Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study.

Roger Harstall1, Paul F Heini, Roberto L Mini, Rene Orler.   

Abstract

STUDY
DESIGN: A prospective case control study design was conducted.
OBJECTIVES: The purpose of the current study was to determine the intraoperative radiation hazard to spine surgeons by occupational radiation exposure during percutaneous vertebroplasty and possible consequences with respect to radiation protection. SUMMARY OF BACKGROUND DATA: The development of minimally invasive surgery techniques has led to an increasing number of fluoroscopically guided procedures being done percutaneously such as vertebroplasty, which is the percutaneous cement augmentation of vertebral bodies.
METHODS: Three months of occupational dose data for two spine surgeons was evaluated measuring the radiation doses to the thyroid gland, the upper extremities, and the eyes during vertebroplasty.
RESULTS: The annual risk of developing a fatal cancer of the thyroid is 0.0025%, which means a very small to small risk. The annual morbidity (the risk of developing a cancer including nonfatal ones) is 0.025%, which already means a small to medium risk. The dose for the eye lens was about 8% of the threshold dose to develop a radiation induced cataract (150 mSv); therefore, the risk is very low but not negligible. The doses measured for the skin are 10% of the annual effective dose limit (500 mSv) recommended by the ICRP (International Commission on Radiologic Protection); therefore, the annual risk for developing a fatal skin cancer is very low.
CONCLUSION: While performing percutaneous vertebroplasty, the surgeon is exposed to a significant amount of radiation. Proper surgical technique and shielding devices to decrease potentially high morbidity are mandatory. Training in radiation protection should be an integral part of the education for all surgeons using minimally invasive radiologic-guided interventional techniques.

Entities:  

Mesh:

Year:  2005        PMID: 16103862     DOI: 10.1097/01.brs.0000174121.48306.16

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  24 in total

1.  Comparative analysis of three different cervical lateral mass screw fixation techniques by complications and bicortical purchase : cadaveric study.

Authors:  Jin-Wook Baek; Dong-Mook Park; Dae-Hyun Kim
Journal:  J Korean Neurosurg Soc       Date:  2010-09-30

2.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures.

Authors:  E P Efstathopoulos; I Pantos; M Andreou; A Gkatzis; E Carinou; C Koukorava; N L Kelekis; E Brountzos
Journal:  Br J Radiol       Date:  2011-01       Impact factor: 3.039

Review 3.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

4.  A fast, accurate and closed-form method for pose recognition of an intramedullary nail using a tracked C-arm.

Authors:  H Esfandiari; S Amiri; D D Lichti; C Anglin
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-08       Impact factor: 2.924

5.  Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection.

Authors:  Virginie Cordemans; Ludovic Kaminski; Xavier Banse; Bernard G Francq; Olivier Cartiaux
Journal:  Eur Spine J       Date:  2017-05-20       Impact factor: 3.134

6.  Radiation exposure to the surgeon during minimally invasive spine procedures is directly estimated by patient dose.

Authors:  S Harrison Farber; Gautam Nayar; Rupen Desai; Elizabeth W Reiser; Sarah A Byrd; Deborah Chi; Cary Idler; Robert E Isaacs
Journal:  Eur Spine J       Date:  2018-06-08       Impact factor: 3.134

Review 7.  Occupational health related concerns among surgeons.

Authors:  Anjuman Gul Memon; Zahid Naeem; Atif Zaman; Faryal Zahid
Journal:  Int J Health Sci (Qassim)       Date:  2016-04

8.  Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty.

Authors:  Joshua R Smith; Rebecca M Marsh; Michael S Silosky
Journal:  Skeletal Radiol       Date:  2017-08-18       Impact factor: 2.199

9.  Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology.

Authors:  Donald L Miller; Eliseo Vañó; Gabriel Bartal; Stephen Balter; Robert Dixon; Renato Padovani; Beth Schueler; John F Cardella; Thierry de Baère
Journal:  Cardiovasc Intervent Radiol       Date:  2009-12-18       Impact factor: 2.740

10.  Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study.

Authors:  Ludovic Kaminski; V Cordemans; O Cartiaux; M Van Cauter
Journal:  Eur Spine J       Date:  2017-02-06       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.