Literature DB >> 28429120

The influence of pump rotation speed on hemodynamics and myocardial oxygen metabolism in left ventricular assist device support with aortic valve regurgitation.

Kei Iizuka1,2, Tomohiro Nishinaka3, Yoshiaki Takewa4, Kenji Yamazaki3, Eisuke Tatsumi4.   

Abstract

Aortic valve regurgitation (AR) is a serious complication under left ventricular assist device (LVAD) support. AR causes LVAD-left ventricular (LV) recirculation, which makes it difficult to continue LVAD support. However, the hemodynamics and myocardial oxygen metabolism of LVAD support with AR have not been clarified, especially, how pump rotation speed influences them. An animal model of LVAD with AR was newly developed, and how pump rotation speed influences hemodynamics and myocardial oxygen metabolism was examined in acute animal experiments. Five goats (55 ± 9.3 kg) underwent centrifugal type LVAD, EVAHEART implantation. The AR model was established by placing a vena cava filter in the aortic valve. Hemodynamic values and the myocardial oxygen consumption, delivery, and oxygen extraction ratio (O2ER) were evaluated with changing pump rotation speeds with or without AR (AR+, AR-). AR+ was defined as Sellers classification 3 or greater. AR was successfully induced in five goats. Diastolic aortic pressure was significantly lower in AR+ than AR- (p = 0.026). Central venous pressure, mean left atrial pressure, and diastolic left ventricular pressure were significantly higher in AR+ than AR- (p = 0.010, 0.047, and 0.0083, respectively). Although systemic flow did not improve with increasing pump rotation speed, LVAD pump flow increased over systemic flow in AR+, which meant increasing pump rotation speed increased LVAD-LV recirculation and did not contribute to effective systemic circulation. O2ER in AR- decreased with increasing pump rotation speed, but O2ER in AR+ was hard to decrease. The O2ER in AR+ correlated positively with the flow rate of LVAD-LV recirculation (p = 0.012). AR caused LVAD-LV recirculation that interfered with the cardiac assistance of LVAD support and made it ineffective to manage with high pump rotation speed.

Entities:  

Keywords:  Aortic valve regurgitation; Large animal experiment; Pump rotation speed; Recirculation; Ventricular assist devise

Mesh:

Substances:

Year:  2017        PMID: 28429120     DOI: 10.1007/s10047-017-0960-y

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  9 in total

1.  Completely pulsatile high flow circulatory support with a constant-speed centrifugal blood pump: mechanisms and early clinical observations.

Authors:  Kenji Yamazaki; Satoshi Saito; Shinichiro Kihara; Osamu Tagusari; Hiromi Kurosawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2007-04

2.  Late aortic insufficiency related to poor prognosis during left ventricular assist device support.

Authors:  Koichi Toda; Tomoyuki Fujita; Keitaro Domae; Yusuke Shimahara; Junjiro Kobayashi; Takeshi Nakatani
Journal:  Ann Thorac Surg       Date:  2011-09       Impact factor: 4.330

3.  EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.

Authors:  Kenji Yamazaki; Shinichiro Kihara; Takehide Akimoto; Osamu Tagusari; Akihiko Kawai; Mitsuo Umezu; Jun Tomioka; Robert L Kormos; Bartley P Griffith; Hiromi Kurosawa
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2002-11

4.  The development of aortic insufficiency in left ventricular assist device-supported patients.

Authors:  Jennifer Cowger; Francis D Pagani; Jonathan W Haft; Matthew A Romano; Keith D Aaronson; Theodore J Kolias
Journal:  Circ Heart Fail       Date:  2010-08-25       Impact factor: 8.790

5.  Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices.

Authors:  Sang-Woo Pak; Nir Uriel; Hiroo Takayama; Sarah Cappleman; Robert Song; Paolo C Colombo; Sandy Charles; Donna Mancini; Linda Gillam; Yoshifumi Naka; Ulrich P Jorde
Journal:  J Heart Lung Transplant       Date:  2010-07-08       Impact factor: 10.247

6.  Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device.

Authors:  Masaru Hatano; Koichiro Kinugawa; Taro Shiga; Naoko Kato; Miyoko Endo; Motoyuki Hisagi; Takashi Nishimura; Atsushi Yao; Yasunobu Hirata; Shunei Kyo; Minoru Ono; Ryozo Nagai
Journal:  Circ J       Date:  2011-03-03       Impact factor: 2.993

7.  What Is the Optimal Setting for a Continuous-Flow Left Ventricular Assist Device in Severe Mitral Regurgitation?

Authors:  Noritsugu Naito; Takashi Nishimura; Yoshiaki Takewa; Satoru Kishimoto; Kazuma Date; Akihide Umeki; Masahiko Ando; Minoru Ono; Eisuke Tatsumi
Journal:  Artif Organs       Date:  2016-05-19       Impact factor: 3.094

8.  Investigation of the freely available easy-to-use software 'EZR' for medical statistics.

Authors:  Y Kanda
Journal:  Bone Marrow Transplant       Date:  2012-12-03       Impact factor: 5.483

9.  Aortic valve closure for rapidly deteriorated aortic insufficiency after continuous flow left ventricular assist device implantation.

Authors:  Tomoyuki Fujita; Junjiro Kobayashi; Hiroki Hata; Osamu Seguchi; Takuma Sato; Masanobu Yanase; Yoshihiro Murata; Haruki Sunami; Takeshi Nakatani
Journal:  J Artif Organs       Date:  2012-09-18       Impact factor: 1.731

  9 in total
  7 in total

1.  Left heart pressures can be the key to know the limitation of left ventricular assist device support against progression of aortic insufficiency.

Authors:  Kei Iizuka; Tomohiro Nishinaka; Noritsugu Naito; Daichi Akiyama; Yoshiaki Takewa; Kenji Yamazaki; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2018-02-20       Impact factor: 1.731

Review 2.  Clinical implications of hemodynamic assessment during left ventricular assist device therapy.

Authors:  Teruhiko Imamura; Ben Chung; Ann Nguyen; Gabriel Sayer; Nir Uriel
Journal:  J Cardiol       Date:  2017-12-26       Impact factor: 3.159

3.  The angle of the outflow graft to the aorta can affect recirculation due to aortic insufficiency under left ventricular assist device support.

Authors:  Kei Iizuka; Tomohiro Nishinaka; Daichi Akiyama; Hirohito Sumikura; Toshihide Mizuno; Tomonori Tsukiya; Yoshiaki Takewa; Kenji Yamazaki; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2018-07-23       Impact factor: 1.731

4.  Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support.

Authors:  Kei Iizuka; Tomohiro Nishinaka; Yuki Ichihara; Takuma Miyamoto; Kenji Yamazaki
Journal:  J Artif Organs       Date:  2017-11-21       Impact factor: 1.731

5.  Relationship between myocardial oxygenation and blood pressure: Experimental validation using oxygenation-sensitive cardiovascular magnetic resonance.

Authors:  Dominik P Guensch; Kady Fischer; Christof Jung; Samuel Hurni; Bernhard M Winkler; Bernd Jung; Andreas P Vogt; Balthasar Eberle
Journal:  PLoS One       Date:  2019-01-16       Impact factor: 3.240

Review 6.  Journal of Artificial Organs 2017: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; G Matsumiya; K Matsuda; E Tatsumi; T Abe; K Fukunaga; S Ichiba; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2018-02-09       Impact factor: 1.731

7.  Comparative analysis of cardiac mechano-energetics in isolated hearts supported by pulsatile or rotary blood pumps.

Authors:  Marcus Granegger; Young Choi; Benedikt Locher; Philipp Aigner; Emanuel J Hubmann; Frithjof Lemme; Nikola Cesarovic; Michael Hübler; Martin Schweiger
Journal:  Sci Rep       Date:  2019-12-27       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.