Literature DB >> 22986540

Aortic valve closure for rapidly deteriorated aortic insufficiency after continuous flow left ventricular assist device implantation.

Tomoyuki Fujita1, Junjiro Kobayashi, Hiroki Hata, Osamu Seguchi, Takuma Sato, Masanobu Yanase, Yoshihiro Murata, Haruki Sunami, Takeshi Nakatani.   

Abstract

A patient underwent aortic valve closure for de novo aortic insufficiency that had deteriorated to severe insufficiency during six months of support with a continuous flow left ventricular assist device (cf-LVAD). Aortic insufficiency was initially noted one month after LVAD implantation, and then deterioration quickly developed. Right heart catheterization revealed that when the rotational speed of the cf-LVAD was increased, the cardiac index was decreased by an increase in regurgitant volume, as shown by echocardiography. During surgery, fusion and shortening of the aortic leaflets as well as left coronary ostial occlusion were observed. Direct aortic closure improved hemodynamics. Thrombus formation on the aortic valve shown by echocardiography in the early postoperative period may be a trigger of aortic insufficiency. Control of the cf-LVAD rotational speed is likely required to prevent aortic insufficiency.

Entities:  

Mesh:

Year:  2012        PMID: 22986540     DOI: 10.1007/s10047-012-0661-5

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  7 in total

Review 1.  Thrombosis and acute coronary syndrome.

Authors:  Rosanna Abbate; Gabriele Cioni; Ilaria Ricci; Marco Miranda; Anna Maria Gori
Journal:  Thromb Res       Date:  2012-01-24       Impact factor: 3.944

2.  Aortic valve procedures at the time of ventricular assist device placement.

Authors:  Ayumi Goda; Hiroo Takayama; Sang-Woo Pak; Nir Uriel; Donna Mancini; Yoshifumi Naka; Ulrich P Jorde
Journal:  Ann Thorac Surg       Date:  2011-03       Impact factor: 4.330

3.  Late aortic insufficiency related to poor prognosis during left ventricular assist device support.

Authors:  Koichi Toda; Tomoyuki Fujita; Keitaro Domae; Yusuke Shimahara; Junjiro Kobayashi; Takeshi Nakatani
Journal:  Ann Thorac Surg       Date:  2011-09       Impact factor: 4.330

4.  Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices.

Authors:  Sang-Woo Pak; Nir Uriel; Hiroo Takayama; Sarah Cappleman; Robert Song; Paolo C Colombo; Sandy Charles; Donna Mancini; Linda Gillam; Yoshifumi Naka; Ulrich P Jorde
Journal:  J Heart Lung Transplant       Date:  2010-07-08       Impact factor: 10.247

5.  Aortic valve closure associated with HeartMate left ventricular device support: technical considerations and long-term results.

Authors:  Robert M Adamson; Walter P Dembitsky; Sam Baradarian; Joseph Chammas; Karen May-Newman; Suzanne Chillcott; Marcia Stahovich; Vicki McCalmont; Kristi Ortiz; Peter Hoagland; Brian Jaski
Journal:  J Heart Lung Transplant       Date:  2011-01-22       Impact factor: 10.247

6.  Surgical closure of left ventricular outflow tract after left ventricular assist device implantation in patients with aortic valve pathology.

Authors:  William E Cohn; Zumrut T Demirozu; O H Frazier
Journal:  J Heart Lung Transplant       Date:  2010-09-29       Impact factor: 10.247

7.  Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device.

Authors:  James O Mudd; Jonathan D Cuda; Marc Halushka; Karl A Soderlund; John V Conte; Stuart D Russell
Journal:  J Heart Lung Transplant       Date:  2008-10-26       Impact factor: 10.247

  7 in total
  6 in total

Review 1.  Simultaneous procedures during left ventricular assist device implantation: is less always more?

Authors:  Nikhil Jaik; Robert S D Higgins; Bryan A Whitson
Journal:  Curr Heart Fail Rep       Date:  2014-03

2.  The influence of pump rotation speed on hemodynamics and myocardial oxygen metabolism in left ventricular assist device support with aortic valve regurgitation.

Authors:  Kei Iizuka; Tomohiro Nishinaka; Yoshiaki Takewa; Kenji Yamazaki; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2017-04-20       Impact factor: 1.731

3.  Left coronary artery occlusion caused by a large thrombus on the left coronary cusp in a patient with a continuous-flow ventricular assist device.

Authors:  Seiko Nakajima; Osamu Seguchi; Yoshihiro Murata; Tomoyuki Fujita; Hiroki Hata; Takafumi Yamane; Michinari Hieda; Takuya Watanabe; Takuma Sato; Haruki Sunami; Masanobu Yanase; Junjiro Kobayashi; Takeshi Nakatani
Journal:  J Artif Organs       Date:  2014-02-08       Impact factor: 1.731

Review 4.  Journal of Artificial Organs 2013: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; E Tatsumi; T Tsukiya; K Matsuda; K Fukunaga; A Kishida; T Masuzawa; G Matsumiya; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2014-02-26       Impact factor: 1.731

5.  Early and mid-term outcomes of left ventricular assist device implantation and future prospects.

Authors:  Hiroki Hata; Tomoyuki Fujita; Yusuke Shimahara; Shunsuke Sato; Masanobu Yanase; Osamu Seguchi; Takuma Sato; Takeshi Nakatani; Junjiro Kobayashi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-03-24

6.  The angle of the outflow graft to the aorta can affect recirculation due to aortic insufficiency under left ventricular assist device support.

Authors:  Kei Iizuka; Tomohiro Nishinaka; Daichi Akiyama; Hirohito Sumikura; Toshihide Mizuno; Tomonori Tsukiya; Yoshiaki Takewa; Kenji Yamazaki; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2018-07-23       Impact factor: 1.731

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.