Literature DB >> 23453915

Comparison between percutaneous and traditional fixation of lumbar spine fracture: intraoperative radiation exposure levels and outcomes.

N Bronsard1, T Boli, M Challali, R de Dompsure, N Amoretti, B Padovani, G Bruneton, A Fuchs, F de Peretti.   

Abstract

OBJECTIVE: To compare radiation exposure doses and clinical and radiological outcomes between percutaneous pedicular screwing (closed reduction internal fixation [CRIF]) and classical open reduction internal fixation (ORIF) in lumbar spine fracture without neurologic deficit.
MATERIALS AND METHODS: Sixty patients (mean age, 42.5 years) were divided into two treatment groups: (Percutaneous) CRIF versus (traditional) ORIF. Screw position and anatomic vertebral reconstruction were checked on routine control X-ray and postoperative CT scan. Study parameters comprised: surgery time, radiation exposure time, radiation dose level for X-ray (DAP) and for CT (DLP),blood loss, length of hospital stay and postoperative pain (VAS).
RESULTS: At a mean 25.5 months' follow-up,there were no significant inter-group differences on the epidemiological parameters: age, gender, fracture level, fracture type on the Magerl classification, preoperative local vertebral kyphosis angle, or fracture-to-surgery interval. Effective radiation dose was 3-fold higher in CRIF than in ORIF, but 6-fold lower than for the postoperative CT scan. Postoperative pain on VAS was significantly lower after CRIF, allowing earlier gait resumption and return to work and daily activity. There were no significant differences in length of hospital stay, patient satisfaction, screw malpositioning or postoperative or end-of-follow-up kyphosis angle.
CONCLUSION: Percutaneous surgery provided clinical and radiological outcomes strictly comparable to those of open surgery, but with a higher effective radiation exposure dose, including for the medical team and especially for the surgeon. This higher exposure dose, however, is to be relativized by comparison to that of the postoperative CT scan, which involved a much higher exposure dose for the patient. LEVEL OF EVIDENCE: Level IV. Retrospective study.
Copyright © 2013 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23453915     DOI: 10.1016/j.otsr.2012.12.012

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  17 in total

1.  Radiation exposure for the surgical team in a hybrid-operating room.

Authors:  Konard Schuetze; A Eickhoff; C Dehner; M Schultheiss; F Gebhard; P H Richter
Journal:  J Robot Surg       Date:  2018-05-10

2.  A new method to precisely control the depth of percutaneous screws into the pedicle by counting the rotation number of the screw with low radiation exposure: technical note.

Authors:  Xu Li; Feng Zhang; Wenzhi Zhang; Xifu Shang; Jintao Han; Pengfei Liu
Journal:  Eur Spine J       Date:  2016-11-14       Impact factor: 3.134

3.  Effect of the percutaneous pedicle screw fixation at the fractured vertebra on the treatment of thoracolumbar fractures.

Authors:  Kunpeng Li; Zhong Li; Xiaofeng Ren; Hui Xu; Wen Zhang; Dawei Luo; Jinzhu Ma
Journal:  Int Orthop       Date:  2016-03-17       Impact factor: 3.075

4.  Minimally invasive transforaminal lumbar interbody fusion with unilateral pedicle screw fixation (UNILIF): morbidity, clinical and radiological 2-year outcomes of a 66-patient prospective series.

Authors:  H Giorgi; R Prebet; R Andriantsimiavona; P Tropiano; B Blondel; H F Parent
Journal:  Eur Spine J       Date:  2018-01-10       Impact factor: 3.134

5.  Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study.

Authors:  Ludovic Kaminski; V Cordemans; O Cartiaux; M Van Cauter
Journal:  Eur Spine J       Date:  2017-02-06       Impact factor: 3.134

Review 6.  Augmented Reality (AR) in Orthopedics: Current Applications and Future Directions.

Authors:  Andrew A Furman; Wellington K Hsu
Journal:  Curr Rev Musculoskelet Med       Date:  2021-11-09

7.  Radiation Dose Reduction and Surgical Efficiency Improvement in Endoscopic Transforaminal Lumbar Interbody Fusion Assisted by Intraoperative O-arm Navigation: A Retrospective Observational Study.

Authors:  Junfeng Gong; Xinle Huang; Liwen Luo; Huan Liu; Hao Wu; Ying Tan; Changqing Li; Yu Tang; Yue Zhou
Journal:  Neurospine       Date:  2022-06-30

Review 8.  Does less invasive spine surgery result in increased radiation exposure? A systematic review.

Authors:  Elizabeth Yu; Safdar N Khan
Journal:  Clin Orthop Relat Res       Date:  2014-06       Impact factor: 4.176

9.  Percutaneous versus open pedicle screw fixation for treatment of type A thoracolumbar fractures.

Authors:  Jan Kocis; Martin Kelbl; Tomas Kocis; Tomas Návrat
Journal:  Eur J Trauma Emerg Surg       Date:  2018-08-23       Impact factor: 3.693

Review 10.  Minimally invasive spine surgeries for treatment of thoracolumbar fractures of spine: A systematic review.

Authors:  Chaitanya Dev Pannu; Kamran Farooque; Vijay Sharma; Deepika Singal
Journal:  J Clin Orthop Trauma       Date:  2019-04-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.