Literature DB >> 24275438

Hemodynamics in coronary arteries with overlapping stents.

Farhad Rikhtegar1, Christophe Wyss2, Kathryn S Stok3, Dimos Poulikakos1, Ralph Müller3, Vartan Kurtcuoglu4.   

Abstract

Coronary artery stenosis is commonly treated by stent placement via percutaneous intervention, at times requiring multiple stents that may overlap. Stent overlap is associated with increased risk of adverse clinical outcome. While changes in local blood flow are suspected to play a role therein, hemodynamics in arteries with overlapping stents remain poorly understood. In this study we analyzed six cases of partially overlapping stents, placed ex vivo in porcine left coronary arteries and compared them to five cases with two non-overlapping stents. The stented vessel geometries were obtained by micro-computed tomography of corrosion casts. Flow and shear stress distribution were calculated using computational fluid dynamics. We observed a significant increase in the relative area exposed to low wall shear stress (WSS<0.5 Pa) in the overlapping stent segments compared both to areas without overlap in the same samples, as well as to non-overlapping stents. We further observed that the configuration of the overlapping stent struts relative to each other influenced the size of the low WSS area: positioning of the struts in the same axial location led to larger areas of low WSS compared to alternating struts. Our results indicate that the overlap geometry is by itself sufficient to cause unfavorable flow conditions that may worsen clinical outcome. While stent overlap cannot always be avoided, improved deployment strategies or stent designs could reduce the low WSS burden.
© 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Hemodynamics; Restenosis; Stent overlap; Thrombosis; Wall shear stress

Mesh:

Year:  2013        PMID: 24275438     DOI: 10.1016/j.jbiomech.2013.10.048

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  Drug deposition in coronary arteries with overlapping drug-eluting stents.

Authors:  Farhad Rikhtegar; Elazer R Edelman; Ufuk Olgac; Dimos Poulikakos; Vartan Kurtcuoglu
Journal:  J Control Release       Date:  2016-07-16       Impact factor: 9.776

2.  Optical coherence tomography evaluation of the absorb bioresorbable scaffold performance for overlap versus non-overlap segments in patients with coronary chronic total occlusion: insight from the GHOST-CTO registry.

Authors:  Gabriel T R Pereira; Alessio La Manna; Yasuhiro Ichibori; Armando Vergara-Martel; Bruno Ramos Nascimento; Abdul Jawwad Samdani; Davide Capodanno; Guido D'Agosta; Giacomo Gravina; Giuseppe Venuti; Corrado Tamburino; Guilherme F Attizzani
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-07       Impact factor: 2.357

3.  Finite Element Analysis of the Implantation Process of Overlapping Stents.

Authors:  Jiang Xu; Jie Yang; Salman Sohrabi; Yihua Zhou; Yaling Liu
Journal:  J Med Device       Date:  2017-05-03       Impact factor: 0.582

4.  Multilayer flow modulator enhances vital organ perfusion in patients with type B aortic dissection.

Authors:  Farhad Rikhtegar Nezami; Lambros S Athanasiou; Junedh M Amrute; Elazer R Edelman
Journal:  Am J Physiol Heart Circ Physiol       Date:  2018-08-10       Impact factor: 4.733

Review 5.  Bioresorbable Scaffolds for Coronary Stenosis: When and How Based Upon Current Studies.

Authors:  Alexandre Abizaid; J Ribamar Costa
Journal:  Curr Cardiol Rep       Date:  2017-03       Impact factor: 2.931

6.  Position Paper Computational Cardiology.

Authors:  Lambros Athanasiou; Farhad Rikhtegar Nezami; Elazer R Edelman
Journal:  IEEE J Biomed Health Inform       Date:  2018-10-19       Impact factor: 5.772

7.  Optimized Computer-Aided Segmentation and Three-Dimensional Reconstruction Using Intracoronary Optical Coherence Tomography.

Authors:  Lambros Athanasiou; Farhad Rikhtegar Nezami; Micheli Zanotti Galon; Augusto Celso Lopes; Pedro Alves Lemos; Jose M de la Torre Hernandez; Eyal Ben-Assa; Elazer R Edelman
Journal:  IEEE J Biomed Health Inform       Date:  2018-07       Impact factor: 5.772

8.  Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model.

Authors:  Hong-Yang Wang; Long-Shan Liu; Hai-Ming Cao; Jun Li; Rong-Hai Deng; Qian Fu; Huan-Xi Zhang; Ji-Guang Fei; Chang-Xi Wang
Journal:  Chin Med J (Engl)       Date:  2017 5th Jan 2017       Impact factor: 2.628

9.  Effects of Low Endothelial Shear Stress After Stent Implantation on Subsequent Neointimal Hyperplasia and Clinical Outcomes in Humans.

Authors:  Koki Shishido; Antonios P Antoniadis; Saeko Takahashi; Masaya Tsuda; Shingo Mizuno; Ioannis Andreou; Michail I Papafaklis; Ahmet U Coskun; Caroline O'Brien; Charles L Feldman; Shigeru Saito; Elazer R Edelman; Peter H Stone
Journal:  J Am Heart Assoc       Date:  2016-09-14       Impact factor: 5.501

10.  Structural and Hemodynamic Analyses of Different Stent Structures in Curved and Stenotic Coronary Artery.

Authors:  Lingling Wei; Hwa Liang Leo; Qiang Chen; Zhiyong Li
Journal:  Front Bioeng Biotechnol       Date:  2019-12-06
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.