Literature DB >> 18096257

Serial angiographic and intravascular ultrasound analysis of late stent strut fracture of sirolimus-eluting stents in native coronary arteries.

Ko P Yamada1, Tomomi Koizumi, Hiroshi Yamaguchi, Hideaki Kaneda, Heidi N Bonneau, Yasuhiro Honda, Peter J Fitzgerald.   

Abstract

BACKGROUND: Stent fracture in sirolimus-eluting stents (SES) has been reported to be associated with late adverse events. However, a suitable method to diagnose stent fracture is not fully elucidated.
METHODS: One hundred and two consecutive SES implantations were performed in 83 lesions in 56 patients and underwent serial angiography with intravascular ultrasound (IVUS) at baseline and at 6 months follow-up. Angiographic stent strut fracture was defined as stent bending with separation of stent struts. Angiographic hinge movement was defined as stent shaft deviation without separation of stent struts. IVUS stent strut dissociation was defined as the disappearance of stent struts in more than one cross-sectional image which were previously visualized at baseline.
RESULTS: By angiography, no cases of stent fracture were detected at 6 months. One case of angiographic hinge movement was found at 12 months. However, three instances of stent fracture were detected by IVUS at 6 months. One case of stent fracture showed a patent lumen area at 6 months but subsequently developed late stent restenosis at 12 months. The other two cases were associated with in-stent restenosis at 6 months.
CONCLUSION: Compared to angiography, IVUS can more reliably detect stent fracture during follow-up evaluation.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18096257     DOI: 10.1016/j.ijcard.2007.08.082

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  12 in total

Review 1.  Are we aware of stent fracture?

Authors:  R D Acar; M Bulut; M Akcakoyun
Journal:  Herz       Date:  2013-10-25       Impact factor: 1.443

2.  Late stent fracture - A potential role of left ventricular dilatation.

Authors:  Ahmed Al Mamary; Gilberto Dariol; Massimo Napodano
Journal:  J Saudi Heart Assoc       Date:  2014-02-10

Review 3.  Assessment of drug-eluting stents and bioresorbable stents by grayscale IVUS and IVUS-based imaging modalities.

Authors:  Salvatore Brugaletta; Jose Ribamar Costa; Hector M Garcia-Garcia
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

4.  Impact of sirolimus-eluting stent fractures without early cardiac events on long-term clinical outcomes: a multislice computed tomography study.

Authors:  Tsuyoshi Ito; Masashi Kimura; Mariko Ehara; Mitsuyasu Terashima; Kenya Nasu; Yoshihisa Kinoshita; Maoto Habara; Etsuo Tsuchikane; Takahiko Suzuki
Journal:  Eur Radiol       Date:  2014-02-25       Impact factor: 5.315

5.  Recurrent episode of very late stent thrombosis in a patient who underwent percutaneous coronary intervention with sirolimus-eluting stent: Same or different mechanism?

Authors:  Soon Yong Suh; Woong Chol Kang; Taehoon Ahn
Journal:  J Cardiol Cases       Date:  2011-12-06

6.  Finite Element Analysis of the Implantation Process of Overlapping Stents.

Authors:  Jiang Xu; Jie Yang; Salman Sohrabi; Yihua Zhou; Yaling Liu
Journal:  J Med Device       Date:  2017-05-03       Impact factor: 0.582

Review 7.  Intravascular foreign bodies: danger of unretrieved fragmented medical devices.

Authors:  Minori Tateishi; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

8.  Fracture of zotarolimus-eluting stent after implantation.

Authors:  Meng-Chieh Wu; Chen-Chuan Cheng; Tsuei-Yuan Huang
Journal:  Tex Heart Inst J       Date:  2009

9.  Stent fracture: how frequently is it recognized?

Authors:  Mohammed Khalil Mohsen; Awad Alqahtani; Jassim Al Suwaidi
Journal:  Heart Views       Date:  2013-04

Review 10.  Coronary stent fracture: a recently appreciated phenomenon with clinical relevance.

Authors:  Madjid Chinikar; Parham Sadeghipour
Journal:  Curr Cardiol Rev       Date:  2014-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.