Literature DB >> 26412000

Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting.

Mathew T Kattadiyil1, Rami Jekki2, Charles J Goodacre3, Nadim Z Baba4.   

Abstract

STATEMENT OF PROBLEM: Scientific evidence is lacking regarding the clinical effectiveness of digital complete removable dental prostheses (CRDP).
PURPOSE: This prospective clinical study was conducted to compare clinical treatment outcomes, patient satisfaction, and dental student preferences for digitally and conventionally processed CRDP in a predoctoral setting.
MATERIAL AND METHODS: This clinical study rated and compared CRDP fabricated by predoctoral students, using a 2-appointment digital prosthesis fabrication process as opposed to the conventional 5-appointment process. Fifteen completely edentulous patients were treated in the predoctoral clinic at Loma Linda University School of Dentistry. Fifteen predoctoral (third- and fourth-year) dental students fabricated 2 sets of maxillary and mandibular CRDP for each patient. Each patient received 1 conventional set and 1 digital (AvaDent) set of CRDP. Faculty and patient ratings, patient and student preferences, and perceptions of the conventional versus digital prostheses were recorded and analyzed. The average treatment time for the fabrication of each type of prostheses was analyzed.
RESULTS: Significantly higher average scores were observed for digital dentures than for conventional dentures according to criteria evaluated by faculty (P=.007). Patients reported significantly higher overall average satisfaction scores with digital dentures (P=.001). Patients preferred the digital dentures (P<.01). Significantly higher scores were observed for the retention of the digital maxillary complete denture (P=.001) compared with that for the digital mandibular and conventional complete dentures. Students preferred digital prostheses compared with conventional prostheses (P<.05). The conventional process required significantly more clinical time for each patient than with the digital process of fabrication (P<.01).
CONCLUSIONS: The digital process proved to be an equally effective and more time-efficient option than the conventional process of prosthesis fabrication in the predoctoral program. The digital denture process was preferred and effectively used by predoctoral dental students under faculty supervision.
Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26412000     DOI: 10.1016/j.prosdent.2015.08.001

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  22 in total

1.  Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial.

Authors:  Franz Sebastian Schwindling; Franziska Lehmann; Sophia Terebesi; Nicoleta Corcodel; Andreas Zenthöfer; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2017-02-11       Impact factor: 3.573

2.  CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness.

Authors:  Murali Srinivasan; Yoann Cantin; Albert Mehl; Harald Gjengedal; Frauke Müller; Martin Schimmel
Journal:  Clin Oral Investig       Date:  2016-11-08       Impact factor: 3.573

3.  CAD/CAM produces dentures with improved fit.

Authors:  Otto Steinmassl; Herbert Dumfahrt; Ingrid Grunert; Patricia-Anca Steinmassl
Journal:  Clin Oral Investig       Date:  2018-02-22       Impact factor: 3.573

4.  Comparison of shear bond strength of CAD/CAM and conventional heat-polymerized acrylic resin denture bases to auto-polymerized and heat-polymerized acrylic resins after aging.

Authors:  Masoumeh Taghva; Shabnam Enteghad; Ali Jamali; Mina Mohaghegh
Journal:  J Clin Exp Dent       Date:  2022-01-01

5.  Tissue Surface Adaptation and Clinical Performance of CAD-CAM Milled versus Conventional Implant-Assisted Mandibular Overdenture.

Authors:  Noha H El-Shaheed; Hanadi A Lamfon; Rabab I Salama; Amira Mohammed Gomaa Faramawy; Aisha Zakaria Hashem Mostafa
Journal:  Int J Dent       Date:  2022-06-16

Review 6.  Physical and Mechanical Properties of 3D-Printed Provisional Crowns and Fixed Dental Prosthesis Resins Compared to CAD/CAM Milled and Conventional Provisional Resins: A Systematic Review and Meta-Analysis.

Authors:  Saurabh Jain; Mohammed E Sayed; Mallika Shetty; Saeed M Alqahtani; Mohammed Hussain Dafer Al Wadei; Shilpi Gilra Gupta; Ahlam Abdulsalam Ahmed Othman; Abdulkarim Hussain Alshehri; Hatem Alqarni; Abdulaziz Hussain Mobarki; Khalid Motlaq; Haifa F Bakmani; Asma A Zain; Abdullah J Hakami; Moayad F Sheayria
Journal:  Polymers (Basel)       Date:  2022-06-30       Impact factor: 4.967

7.  The residual monomer content and mechanical properties of CAD\CAM resins used in the fabrication of complete dentures as compared to heat cured resins.

Authors:  Al-Dharrab Ayman
Journal:  Electron Physician       Date:  2017-07-25

8.  Total CAD/CAM Supported Method for Manufacturing Removable Complete Dentures.

Authors:  Arthur Furtado de Mendonça; Mario Furtado de Mendonça; George Shelby White; Georges Sara; Darren Littlefair
Journal:  Case Rep Dent       Date:  2016-11-16

9.  Integrating 3D facial scanning in a digital workflow to CAD/CAM design and fabricate complete dentures for immediate total mouth rehabilitation.

Authors:  Bassam Hassan; Marcus Greven; Daniel Wismeijer
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

Review 10.  Clinical Performance of CAD/CAM All-Ceramic Tooth-Supported Fixed Dental Prostheses: A Systematic Review and Meta-Analysis.

Authors:  Babak Saravi; Andreas Vollmer; Maja Hartmann; Gernot Lang; Ralf-Joachim Kohal; Martin Boeker; Sebastian B M Patzelt
Journal:  Materials (Basel)       Date:  2021-05-20       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.