Left heart pressures can be the key to know the limitation of left ventricular assist device support against progression of aortic insufficiency.

Kei Iizuka1,2, Tomohiro Nishinaka3, Noritsugu Naito4, Daichi Akiyama4, Yoshiaki Takewa4, Kenji Yamazaki3, Eisuke Tatsumi4.   

Abstract

Aortic insufficiency (AI) is a worrisome complication under left ventricular assist device (LVAD) support. AI progression causes LVAD-left ventricular (LV) recirculation and can require surgical intervention to the aortic valve. However, the limitations of LVAD support are not well known. Using an animal model of LVAD with AI, the effect of AI progression on hemodynamics and myocardial oxygen metabolism were investigated. Five goats (Saanen 48 ± 2 kg) underwent centrifugal type LVAD, EVAHEART, implantation. The AI model was established by placing a vena cava filter in the aortic valve. Cardiac dysfunction was induced by continuous beta-blockade (esmolol) infusion. Hemodynamic values and myocardial oxygen extraction ratio (O2ER) were evaluated while changing the degree of AI which was expressed as the flow rate of LVAD-LV recirculation (recirculation rate). Diastolic aortic pressure was decreased with AI progression and correlated negatively with the recirculation rate (p = 0.00055). Systolic left ventricular pressure (LVP) and mean left atrial pressure (LAP) were increased with AI progression and correlated positively with the recirculation rate (p = 0.010, 0.023, respectively). LVP and LAP showed marked exponential increases when the recirculation rate surpassed 40%. O2ER was also increased with AI progression and had a significant positive correlation with the recirculation rate (p = 0.000043). O2ER was increased linearly, with no exponential increase. AI progression made it difficult to reduce the cardiac pressure load, worsening myocardial oxygen metabolism. The exponential increase of left heart pressures could be the key to know the limitation of LVAD support against AI progression.

Entities:  

Keywords:  Aortic Insufficiency; Hemodynamics; Large animal experiment; Left ventricular assist device; Recirculation

Mesh:

Year:  2018        PMID: 29464441     DOI: 10.1007/s10047-018-1027-4

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  12 in total

1.  Coronary hemodynamics and myocardial oxygen consumption during support with rotary blood pumps.

Authors:  Peter Voitl; Michael Vollkron; Helga Bergmeister; Georg Wieselthaler; Heinrich Schima
Journal:  Artif Organs       Date:  2009-01       Impact factor: 3.094

2.  De novo aortic regurgitation after continuous-flow left ventricular assist device implantation.

Authors:  Nikhil Prakash Patil; Anton Sabashnikov; Prashant N Mohite; Diana Garcia; Alexander Weymann; Bartlomiej Zych; Christopher T Bowles; Rachel Hards; Michael Hedger; Aron F Popov; Fabio De Robertis; Ajay Moza; Toufan Bahrami; Mohamed Amrani; Shelley Rahman-Haley; Nicholas R Banner; André Rüdiger Simon
Journal:  Ann Thorac Surg       Date:  2014-07-25       Impact factor: 4.330

Review 3.  Comprehensive review and suggested strategies for the detection and management of aortic insufficiency in patients with a continuous-flow left ventricular assist device.

Authors:  Jennifer Cowger; Vivek Rao; Todd Massey; Benjamin Sun; Karen May-Newman; Ulrich Jorde; Jerry D Estep
Journal:  J Heart Lung Transplant       Date:  2014-10-24       Impact factor: 10.247

4.  The influence of pump rotation speed on hemodynamics and myocardial oxygen metabolism in left ventricular assist device support with aortic valve regurgitation.

Authors:  Kei Iizuka; Tomohiro Nishinaka; Yoshiaki Takewa; Kenji Yamazaki; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2017-04-20       Impact factor: 1.731

5.  EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.

Authors:  Kenji Yamazaki; Shinichiro Kihara; Takehide Akimoto; Osamu Tagusari; Akihiko Kawai; Mitsuo Umezu; Jun Tomioka; Robert L Kormos; Bartley P Griffith; Hiromi Kurosawa
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2002-11

6.  Central aortic valve closure successfully treated aortic insufficiency of the patient with Jarvik 2000 continuous flow left ventricular assist device: a case report.

Authors:  Yoshifumi Itoda; Kan Nawata; Haruo Yamauchi; Osamu Kinoshita; Mitsutoshi Kimura; Minoru Ono
Journal:  J Artif Organs       Date:  2016-10-15       Impact factor: 1.731

7.  The development of aortic insufficiency in left ventricular assist device-supported patients.

Authors:  Jennifer Cowger; Francis D Pagani; Jonathan W Haft; Matthew A Romano; Keith D Aaronson; Theodore J Kolias
Journal:  Circ Heart Fail       Date:  2010-08-25       Impact factor: 8.790

8.  Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices.

Authors:  Sang-Woo Pak; Nir Uriel; Hiroo Takayama; Sarah Cappleman; Robert Song; Paolo C Colombo; Sandy Charles; Donna Mancini; Linda Gillam; Yoshifumi Naka; Ulrich P Jorde
Journal:  J Heart Lung Transplant       Date:  2010-07-08       Impact factor: 10.247

9.  Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device.

Authors:  Masaru Hatano; Koichiro Kinugawa; Taro Shiga; Naoko Kato; Miyoko Endo; Motoyuki Hisagi; Takashi Nishimura; Atsushi Yao; Yasunobu Hirata; Shunei Kyo; Minoru Ono; Ryozo Nagai
Journal:  Circ J       Date:  2011-03-03       Impact factor: 2.993

10.  Investigation of the freely available easy-to-use software 'EZR' for medical statistics.

Authors:  Y Kanda
Journal:  Bone Marrow Transplant       Date:  2012-12-03       Impact factor: 5.483

View more
  2 in total

Review 1.  Journal of Artificial Organs 2018: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; G Matsumiya; K Matsuda; E Tatsumi; T Abe; K Fukunaga; S Ichiba; T Taguchi; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2019-02-23       Impact factor: 1.731

2.  The angle of the outflow graft to the aorta can affect recirculation due to aortic insufficiency under left ventricular assist device support.

Authors:  Kei Iizuka; Tomohiro Nishinaka; Daichi Akiyama; Hirohito Sumikura; Toshihide Mizuno; Tomonori Tsukiya; Yoshiaki Takewa; Kenji Yamazaki; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2018-07-23       Impact factor: 1.731

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.