Literature DB >> 28303395

Movement of steel-jacketed projectiles in biological tissue in the magnetic field of a 3-T magnetic resonance unit.

Stephan A Bolliger1, Michael J Thali2, Dominic Gascho2, Sebastian A Poschmann2, Sebastian Eggert2.   

Abstract

PURPOSE: The fact that ferromagnetic bullets can move in air or gelatine when subjected to magnetic resonance (MR) units is well known. A previous study showed that the movement of 7.5-mm GP 11 Suisse bullets also depends on their orientation toward the gantry. In order to compare the movement in gelatine to that in real tissue, we decided to measure the movement of these bullets, as well as 9-mm Luger bullets, in the brain and liver.
METHODS: The GP 11 and 9-mm Luger bullets were inserted into the fresh calf brain or pig liver either vertically or horizontally in the x- or z-axis to the gantry. Before and after exposure to a 3-T MR unit, their position was documented by CT.
RESULTS: GP 11 bullets rotated more readily and in general proved to be more mobile than the 9-mm Luger. All GP 11 bullets and a large amount of the 9-mm Luger bullets exited the brain. Sliding toward the gantry was easier for 9-mm Luger bullets in the brain than in the liver.
CONCLUSIONS: The orientation of a ferromagnetic object influences its mobility in a strong magnetic field. Tipping is easier than sliding for longish ferromagnetic projectiles, probably due to the lesser tissue resistance. The bullets moved more readily in biological tissue, especially brain tissue, compared to gelatine, thus implying that gelatine is not a suitable substitute for soft tissues when examining the movement of ferromagnetic objects in MR units.

Entities:  

Keywords:  Biological tissue; Bullets; Ferromagnetic foreign bodies; MR; MR safety

Mesh:

Substances:

Year:  2017        PMID: 28303395     DOI: 10.1007/s00414-017-1574-x

Source DB:  PubMed          Journal:  Int J Legal Med        ISSN: 0937-9827            Impact factor:   2.686


  21 in total

1.  Metallic neurosurgical implants: evaluation of magnetic field interactions, heating, and artifacts at 1.5-Tesla.

Authors:  F G Shellock
Journal:  J Magn Reson Imaging       Date:  2001-09       Impact factor: 4.813

2.  The influence of 1.5 and 3 T magnetic resonance unit magnetic fields on the movement of steel-jacketed projectiles in ordnance gelatin.

Authors:  Sebastian Eggert; Rahel A Kubik-Huch; Martin Lory; John M Froehlich; Dominic Gascho; Michael J Thali; Stephan A Bolliger
Journal:  Forensic Sci Med Pathol       Date:  2015-10-30       Impact factor: 2.007

3.  Ballistic skin simulant.

Authors:  Jorma Jussila; Ari Leppäniemi; Mikael Paronen; Erkki Kulomäki
Journal:  Forensic Sci Int       Date:  2005-05-28       Impact factor: 2.395

4.  Safety of orthopedic implants in magnetic resonance imaging: an experimental verification.

Authors:  Ritabh Kumar; Richard A Lerski; Stephen Gandy; Benedict A Clift; Rami J Abboud
Journal:  J Orthop Res       Date:  2006-09       Impact factor: 3.494

5.  Armor-piercing bullet: 3-T MRI findings and identification by a ferromagnetic detection system.

Authors:  Alexandra M Karacozoff; Murat Pekmezci; Frank G Shellock
Journal:  Mil Med       Date:  2013-03       Impact factor: 1.437

6.  The 'triple contrast' method in experimental wound ballistics and backspatter analysis.

Authors:  Christian Schyma; Constantin Lux; Burkhard Madea; Cornelius Courts
Journal:  Int J Legal Med       Date:  2015-01-24       Impact factor: 2.686

7.  Deep Into the Fibers! Postmortem Diffusion Tensor Imaging in Forensic Radiology.

Authors:  Patricia Mildred Flach; Sarah Schroth; Wolf Schweitzer; Garyfalia Ampanozi; Johannes Slotboom; Claus Kiefer; Tanja Germerott; Michael J Thali; Marwan El-Koussy
Journal:  Am J Forensic Med Pathol       Date:  2015-09       Impact factor: 0.921

8.  MRI issues for ballistic objects: information obtained at 1.5-, 3- and 7-Tesla.

Authors:  Russell D Dedini; Alexandra M Karacozoff; Frank G Shellock; Duan Xu; R Trigg McClellan; Murat Pekmezci
Journal:  Spine J       Date:  2013-04-03       Impact factor: 4.166

9.  Magnetic Field Interactions of Military and Law Enforcement Bullets at 1.5 and 3 Tesla.

Authors:  Idris Diallo; Mathieu Auffret; Lakdar Attar; Elise Bouvard; Jean Rousset; Douraied Ben Salem
Journal:  Mil Med       Date:  2016-07       Impact factor: 1.437

10.  High-speed documented experimental gunshot to a skull-brain model and radiologic virtual autopsy.

Authors:  Michael J Thali; Beat P Kneubuehl; Peter Vock; Gabriel v Allmen; Richard Dirnhofer
Journal:  Am J Forensic Med Pathol       Date:  2002-09       Impact factor: 0.921

View more
  2 in total

1.  Synergy of CT and MRI in detecting trajectories of lodged bullets in decedents and potential hazards concerning the heating and movement of bullets during MRI.

Authors:  Dominic Gascho; Carlo Tappero; Niklaus Zoelch; Eva Deininger-Czermak; Henning Richter; Michael J Thali; Sarah Schaerli
Journal:  Forensic Sci Med Pathol       Date:  2019-11-25       Impact factor: 2.007

Review 2.  Neurosurgical Care of Nonpowder Firearm Injuries: A Narrative Review of the Literature.

Authors:  Yizhou Wan; Stewart Griffiths; Mario Ganau
Journal:  Emerg Med Int       Date:  2019-11-20       Impact factor: 1.112

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.