateral Achilles tendinosis) participated. A commercial ultrasound scanner was used to capture longitudinal B-mode ultrasound images from the mid-portion of bilateral Achilles tendons and a custom image analysis program was used to analyze the spatial frequency content of manually defined regions of interest; in particular, the average peak spatial frequency of the regions of interest was acquired. In addition, a dynamometer and a motion analysis system indirectly measured the tendon mechanical (stiffness) and material (elastic modulus) properties. The peak spatial frequency correlated with tendon stiffness (r = 0.74, p = 0.02) and elastic modulus (r = 0.65, p = 0.05) in degenerated tendons, but not healthy tendons. This is the first study relating the mechanical characteristics of degenerated human Achilles tendon using a non-invasive micro-morphology analysis approach.Entities:
Keywords: Elastic modulus; Stiffness; Tendon mechanics; Tissue imaging
Mesh:
Year: 2015 PMID: 26718836 DOI: 10.1016/j.ultrasmedbio.2015.11.013
Source DB: PubMed Journal: Ultrasound Med Biol ISSN: 0301-5629 Impact factor: 2.998