Literature DB >> 28673496

Optimization of Tube Current in Cone-beam Computed Tomography for the Detection of Vertical Root Fractures with Different Intracanal Materials.

Hugo Gaêta-Araujo1, Gabriela Queiroz Silva de Souza2, Deborah Queiroz Freitas1, Christiano de Oliveira-Santos3.   

Abstract

INTRODUCTION: There is no consensus about the accuracy of cone-beam computed tomography (CBCT) for detecting vertical root fractures (VRFs), nor is there certainty about the isolated effect of different tube current parameters on the diagnosis of VRF through CBCT scans. This study aimed to evaluate how tube current affects the detection of VRF on CBCT examinations in the absence of intracanal materials and in the presence of gutta-percha (GP) and metal (MP) or fiberglass (FP) intracanal posts.
METHODS: The sample consisted of 320 CBCT scans of tooth roots with and without VRF divided into 8 groups: no fracture/no intracanal material; no fracture + GP; no fracture + MP; no fracture + FP; fracture/no intracanal material; fracture + GP; fracture + MP; fracture + FP. The scans were acquired with an OP300 unit using 4 different milliamperes (4 mA, 8 mA, 10 mA, 13 mA). Five oral radiologists analyzed the images. The area under the receiver operating characteristic curve (Az), sensitivity, specificity, positive and negative predictive values, and interobserver agreement were calculated.
RESULTS: Diagnostic performance for the different milliamperes tested was similar for teeth without root filling materials or with FP. Teeth with GP and MP showed the highest Az values for 8 mA and 10 mA, respectively. For teeth with MP, specificity was significantly higher when 10 mA was used.
CONCLUSIONS: For teeth without root filling materials or with FP, the use of a reduced milliampere does not seem to influence the detection of VRF in a significant manner. For teeth with GP and MP, an increased milliampere may lead to increased diagnostic performance.
Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cone-beam computed tomography; tube current; vertical root fracture

Mesh:

Substances:

Year:  2017        PMID: 28673496     DOI: 10.1016/j.joen.2017.04.003

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  7 in total

1.  Effect of digital enhancement on the radiographic assessment of vertical root fractures in the presence of different intracanal materials: an in vitro study.

Authors:  Hugo Gaêta-Araujo; Eduarda H L Nascimento; Nicolly Oliveira-Santos; Polyane M Queiroz; Matheus L Oliveira; Deborah Q Freitas; Christiano Oliveira-Santos
Journal:  Clin Oral Investig       Date:  2020-06-06       Impact factor: 3.573

2.  Influence of sharpening filters on the detection of root fractures using low-dose cone-beam computed tomography.

Authors:  Alexandra Robles González; Guilherme Monteiro Tosoni; Deborah Queiroz Freitas; Matheus L Oliveira
Journal:  Clin Oral Investig       Date:  2022-03-15       Impact factor: 3.606

3.  Difference in the artefacts production and the performance of the metal artefact reduction (MAR) tool between the buccal and lingual cortical plates adjacent to zirconium dental implant.

Authors:  Eduarda Helena Leandro Nascimento; Rocharles Cavalcante Fontenele; Gustavo Machado Santaella; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2019-07-10       Impact factor: 2.419

4.  Artefacts at different distances from titanium and zirconia implants in cone-beam computed tomography: effect of tube current and metal artefact reduction.

Authors:  Arthur Xavier Maseti Mancini; Matheus Urias Cruz Santos; Hugo Gaêta-Araujo; Camila Tirapelli; Ruben Pauwels; Christiano Oliveira-Santos
Journal:  Clin Oral Investig       Date:  2021-02-05       Impact factor: 3.573

5.  Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures.

Authors:  Aline Pf Caetano; Thiago O Sousa; Mariana R Oliveira; Karine Evanglista; Juliano M Bueno; Maria Ag Silva
Journal:  Dentomaxillofac Radiol       Date:  2020-12-01       Impact factor: 2.419

6.  Influence of CBCT-based volumetric distortion and beam hardening artefacts on the assessment of root canal filling quality in isthmus-containing molars.

Authors:  Clarissa Teles Rodrigues; Reinhilde Jacobs; Karla Faria Vasconcelos; Paul Lambrechts; Izabel Regina Fisher Rubira-Bullen; Hugo Gaêta-Araujo; Christiano Oliveira-Santos; Marco Antonio Hungaro Duarte
Journal:  Dentomaxillofac Radiol       Date:  2021-01-05       Impact factor: 3.525

Review 7.  Present status and future directions: vertical root fractures in root filled teeth.

Authors:  Shanon Patel; Bhavin Bhuva; Rahul Bose
Journal:  Int Endod J       Date:  2022-04-15       Impact factor: 5.165

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.