Modeling Shift-Variant X-Ray Focal Spot Blur for High-Resolution Flat-Panel Cone-Beam CT.

Steven Tilley1, Wojciech Zbijewski1, Jeffrey H Siewerdsen1, J Webster Stayman1.   

Abstract

Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We present a shift-variant focal-spot blur model and incorporate it into a model-based iterative-reconstruction algorithm. We apply this algorithm to simulation and CBCT test-bench data. In a trabecular bone simulation study, we find traditional reconstruction approaches without a blur model exhibit shift-variant resolution properties that depend greatly on the acquisition protocol (e.g. short vs. full scans) and the anode angles of the rays used to reconstruct a particular region. For physical CBCT experiments focal spot blur was characterized and a spatial resolution phantom was scanned and reconstructed. In both experiments image quality using the shift-variant model was significantly improved over approaches that modeled no blur or only a shift-invariant blur, suggesting a potential means to overcome traditional CBCT spatial resolution and system design limitations.

Entities:  

Year:  2016        PMID: 28361129      PMCID: PMC5370169     

Source DB:  PubMed          Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr


  6 in total

1.  Monotonic algorithms for transmission tomography.

Authors:  H Erdoğan; J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1999-09       Impact factor: 10.048

2.  Correction for resolution nonuniformities caused by anode angulation in computed tomography.

Authors:  Patrick J La Rivière; Phillip Vargas
Journal:  IEEE Trans Med Imaging       Date:  2008-09       Impact factor: 10.048

3.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

4.  Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

Authors:  J H Siewerdsen; L E Antonuk; Y el-Mohri; J Yorkston; W Huang; I A Cunningham
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

5.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

6.  Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2015-12-09       Impact factor: 3.609

  6 in total
  4 in total

1.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

2.  Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.

Authors:  Qian Cao; Alejandro Sisniega; Michael Brehler; J Webster Stayman; John Yorkston; Jeffrey H Siewerdsen; Wojciech Zbijewski
Journal:  Med Phys       Date:  2017-11-27       Impact factor: 4.071

3.  Blind deconvolution in model-based iterative reconstruction for CT using a normalized sparsity measure.

Authors:  Lorenz Hehn; Steven Tilley; Franz Pfeiffer; J Webster Stayman
Journal:  Phys Med Biol       Date:  2019-10-31       Impact factor: 3.609

4.  Predicting image properties in penalized-likelihood reconstructions of flat-panel CBCT.

Authors:  Wenying Wang; Grace J Gang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Med Phys       Date:  2018-11-20       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.