Literature DB >> 19298017

Systemic metal exposure in large- and small-diameter metal-on-metal total hip replacements.

Joseph Daniel1, Hena Ziaee, Chandra Pradhan, Derek J W McMinn.   

Abstract

Large-diameter metal-metal total hip replacement (THR) offers the advantages of low wear and low dislocation risk. the aim of this investigation was to compare metal levels in large and small-diameter metal-metal hip replacements. Whole blood concentrations and daily output of cobalt and chromium in 28 patients with unilateral large diameter (42- to 54-mm) metal on metal hip replacements at 1-year follow-up were compared with levels in patients with 28-mm metal-on-metal THRs. Both bearings were made of high-carbon cobalt-chrome alloy. The larger bearing is as-cast and the smaller wrought alloy. High-resolution inductively coupled plasma mass spectrometry was used for analysis. The patients had either a cemented polished tapered stainless steel stem or a cementless porous ingrowth titanium alloy stem. Mean whole blood levels in the small- and large-diameter THRs are not significantly different at 1 year (cobalt, 1.7 vs 2.3 microg/L and chromium 1.7 vs 1.4 microg/L). Daily urinary output of cobalt and chromium was also in the same range and without a significant mean difference (cobalt 11.6 microg/24 h in large-diameter and 12.3 microg/24 h in small-diameter THRs and chromium 3.7 and 4.1 microg/24 h, respectively).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19298017

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  6 in total

1.  Ultrasound findings in asymptomatic patients with modular metal on metal total hip arthroplasty.

Authors:  Nicholas B Frisch; Nolan M Wessell; Kevin Taliaferro; Marnix Van Holsbeeck; Craig D Silverton
Journal:  Skeletal Radiol       Date:  2017-02-15       Impact factor: 2.199

Review 2.  Metal-on-Metal Bearing: Is This the End of the Line? We Do Not Think So.

Authors:  Henri Migaud; Sophie Putman; Antoine Combes; Charles Berton; Donatien Bocquet; Laurent Vasseur; Julien Girard
Journal:  HSS J       Date:  2012-09-11

3.  Normalization of chromium and cobalt values after femoral head replacement.

Authors:  Claudio Iacobellis; Antonio Berizzi; Assunta Pozzuoli; Carlo Biz
Journal:  Int J Surg Case Rep       Date:  2015-03-27

Review 4.  Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties: a literature overview.

Authors:  Christopher Jantzen; Henrik L Jørgensen; Benn R Duus; Sune L Sporring; Jes B Lauritzen
Journal:  Acta Orthop       Date:  2013-04-18       Impact factor: 3.717

5.  Does bearing size influence metal ion levels in large-head metal-on-metal total hip arthroplasty? A comparison of three total hip systems.

Authors:  James Smith; David Lee; Kamal Bali; Pam Railton; David Kinniburgh; Peter Faris; Deborah Marshall; Brian Burkart; James Powell
Journal:  J Orthop Surg Res       Date:  2014-01-28       Impact factor: 2.359

6.  Ten-year results of a prospective cohort of large-head metal-on-metal total hip arthroplasty : a concise follow-up of a previous report.

Authors:  Christiaan P van Lingen; Harmen B Ettema; Bart H Bosker; Cees C P M Verheyen
Journal:  Bone Jt Open       Date:  2022-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.