Literature DB >> 28690712

Finite Element Analysis of the Implantation Process of Overlapping Stents.

Jiang Xu1, Jie Yang2, Salman Sohrabi3, Yihua Zhou4, Yaling Liu5.   

Abstract

Overlapping stents are widely used in vascular stent surgeries. However, the rate of stent fractures (SF) and in-stent restenosis (ISR) after using overlapping stents is higher than that of single stent implantations. Published studies investigating the nature of overlapping stents rely primarily on medical images, which can only reveal the effect of the surgery without providing insights into how stent overlap influences the implantation process. In this paper, a finite element analysis of the overlapping stent implantation process was performed to study the interaction between overlapping stents. Four different cases, based on three typical stent overlap modes and two classical balloons, were investigated. The results showed that overlapping contact patterns among struts were edge-to-edge, edge-to-surface, and noncontact. These were mainly induced by the nonuniform deformation of the stent in the radial direction and stent tubular structures. Meanwhile, the results also revealed that the contact pressure was concentrated in the edge of overlapping struts. During the stent overlap process, the contact pattern was primarily edge-to-edge contact at the beginning and edge-to-surface contact as the contact pressure increased. The interactions between overlapping stents suggest that the failure of overlapping stents frequently occurs along stent edges, which agrees with the previous experimental research regarding the safety of overlapping stents. This paper also provides a fundamental understanding of the mechanical properties of overlapping stents.

Entities:  

Keywords:  contact; finite element method; overlapping stents; stent safety; stents

Year:  2017        PMID: 28690712      PMCID: PMC5472852          DOI: 10.1115/1.4036391

Source DB:  PubMed          Journal:  J Med Device        ISSN: 1932-6181            Impact factor:   0.582


  23 in total

Review 1.  Role of stent design and coatings on restenosis and thrombosis.

Authors:  Hidehiko Hara; Masato Nakamura; Julio C Palmaz; Robert S Schwartz
Journal:  Adv Drug Deliv Rev       Date:  2006-03-06       Impact factor: 15.470

2.  Serial angiographic and intravascular ultrasound analysis of late stent strut fracture of sirolimus-eluting stents in native coronary arteries.

Authors:  Ko P Yamada; Tomomi Koizumi; Hiroshi Yamaguchi; Hideaki Kaneda; Heidi N Bonneau; Yasuhiro Honda; Peter J Fitzgerald
Journal:  Int J Cardiol       Date:  2007-12-21       Impact factor: 4.164

3.  Hemodynamics in coronary arteries with overlapping stents.

Authors:  Farhad Rikhtegar; Christophe Wyss; Kathryn S Stok; Dimos Poulikakos; Ralph Müller; Vartan Kurtcuoglu
Journal:  J Biomech       Date:  2013-11-08       Impact factor: 2.712

4.  Realistic finite element-based stent design: the impact of balloon folding.

Authors:  Matthieu De Beule; Peter Mortier; Stéphane G Carlier; Benedict Verhegghe; Rudy Van Impe; Pascal Verdonck
Journal:  J Biomech       Date:  2007-10-24       Impact factor: 2.712

5.  Intravascular ultrasonic assessment of stent diameters derived from manufacturer's compliance charts.

Authors:  Jose de Ribamar Costa; Gary S Mintz; Stéphane G Carlier; Ricardo A Costa; Kenichi Fujii; Koichi Sano; Masashi Kimura; Joanna Lui; Giora Weisz; Issam Moussa; George Dangas; Roxana Mehran; Alexandra J Lansky; Edward M Kreps; Michael Collins; Gregg W Stone; Jeffrey W Moses; Martin B Leon
Journal:  Am J Cardiol       Date:  2005-07-01       Impact factor: 2.778

6.  Incidence and predictors of drug-eluting stent fracture in human coronary artery a pathologic analysis.

Authors:  Gaku Nakazawa; Aloke V Finn; Marc Vorpahl; Elena Ladich; Robert Kutys; Isidora Balazs; Frank D Kolodgie; Renu Virmani
Journal:  J Am Coll Cardiol       Date:  2009-11-17       Impact factor: 24.094

7.  Use of multiple overlapping sirolimus-eluting stents for treatment of long coronary artery lesions: results from a single-center registry in 318 consecutive patients.

Authors:  Peter E Ruchin; Daniela Trabattoni; Franco Fabbiocchi; Piero Montorsi; Alessandro Lualdi; Paolo Ravagnani; Luca Grancini; Stefano Galli; Giovanni Teruzzi; Giuseppe Calligaris; Stefano De Martini; Antonio L Bartorelli
Journal:  Int J Cardiol       Date:  2008-06-25       Impact factor: 4.164

8.  Stent overlapping and geometric curvature influence the structural integrity and surface characteristics of coronary nitinol stents.

Authors:  Konstantinos K Kapnisis; Dina O Halwani; Brigitta C Brott; Peter G Anderson; Jack E Lemons; Andreas S Anayiotos
Journal:  J Mech Behav Biomed Mater       Date:  2012-12-13

9.  Mechanical response of cardiovascular stents under vascular dynamic bending.

Authors:  Jiang Xu; Jie Yang; Nan Huang; Christopher Uhl; Yihua Zhou; Yaling Liu
Journal:  Biomed Eng Online       Date:  2016-02-20       Impact factor: 2.819

Review 10.  Coronary stent fracture: a recently appreciated phenomenon with clinical relevance.

Authors:  Madjid Chinikar; Parham Sadeghipour
Journal:  Curr Cardiol Rev       Date:  2014-11
View more
  3 in total

1.  Virtual stenting with simplex mesh and mechanical contact analysis for real-time planning of thoracic endovascular aortic repair.

Authors:  Duanduan Chen; Jianyong Wei; Yiming Deng; Huanming Xu; Zhenfeng Li; Haoye Meng; Xiaofeng Han; Yonghao Wang; Jia Wan; Tianyi Yan; Jiang Xiong; Xiaoying Tang
Journal:  Theranostics       Date:  2018-11-10       Impact factor: 11.556

2.  Computational and experimental mechanical performance of a new everolimus-eluting stent purpose-built for left main interventions.

Authors:  Saurabhi Samant; Wei Wu; Shijia Zhao; Behram Khan; Mohammadali Sharzehee; Anastasios Panagopoulos; Janaki Makadia; Timothy Mickley; Andrew Bicek; Dennis Boismier; Yoshinobu Murasato; Yiannis S Chatzizisis
Journal:  Sci Rep       Date:  2021-04-22       Impact factor: 4.379

Review 3.  Recent Advances in Manufacturing Innovative Stents.

Authors:  Natalia Beshchasna; Muhammad Saqib; Honorata Kraskiewicz; Łukasz Wasyluk; Oleg Kuzmin; Oana Cristina Duta; Denisa Ficai; Zeno Ghizdavet; Alexandru Marin; Anton Ficai; Zhilei Sun; Vladimir F Pichugin; Joerg Opitz; Ecaterina Andronescu
Journal:  Pharmaceutics       Date:  2020-04-13       Impact factor: 6.321

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.