OBJECTIVES: To evaluate the influence of sharpening filters in the detection of root fractures using low-dose cone-beam computed tomography (CBCT).
MATERIALS AND METHODS: Eighty-four CBCT volumes acquired at three mA levels of 28 teeth inserted in the dental socket of dry human skull were selected from a previous study. The teeth were divided into four groups according to the presence and absence of root fracture and endodontic filling. Five radiologists evaluated all CBCT volumes for the presence of root fracture with and without the application of "Sharpen 1x" and "Sharpen 2x" filters in OnDemand3D software. Area under the ROC curve (AUC), sensitivity, specificity, and inter- and intra-observer concordance were calculated and compared (α = 0.05).
RESULTS: Sharpening filters did not lead to significant differences in AUC, sensitivity, and specificity at the three mA levels tested (p > 0.05), regardless of the presence of endodontic filling (p > 0.05). However, the significant reduction of AUC observed in CBCT volumes at 4 mA without filter (p < 0.05) ceased to exist after the application of filters (p > 0.05). Sensitivity and specificity ranged from low and moderate.
CONCLUSIONS: The use of sharpening filters can be recommended in CBCT volumes at 4 mA for root fracture detection for leading to the same performance as those at 6.3 and 10 mA. The presence of endodontic filling material did not influence the action of filters in the diagnosis of root fracture. CLINICAL RELEVANCE: Sharpening filters seem to contribute to the diagnosis of root fracture in CBCT volumes acquired with reduced radiation dose.
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Cone-beam computed tomography; Diagnostic imaging; Radiographic image enhancement; Tooth fractures

Mesh:

Year:  2022        PMID: 35288809     DOI: 10.1007/s00784-022-04444-7

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.606


  27 in total

Review 1.  Cone beam computed tomography in Endodontics - a review of the literature.

Authors:  S Patel; J Brown; T Pimentel; R D Kelly; F Abella; C Durack
Journal:  Int Endod J       Date:  2019-04-09       Impact factor: 5.264

2.  Dosimetry in CBCT with Different Protocols: Emphasis on Small FOVs Including Exams for TMJ.

Authors:  Helena Aguiar Ribeiro Nascimento; Marcos Ely Almeida Andrade; Marco Antonio Gomes Frazão; Eduarda Helena Leandro Nascimento; Flavia Maria Moraes Ramos-Perez; Deborah Queiroz Freitas
Journal:  Braz Dent J       Date:  2017 Jul-Aug

Review 3.  Role of Cone-beam Computed Tomography in Diagnosis of Vertical Root Fractures: A Systematic Review and Meta-analysis.

Authors:  Sangeeta Talwar; Shivani Utneja; Ruchika Roongta Nawal; Aishwarya Kaushik; Dhirendra Srivastava; Sukhvinder Singh Oberoy
Journal:  J Endod       Date:  2016-01       Impact factor: 4.171

4.  Comparison of digital with conventional radiography in detection of vertical root fractures in endodontically treated maxillary premolars: an ex vivo study.

Authors:  Igor Tsesis; Kivanc Kamburoğlu; Alexander Katz; Aviad Tamse; Israel Kaffe; Anda Kfir
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-03-04

5.  Influence of exposure parameters on the detection of simulated root fractures in the presence of various intracanal materials.

Authors:  M G O Pinto; K A Rabelo; S L Sousa Melo; P S F Campos; L S A F Oliveira; P M Bento; D P Melo
Journal:  Int Endod J       Date:  2016-05-23       Impact factor: 5.264

6.  Comparison of intraoral radiography and cone-beam computed tomography for the detection of horizontal root fractures: an in vitro study.

Authors:  Hakan Avsever; Kaan Gunduz; Kaan Orhan; Ismail Uzun; Bilal Ozmen; Erol Egrioglu; Muhammed Midilli
Journal:  Clin Oral Investig       Date:  2013-02-09       Impact factor: 3.573

Review 7.  Cone-beam Computed Tomography for Detecting Vertical Root Fractures in Endodontically Treated Teeth: A Systematic Review.

Authors:  Edwin Chang; Ernest Lam; Prakesh Shah; Amir Azarpazhooh
Journal:  J Endod       Date:  2015-11-26       Impact factor: 4.171

8.  Optimization of Tube Current in Cone-beam Computed Tomography for the Detection of Vertical Root Fractures with Different Intracanal Materials.

Authors:  Hugo Gaêta-Araujo; Gabriela Queiroz Silva de Souza; Deborah Queiroz Freitas; Christiano de Oliveira-Santos
Journal:  J Endod       Date:  2017-06-30       Impact factor: 4.171

9.  Accuracy of High-resolution Small-volume Cone-Beam Computed Tomography in the Diagnosis of Vertical Root Fracture: An In Vivo Analysis.

Authors:  Debora R Dias; Lilian C V Iwaki; Alexandre C A de Oliveira; Felipe S Martinhão; Robson M Rossi; Maurício G Araújo; Roberto M Hayacibara
Journal:  J Endod       Date:  2020-05-15       Impact factor: 4.171

10.  A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth.

Authors:  E Brady; F Mannocci; J Brown; R Wilson; S Patel
Journal:  Int Endod J       Date:  2013-12-11       Impact factor: 5.264

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.