B Balachandran1, G Melich2, T Mustafa1, S J Marecik1, L M Prasad1, M Gonzalez3, S Sulo4, F Dabbous4, J J Park5. 1. Division of Colon and Rectal Surgery, Advocate Lutheran General Hospital, 1775 Dempster Street, Park Ridge, IL, 60068, USA. 2. Department of Surgery, Royal Columbian Hospital, University of British Columbia, New Westminster, BC, Canada. 3. Division of Pathology, Advocate Lutheran General Hospital, Park Ridge, IL, USA. 4. James R. & Helen D. Russell Institute for Research & Innovation, Advocate Lutheran General Hospital, Park Ridge, IL, USA. 5. Division of Colon and Rectal Surgery, Advocate Lutheran General Hospital, 1775 Dempster Street, Park Ridge, IL, 60068, USA. jpark18@aol.com.
Abstract
BACKGROUND: The sealing and transection of mesenteric vessels is a crucial step in minimally invasive colorectal surgery. We examined the sealing quality of the ENSEAL® G2 Articulating Tissue Sealer in three different articulations in mesenteric vessels. METHODS: This was a prospective experimental study within a tertiary healthcare center, and 30 patients were recruited. Burst pressures for each specimen were measured as the primary outcome. Ten specimens at each of the three articulations were also histologically assessed for the quality of seal. RESULTS: We evaluated 54 sets of specimens from 30 patients for bursting pressure, all of which were harvested and sealed in the operating room. No statistical difference was seen in burst pressures from seals recorded at no angulation, half-maximal angulation, or maximal angulation (1604, 1507, 1478 mmHg; p = 0.07). Histological analysis showed no statistical differences in the average vessel diameter (p = 0.57), lateral extent of thermal injury (p = 0.48), degree of vascular sclerosis, or the integrity of seal at the three articulations. No cases of intraoperative or postoperative bleeding were observed in any of the patients. Five (16.7%) of the ENSEAL® devices developed breaks in the black, heat-shrink, polyethylene covering as a result of repeated articulation and disarticulation. Electrical arcing did not appear to have occurred as a result of the break, although this was not formally examined. CONCLUSIONS: The maximum sustainable pressure in mesenteric vessels sealed with a bipolar electrothermal device is supraphysiological, and consequently, the device can be safely used at various articulations to seal vessels during colorectal surgery.
BACKGROUND: The sealing and transection of mesenteric vessels is a crucial step in minimally invasive colorectal surgery. We examined the sealing quality of the ENSEAL® G2 Articulating Tissue Sealer in three different articulations in mesenteric vessels. METHODS: This was a prospective experimental study within a tertiary healthcare center, and 30 patients were recruited. Burst pressures for each specimen were measured as the primary outcome. Ten specimens at each of the three articulations were also histologically assessed for the quality of seal. RESULTS: We evaluated 54 sets of specimens from 30 patients for bursting pressure, all of which were harvested and sealed in the operating room. No statistical difference was seen in burst pressures from seals recorded at no angulation, half-maximal angulation, or maximal angulation (1604, 1507, 1478 mmHg; p = 0.07). Histological analysis showed no statistical differences in the average vessel diameter (p = 0.57), lateral extent of thermal injury (p = 0.48), degree of vascular sclerosis, or the integrity of seal at the three articulations. No cases of intraoperative or postoperative bleeding were observed in any of the patients. Five (16.7%) of the ENSEAL® devices developed breaks in the black, heat-shrink, polyethylene covering as a result of repeated articulation and disarticulation. Electrical arcing did not appear to have occurred as a result of the break, although this was not formally examined. CONCLUSIONS: The maximum sustainable pressure in mesenteric vessels sealed with a bipolar electrothermal device is supraphysiological, and consequently, the device can be safely used at various articulations to seal vessels during colorectal surgery.
Authors: Jaime Landman; Kurt Kerbl; Jamil Rehman; Cassio Andreoni; Peter A Humphrey; William Collyer; Ephrem Olweny; Chandru Sundaram; Ralph V Clayman Journal: J Urol Date: 2003-02 Impact factor: 7.450
Authors: Marcus Overhaus; Nico Schaefer; Klaus Walgenbach; Andreas Hirner; Mara Natascha Szyrach; René Hany Tolba Journal: Minim Invasive Ther Allied Technol Date: 2012-01-31 Impact factor: 2.442
Authors: Ralf Rothmund; Bernhard Kraemer; Felix Neis; Sara Brucker; Markus Wallwiener; Ali Reda; Andrea Hausch; Marcus Scharpf; Mara Natascha Szyrach Journal: Surg Endosc Date: 2012-06-08 Impact factor: 4.584
Authors: Benjamin Person; David A Vivas; Dan Ruiz; Michael Talcott; James E Coad; Steven D Wexner Journal: Surg Endosc Date: 2007-12-20 Impact factor: 4.584
Authors: Geoffrey N Box; Hak J Lee; Jose B Abraham; Leslie A Deane; Erick R Elchico; Corollos A Abdelshehid; Reza Alipanah; Michael B Taylor; Lorena Andrade; Robert A Edwards; James F Borin; Elspeth M McDougall; Ralph V Clayman Journal: J Urol Date: 2008-11-17 Impact factor: 7.450
Authors: William L Newcomb; William W Hope; Thomas M Schmelzer; Jessica J Heath; H James Norton; Amy E Lincourt; B Todd Heniford; David A Iannitti Journal: Surg Endosc Date: 2008-05-16 Impact factor: 4.584
Authors: Gregory R Lamberton; Ryan S Hsi; Daniel H Jin; Tekisha U Lindler; Forrest C Jellison; D Duane Baldwin Journal: J Endourol Date: 2008-10 Impact factor: 2.942
Authors: Christian W Wallwiener; Taufiek K Rajab; Wolfgang Zubke; Keith B Isaacson; Markus Enderle; Daniel Schäller; Markus Wallwiener Journal: J Minim Invasive Gynecol Date: 2008-07-21 Impact factor: 4.137
Authors: Anthony Gonzalez; Christian Hernandez Murcia; Rey Romero; Ernesto Escobar; Pedro Garcia; Gail Walker; Michelle Gallas; Eugene Dickens; Bruce McIntosh; William Norwood; Keith Kim; Jorge Rabaza; Don Parris Journal: Surg Endosc Date: 2015-11-05 Impact factor: 4.584
Authors: Pasquale De Franciscis; Marco La Verde; Luigi Cobellis; Antonio Mollo; Marco Torella; Fulvio De Simone; Gaetano Maria Munno; Emanuele Amabile; Carla Loreto; Angela Celardo; Nicola Fortunato; Gaetano Riemma Journal: Medicina (Kaunas) Date: 2022-04-23 Impact factor: 2.948