Ultrasound findings in asymptomatic patients with modular metal on metal total hip arthroplasty.

Nicholas B Frisch1, Nolan M Wessell2, Kevin Taliaferro2, Marnix Van Holsbeeck3, Craig D Silverton2.   

Abstract

OBJECTIVE: The use of metal-on-metal and modular total hip arthroplasty is associated with potentially serious local and systemic complications. The primary aim of this study was to identify the prevalence of a pseudotumor in asymptomatic patients with a particular metal-on-metal hip prosthesis after a minimum follow-up of 5 years using ultrasound evaluation. A secondary purpose was to identify associations between the presence of pseudotumor and serum metal ion levels following implantation.
METHODS: We prospectively evaluated data collected from 36 asymptomatic patients who underwent implantation of a Profemur Z metal-on-metal total hip arthroplasty from January 2004 to January 2010. Serum metal ion levels were collected in 2012 and 2015. Hip ultrasounds were performed in 2015.
RESULTS: Pseudotumors were found in 7/36 patients (19.4%). The average pseudotumor size measured 38.2 cm3 (range 7.35 cm3-130.81 cm3). Elevated metal ion levels were found in all patients at all time points. No statistical correlation was found between the presence of pseudotumor and patient age, age of the implant, component design, and any of the serum metal ion levels or ratios.
CONCLUSIONS: One in every five asymptomatic patients with metal-on-metal implants was found to have a periarticular pseudotumor. There was no dose-dependent relationship found between elevated serum metal ion levels and the development of a pseudotumor. Our findings suggest that in patients with known elevated metal ion levels, continued monitoring of ion levels may not be a reliable predictor of pseudotumor formation, and ultrasound surveillance can and should be routinely used to document the presence and progression of pseudotumor.

Entities:  

Keywords:  Metal-on-metal; Profemur Z; Pseudotumor; Total hip arthroplasty; Ultrasound

Mesh:

Substances:

Year:  2017        PMID: 28204856     DOI: 10.1007/s00256-017-2592-y

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  38 in total

1.  Serum cobalt levels after metal-on-metal total hip arthroplasty.

Authors:  Wolfram Brodner; Peter Bitzan; Vanee Meisinger; Alexandra Kaider; Florian Gottsauner-Wolf; Rainer Kotz
Journal:  J Bone Joint Surg Am       Date:  2003-11       Impact factor: 5.284

2.  Arthroprosthetic cobaltism: neurological and cardiac manifestations in two patients with metal-on-metal arthroplasty: a case report.

Authors:  Stephen S Tower
Journal:  J Bone Joint Surg Am       Date:  2010-10-29       Impact factor: 5.284

3.  Systemic metal exposure in large- and small-diameter metal-on-metal total hip replacements.

Authors:  Joseph Daniel; Hena Ziaee; Chandra Pradhan; Derek J W McMinn
Journal:  Orthopedics       Date:  2008-12       Impact factor: 1.390

4.  Hip resurfacings revised for inflammatory pseudotumour have a poor outcome.

Authors:  G Grammatopoulos; G Grammatopolous; H Pandit; Y-M Kwon; R Gundle; P McLardy-Smith; D J Beard; D W Murray; H S Gill
Journal:  J Bone Joint Surg Br       Date:  2009-08

5.  Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings.

Authors:  Nicholas Bishop; Florian Witt; Robin Pourzal; Alfons Fischer; Marcel Rütschi; Markus Michel; Michael Morlock
Journal:  J Orthop Res       Date:  2013-02-25       Impact factor: 3.494

6.  Relationship of plasma metal ions and clinical and imaging findings in patients with ASR XL metal-on-metal total hip replacements.

Authors:  Eric Y Chang; James L McAnally; James R Van Horne; James G Van Horne; Tanya Wolfson; Anthony Gamst; Christine B Chung
Journal:  J Bone Joint Surg Am       Date:  2013-11-20       Impact factor: 5.284

7.  Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: the potential influence of the adapter sleeve.

Authors:  Martin Lavigne; Etienne L Belzile; Alain Roy; François Morin; Traian Amzica; Pascal-André Vendittoli
Journal:  J Bone Joint Surg Am       Date:  2011-05       Impact factor: 5.284

8.  Pseudotumours associated with metal-on-metal hip resurfacings.

Authors:  H Pandit; S Glyn-Jones; P McLardy-Smith; R Gundle; D Whitwell; C L M Gibbons; S Ostlere; N Athanasou; H S Gill; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2008-07

Review 9.  Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip.

Authors:  P-A Vendittoli; S Mottard; A G Roy; C Dupont; M Lavigne
Journal:  J Bone Joint Surg Br       Date:  2007-04

10.  Metal ion levels after metal-on-metal Ring total hip replacement: a 30-year follow-up study.

Authors:  P Sauvé; J Mountney; T Khan; J De Beer; B Higgins; M Grover
Journal:  J Bone Joint Surg Br       Date:  2007-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.