Literature DB >> 28532901

Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate.

Adam J Drelich1, Shan Zhao2, Roger J Guillory1, Jaroslaw W Drelich2, Jeremy Goldman3.   

Abstract

Metallic zinc implanted into the abdominal aorta of rats out to 6months has been demonstrated to degrade while avoiding responses commonly associated with the restenosis of vascular implants. However, major questions remain regarding whether a zinc implant would ultimately passivate through the production of stable corrosion products or via a cell mediated fibrous encapsulation process that prevents the diffusion of critical reactants and products at the metal surface. Here, we have conducted clinically relevant long term in vivo studies in order to characterize late stage zinc implant biocorrosion behavior and products to address these critical questions. We found that zinc wires implanted in the murine artery exhibit steady corrosion without local toxicity for up to at least 20months post-implantation, despite a steady buildup of passivating corrosion products and intense fibrous encapsulation of the wire. Although fibrous encapsulation was not able to prevent continued implant corrosion, it may be related to the reduced chronic inflammation observed between 10 and 20months post-implantation. X-ray elemental and infrared spectroscopy analyses confirmed zinc oxide, zinc carbonate, and zinc phosphate as the main components of corrosion products surrounding the Zn implant. These products coincide with stable phases concluded from Pourbaix diagrams of a physiological solution and in vitro electrochemical impedance tests. The results support earlier predictions that zinc stents could become successfully bio-integrated into the arterial environment and safely degrade within a time frame of approximately 1-2years. STAEMENT OF SIGNIFICANCE: Previous studies have shown zinc to be a promising candidate material for bioresorbable endovascular stenting applications. An outstanding question, however, is whether a zinc implant would ultimately passivate through the production of stable corrosion products or via a cell mediated tissue encapsulation process that prevented the diffusion of critical reactants and products at the metal surface. We found that zinc wires implanted in the murine artery exhibit steady corrosion for up to at least 20months post-implantation. The results confirm earlier predictions that zinc stents could safely degrade within a time frame of approximately 1-2years.
Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bioabsorbable; Corrosion; Stent; Zinc

Mesh:

Substances:

Year:  2017        PMID: 28532901      PMCID: PMC5553077          DOI: 10.1016/j.actbio.2017.05.045

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  46 in total

1.  In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified-simulated body fluid.

Authors:  M Bobby Kannan; R K Singh Raman
Journal:  Biomaterials       Date:  2008-03-03       Impact factor: 12.479

Review 2.  Bioabsorbable coronary stents.

Authors:  John A Ormiston; Patrick W S Serruys
Journal:  Circ Cardiovasc Interv       Date:  2009-06       Impact factor: 6.546

3.  A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials.

Authors:  Daniel Pierson; Jacob Edick; Aaron Tauscher; Ellen Pokorney; Patrick Bowen; Jesse Gelbaugh; Jon Stinson; Heather Getty; Chee Huei Lee; Jaroslaw Drelich; Jeremy Goldman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2011-09-08       Impact factor: 3.368

Review 4.  Zinc transport in mammalian cells.

Authors:  J G Reyes
Journal:  Am J Physiol       Date:  1996-02

5.  Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial.

Authors:  Michael Haude; Hüseyin Ince; Alexandre Abizaid; Ralph Toelg; Pedro Alves Lemos; Clemens von Birgelen; Evald Høj Christiansen; William Wijns; Franz-Josef Neumann; Christoph Kaiser; Eric Eeckhout; Soo Teik Lim; Javier Escaned; Hector M Garcia-Garcia; Ron Waksman
Journal:  Lancet       Date:  2015-10-12       Impact factor: 79.321

6.  Initial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans.

Authors:  H Tamai; K Igaki; E Kyo; K Kosuga; A Kawashima; S Matsui; H Komori; T Tsuji; S Motohara; H Uehata
Journal:  Circulation       Date:  2000-07-25       Impact factor: 29.690

7.  Zn-Li alloy after extrusion and drawing: Structural, mechanical characterization, and biodegradation in abdominal aorta of rat.

Authors:  Shan Zhao; Jan-M Seitz; Rainer Eifler; Hans J Maier; Roger J Guillory; Elisha J Earley; Adam Drelich; Jeremy Goldman; Jaroslaw W Drelich
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2017-03-11       Impact factor: 7.328

8.  Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial.

Authors:  Michael Haude; Raimund Erbel; Paul Erne; Stefan Verheye; Hubertus Degen; Dirk Böse; Paul Vermeersch; Inge Wijnbergen; Neil Weissman; Francesco Prati; Ron Waksman; Jacques Koolen
Journal:  Lancet       Date:  2013-03-09       Impact factor: 79.321

9.  A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators.

Authors:  D L Fischman; M B Leon; D S Baim; R A Schatz; M P Savage; I Penn; K Detre; L Veltri; D Ricci; M Nobuyoshi
Journal:  N Engl J Med       Date:  1994-08-25       Impact factor: 91.245

10.  A surface-eroding poly(1,3-trimethylene carbonate) coating for fully biodegradable magnesium-based stent applications: toward better biofunction, biodegradation and biocompatibility.

Authors:  Juan Wang; Yonghui He; Manfred F Maitz; Boyce Collins; Kaiqin Xiong; Lisha Guo; Yeoheung Yun; Guojiang Wan; Nan Huang
Journal:  Acta Biomater       Date:  2013-03-01       Impact factor: 8.947

View more
  17 in total

1.  Novel Zinc / Tungsten Carbide Nanocomposite as Bioabsorbable Implant.

Authors:  Zeyi Guan; Chase S Linsley; Injoo Hwang; Gongcheng Yao; Benjamin M Wu; Xiaochun Li
Journal:  Mater Lett       Date:  2019-12-28       Impact factor: 3.423

Review 2.  Zinc-based alloys for degradable vascular stent applications.

Authors:  Ehsan Mostaed; Malgorzata Sikora-Jasinska; Jaroslaw W Drelich; Maurizio Vedani
Journal:  Acta Biomater       Date:  2018-03-10       Impact factor: 8.947

3.  Systematical evolution on a Zn-Mg alloy potentially developed for biodegradable cardiovascular stents.

Authors:  Song Lin; Xiaolin Ran; Xinhao Yan; Qilong Wang; Jack G Zhou; Tingzhang Hu; Guixue Wang
Journal:  J Mater Sci Mater Med       Date:  2019-11-01       Impact factor: 3.896

Review 4.  Advances and perspective on the translational medicine of biodegradable metals.

Authors:  Hongtao Yang; Wenjiao Lin; Yufeng Zheng
Journal:  Biomater Transl       Date:  2021-09-28

5.  Zn-Mg-WC Nanocomposites for Bioresorbable Cardiovascular Stents: Microstructure, Mechanical Properties, Fatigue, Shelf Life, and Corrosion.

Authors:  Zeyi Guan; Chase S Linsley; Shuaihang Pan; Gongcheng Yao; Benjamin M Wu; Daniel S Levi; Xiaochun Li
Journal:  ACS Biomater Sci Eng       Date:  2021-12-29

6.  Improved biocompatibility of Zn-Ag-based stent materials by microstructure refinement.

Authors:  Roger J Guillory; Ehsan Mostaed; Alexander A Oliver; Lea M Morath; Elisha J Earley; Katie L Flom; Timothy M Kolesar; Ali Mostaed; Henry D Summers; Maria P Kwesiga; Jaroslaw W Drelich; Kent D Carlson; Dan Dragomir-Daescu; Jeremy Goldman
Journal:  Acta Biomater       Date:  2022-03-31       Impact factor: 10.633

Review 7.  Bioresorbable Scaffold-Based Controlled Drug Delivery for Restenosis.

Authors:  Belay Tesfamariam
Journal:  J Cardiovasc Transl Res       Date:  2018-10-26       Impact factor: 4.132

Review 8.  Updates on the research and development of absorbable metals for biomedical applications.

Authors:  Hendra Hermawan
Journal:  Prog Biomater       Date:  2018-05-22

9.  Initial formation of corrosion products on pure zinc in saline solution.

Authors:  Yao Meng; Lijun Liu; Dawei Zhang; Chaofang Dong; Yu Yan; Alex A Volinsky; Lu-Ning Wang
Journal:  Bioact Mater       Date:  2018-10-11

Review 10.  Recent Advances in Manufacturing Innovative Stents.

Authors:  Natalia Beshchasna; Muhammad Saqib; Honorata Kraskiewicz; Łukasz Wasyluk; Oleg Kuzmin; Oana Cristina Duta; Denisa Ficai; Zeno Ghizdavet; Alexandru Marin; Anton Ficai; Zhilei Sun; Vladimir F Pichugin; Joerg Opitz; Ecaterina Andronescu
Journal:  Pharmaceutics       Date:  2020-04-13       Impact factor: 6.321

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.