Literature DB >> 12097456

Effect of respiratory gating on quantifying PET images of lung cancer.

Sadek A Nehmeh1, Yusuf E Erdi, Clifton C Ling, Kenneth E Rosenzweig, Heiko Schoder, Steve M Larson, Homer A Macapinlac, Olivia D Squire, John L Humm.   

Abstract

UNLABELLED: We have developed a new technique to gate lung 18F-FDG PET images in synchronization with the respiratory motion to reduce smearing due to breathing and improve quantitation of 18F-FDG uptake in lung lesions.
METHODS: A camera-based respiratory gating system, the real-time position management (RPM), is used to monitor the respiratory cycle. The RPM provides a trigger to the PET scanner to initiate the gating cycle. Each respiratory cycle is divided into discrete bins triggered at a defined amplitude or phase within the patient's breathing motion, into which PET data are acquired. The acquired data within the time bins correspond to different lesion positions within the breathing cycle. The study includes 5 patients with lung cancer.
RESULTS: Measurements of the lesions' volumes in the gated mode showed a reduction of up to 34% compared with that of the nongated measurement. This reduction in the lesion volume has been accompanied by an increase in the intensity in the 18F-FDG signal per voxel. This finding has resulted in an improvement in measurement of the maximum standardized uptake value (SUV(max)), which increased in 1 patient by as much as 159%. The total lesion glycolysis, defined as the product of the SUV(max) and the lesion volume, was also measured in gated and nongated modes and showed a consistency between the 2 measurements.
CONCLUSION: We have shown that image smearing can be reduced by gating 18F-FDG PET images in synchronization with the respiratory motion. This technique allows a more accurate definition of the lesion volume and improves the quantitation specific activity of the tracer (in this case, 18F-FDG), which are distorted because of the breathing motion.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12097456

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  100 in total

1.  MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems.

Authors:  Nikolaos Dikaios; David Izquierdo-Garcia; Martin J Graves; Venkatesh Mani; Zahi A Fayad; Tim D Fryer
Journal:  Eur Radiol       Date:  2011-09-22       Impact factor: 5.315

2.  Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT.

Authors:  Medhat M Osman; Christian Cohade; Yuji Nakamoto; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-01-21       Impact factor: 9.236

Review 3.  PET/CT: a new imaging technology in nuclear medicine.

Authors:  Heiko Schöder; Yusuf E Erdi; Steven M Larson; Henry W D Yeung
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-05       Impact factor: 9.236

4.  Clinical utility of co-registered respiratory-gated( 99m)Tc-Technegas/MAA SPECT-CT images in the assessment of regional lung functional impairment in patients with lung cancer.

Authors:  Kazuyoshi Suga; Yasuhiko Kawakami; Mohammed Zaki; Tomio Yamashita; Kensaku Shimizu; Naofumi Matsunaga
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-06-10       Impact factor: 9.236

5.  The impact of audio-visual biofeedback on 4D PET images: results of a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Byungchul Cho; Youngho Seo; Paul J Keall
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

6.  Accelerating simultaneous algebraic reconstruction technique with motion compensation using CUDA-enabled GPU.

Authors:  Wai-Man Pang; Jing Qin; Yuqiang Lu; Yongming Xie; Chee-Kong Chui; Pheng-Ann Heng
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-06-30       Impact factor: 2.924

Review 7.  Imaging techniques for tumour delineation and heterogeneity quantification of lung cancer: overview of current possibilities.

Authors:  Wouter van Elmpt; Catharina M L Zegers; Marco Das; Dirk De Ruysscher
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

8.  Implementation of an automated respiratory amplitude gating technique for PET/CT: clinical evaluation.

Authors:  Guoping Chang; Tingting Chang; Tinsu Pan; John W Clark; Osama R Mawlawi
Journal:  J Nucl Med       Date:  2009-12-15       Impact factor: 10.057

9.  Respiratory-gated PET/CT versus delayed images for the quantitative evaluation of lower pulmonary and hepatic lesions.

Authors:  Abdel K Tahari; Martin A Lodge; Richard L Wahl
Journal:  J Med Imaging Radiat Oncol       Date:  2014-01-20       Impact factor: 1.735

10.  Motion correction of respiratory-gated PET images using deep learning based image registration framework.

Authors:  Tiantian Li; Mengxi Zhang; Wenyuan Qi; Evren Asma; Jinyi Qi
Journal:  Phys Med Biol       Date:  2020-07-30       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.