Literature DB >> 28168338

Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study.

Ludovic Kaminski1, V Cordemans2, O Cartiaux2, M Van Cauter3.   

Abstract

PURPOSE: The goals of this paper are to assess the ionizing radiation exposure to the patients during thoracic and lumbar spinal fusion using a new intraoperative 3D imaging system and to evaluate the factors that could explain the variability in the observed doses.
METHOD: We retrospectively reviewed 97 patients who underwent posterior instrumented thoracic and/or lumbar spinal fusion from December 2013 to November 2014. Primary data were the total dose area product (total DAP, Gy cm2) and total skin dose (total SD, mGy). Influence of different variables (patient characteristics, surgical technique, and intraoperative imaging system parameters) that could influence patients' exposure was analyzed.
RESULTS: Radiation dose imparted to patients depended on four parameters including acquisition protocol, surgical technique, patient's BMI and operative time. Minimally invasive surgery (MIS) resulted in twofold higher dose for patients, compared to open surgery. The use of low dose acquisition protocols reduced patient exposure by a factor three.
CONCLUSION: Patient exposure was highly variable. Four parameters were found to explain about 68% of its variance when using a multi-axis robotic C-arm system. MIS technique (with navigation or not) as well as the acquisition protocol dramatically increases the radiation dose for patients. These results show the necessity to develop specific strategies adapted to patients and surgical procedures.

Entities:  

Keywords:  Cone-beam CT; Dose reduction strategies; Intraoperative imaging; Minimally invasive surgery; Mobile C-arm; Pedicle screws; Radiation exposure

Mesh:

Year:  2017        PMID: 28168338     DOI: 10.1007/s00586-017-4968-z

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  24 in total

1.  Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study.

Authors:  Sébastien Ruatti; C Dubois; E Chipon; G Kerschbaumer; M Milaire; A Moreau-Gaudry; J Tonetti; Ph Merloz
Journal:  Eur Spine J       Date:  2015-07-26       Impact factor: 3.134

2.  Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study.

Authors:  Roger Harstall; Paul F Heini; Roberto L Mini; Rene Orler
Journal:  Spine (Phila Pa 1976)       Date:  2005-08-15       Impact factor: 3.468

3.  Guidelines for patient radiation dose management.

Authors:  Michael S Stecker; Stephen Balter; Richard B Towbin; Donald L Miller; Eliseo Vañó; Gabriel Bartal; J Fritz Angle; Christine P Chao; Alan M Cohen; Robert G Dixon; Kathleen Gross; George G Hartnell; Beth Schueler; John D Statler; Thierry de Baère; John F Cardella
Journal:  J Vasc Interv Radiol       Date:  2009-07       Impact factor: 3.464

4.  Optimization of radiation exposure and image quality of the cone-beam O-arm intraoperative imaging system in spinal surgery.

Authors:  Kasim Abul-Kasim; Marcus Söderberg; Eufrozina Selariu; Mikael Gunnarsson; Mehrsa Kherad; Acke Ohlin
Journal:  J Spinal Disord Tech       Date:  2012-02

5.  Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance.

Authors:  S Schafer; S Nithiananthan; D J Mirota; A Uneri; J W Stayman; W Zbijewski; C Schmidgunst; G Kleinszig; A J Khanna; J H Siewerdsena
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

6.  Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels.

Authors:  M T Crawley; A T Rogers
Journal:  Br J Radiol       Date:  2000-07       Impact factor: 3.039

7.  Comparison between percutaneous and traditional fixation of lumbar spine fracture: intraoperative radiation exposure levels and outcomes.

Authors:  N Bronsard; T Boli; M Challali; R de Dompsure; N Amoretti; B Padovani; G Bruneton; A Fuchs; F de Peretti
Journal:  Orthop Traumatol Surg Res       Date:  2013-03-01       Impact factor: 2.256

8.  Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion.

Authors:  Kostas Perisinakis; Nicholas Theocharopoulos; John Damilakis; Pavlos Katonis; George Papadokostakis; Alexandros Hadjipavlou; Nicholas Gourtsoyiannis
Journal:  Spine (Phila Pa 1976)       Date:  2004-07-15       Impact factor: 3.468

9.  Intraoperative fluoroscopy, portable X-ray, and CT: patient and operating room personnel radiation exposure in spinal surgery.

Authors:  Elisha M Nelson; Shafagh M Monazzam; Kee D Kim; J Anthony Seibert; Eric O Klineberg
Journal:  Spine J       Date:  2014-06-07       Impact factor: 4.166

Review 10.  Methods for measuring fluoroscopic skin dose.

Authors:  Stephen Balter
Journal:  Pediatr Radiol       Date:  2006-09
View more
  9 in total

1.  Pedicle screw insertion accuracy in terms of breach and reposition using a new intraoperative cone beam computed tomography imaging technique and evaluation of the factors associated with these parameters of accuracy: a series of 695 screws.

Authors:  Virginie Cordemans; Ludovic Kaminski; Xavier Banse; Bernard G Francq; Christine Detrembleur; Olivier Cartiaux
Journal:  Eur Spine J       Date:  2017-06-19       Impact factor: 3.134

2.  Radiation dose reduction in thoracic and lumbar spine instrumentation using navigation based on an intraoperative cone beam CT imaging system: a prospective randomized clinical trial.

Authors:  Nathalie Pireau; Virginie Cordemans; Xavier Banse; Nadia Irda; Sébastien Lichtherte; Ludovic Kaminski
Journal:  Eur Spine J       Date:  2017-07-22       Impact factor: 3.134

3.  Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection.

Authors:  Virginie Cordemans; Ludovic Kaminski; Xavier Banse; Bernard G Francq; Olivier Cartiaux
Journal:  Eur Spine J       Date:  2017-05-20       Impact factor: 3.134

4.  Radiation exposure to the surgeon during minimally invasive spine procedures is directly estimated by patient dose.

Authors:  S Harrison Farber; Gautam Nayar; Rupen Desai; Elizabeth W Reiser; Sarah A Byrd; Deborah Chi; Cary Idler; Robert E Isaacs
Journal:  Eur Spine J       Date:  2018-06-08       Impact factor: 3.134

5.  Cone-Beam Navigation Can Reduce the Radiation Exposure and Save Fusion Length-Dependent Operation Time in Comparison to Conventional Fluoroscopy in Pedicle-Screw-Based Lumbar Interbody Fusion.

Authors:  Sebastian Rohe; Patrick Strube; Alexander Hölzl; Sabrina Böhle; Timo Zippelius; Chris Lindemann
Journal:  J Pers Med       Date:  2022-05-01

6.  The safety and accuracy of robot-assisted pedicle screw internal fixation for spine disease: a meta-analysis.

Authors:  Weishang Li; Gaoyu Li; Wenting Chen; Lin Cong
Journal:  Bone Joint Res       Date:  2020-10-10       Impact factor: 5.853

7.  Feasibility study of intraoperative cone-beam CT navigation for benign bone tumour surgery.

Authors:  Thomas R F van Steenbergen; Ingrid C M van der Geest; Dennis Janssen; Maroeska M Rovers; Jurgen J Fütterer
Journal:  Int J Med Robot       Date:  2019-03-20       Impact factor: 2.547

8.  Effective dose of radiation per screw in surgery of adolescent idiopathic scoliosis: matched pair analysis of 293 pedicle screws inserted using three different techniques.

Authors:  Markus Rafael Konieczny; Johannes Boos; Andrea Steuwe; Christoph Schleich; Max Prost; Rüdiger Krauspe
Journal:  J Child Orthop       Date:  2020-12-01       Impact factor: 1.548

Review 9.  Emerging Issues Questioning the Current Treatment Strategies for Lumbar Disc Herniation.

Authors:  Zhong Y Wan; Hua Shan; Tang F Liu; Fang Song; Jun Zhang; Zhi H Liu; Kun L Ma; Hai Q Wang
Journal:  Front Surg       Date:  2022-03-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.