Literature DB >> 19010491

Comparative study of in vivo lymphatic sealing capability of the porcine thoracic duct using laparoscopic dissection devices.

Geoffrey N Box1, Hak J Lee, Jose B Abraham, Leslie A Deane, Erick R Elchico, Corollos A Abdelshehid, Reza Alipanah, Michael B Taylor, Lorena Andrade, Robert A Edwards, James F Borin, Elspeth M McDougall, Ralph V Clayman.   

Abstract

PURPOSE: Sealing the lymphatic vessels during abdominal and pelvic surgery is important to prevent the leakage of lymphatic fluid and its resultant sequelae. To our knowledge we compared for the first time the quality of lymphatic sealing by each of 4 commonly used laparoscopic dissection devices.
MATERIALS AND METHODS: A total of 12 domestic pigs were used to test dissecting devices, including monopolar scissors (Ethicon Endo-Surgery, Cincinnati, Ohio), Harmonic ACE Scalpel, LigaSure V, EnSeal and Trissector. A midline incision was made from mid sternum to umbilicus, the diaphragm was divided and the porcine thoracic duct was isolated. In all animals each device was used to seal an area of the duct and each seal was placed at least 2 cm from the prior seal. In group 1 the thoracic duct of 6 pigs was cannulated with a 5Fr catheter and the seal was subjected to burst pressure testing using a burst pressure measuring device (Cole-Parmer, Vernon Hills, Illinois). In the 6 pigs in group 2 each seal was immediately sent for histopathological evaluation. Specimens were given a score for the extent of cautery damage, including 0-none, 1-minimal, 2-moderate, 3-severe and 4-extreme.
RESULTS: A total of 64 seals were created, of which 35 were subjected to burst pressure testing. Mean size of the thoracic duct was 2.6 mm. No acute seal failures were observed with any bipolar device or the harmonic shears. However, 2 immediate failures (33%) were seen with monopolar scissors. Mean burst pressure for monopolar scissors, Harmonic ACE Scalpel, LigaSure V, EnSeal and Trissector was 46 (range 0 to 165), 540 (range 175 to 795), 258 (range 75 to 435), 453 (range 255 to 825) and 379 mm Hg (range 175 to 605), respectively (p <0.05). Trissector, Harmonic ACE Scalpel and EnSeal generated seals with significantly higher burst pressure than that of monopolar scissors (p <0.05). Histopathological evaluation revealed that LigaSure caused less thermal damage than Trissector and EnSeal (p <0.05).
CONCLUSIONS: Each device tested except monopolar scissors consistently produced a supraphysiological seal and should be suitable for sealing lymphatic vessels during laparoscopic surgery.

Entities:  

Mesh:

Year:  2008        PMID: 19010491     DOI: 10.1016/j.juro.2008.08.122

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  8 in total

1.  Efficacy and safety of the novel electrosurgical vessel sealing and cutting instrument BiCision®.

Authors:  Ralf Rothmund; Bernhard Kraemer; Felix Neis; Sara Brucker; Markus Wallwiener; Ali Reda; Andrea Hausch; Marcus Scharpf; Mara Natascha Szyrach
Journal:  Surg Endosc       Date:  2012-06-08       Impact factor: 4.584

2.  Prospective analysis of the sealing ability of the ENSEAL® G2 Articulating Tissue Sealer and transector on human mesenteric vessels in colorectal surgery.

Authors:  B Balachandran; G Melich; T Mustafa; S J Marecik; L M Prasad; M Gonzalez; S Sulo; F Dabbous; J J Park
Journal:  Tech Coloproctol       Date:  2017-01-31       Impact factor: 3.781

Review 3.  How to minimize lymphoceles and treat clinically symptomatic lymphoceles after radical prostatectomy.

Authors:  Hak J Lee; Christopher J Kane
Journal:  Curr Urol Rep       Date:  2014-10       Impact factor: 3.092

4.  Microbiological evaluation of infected pelvic lymphocele after robotic prostatectomy: potential predictors for culture positivity and selection of the best empirical antimicrobial therapy.

Authors:  Alaa Hamada; Catalina Hwang; Jorge Fleisher; Ingolf Tuerk
Journal:  Int Urol Nephrol       Date:  2017-04-24       Impact factor: 2.370

Review 5.  Common uses and cited complications of energy in surgery.

Authors:  Ganesh Sankaranarayanan; Rajeswara R Resapu; Daniel B Jones; Steven Schwaitzberg; Suvranu De
Journal:  Surg Endosc       Date:  2013-04-23       Impact factor: 4.584

6.  Comparison of the value of tissue-sealing devices for thoracoscopic pulmonary lobectomy in small children: a first report.

Authors:  Hiroyuki Koga; Kenji Suzuki; Kinya Nishimura; Manabu Okawada; Takashi Doi; Geoffrey J Lane; Eiichi Inada; Tadaharu Okazaki; Atsuyuki Yamataka
Journal:  Pediatr Surg Int       Date:  2014-07-30       Impact factor: 1.827

Review 7.  Non-vascular experimental and clinical applications of advanced bipolar radiofrequency thermofusion technology in the thorax and abdomen: a systematic review.

Authors:  Shobhit Arya; Hugh Mackenzie; George B Hanna
Journal:  Surg Endosc       Date:  2014-11-19       Impact factor: 4.584

8.  Modern lymphatic dissection techniques for preventing post renal transplant lymphocele.

Authors:  Ciprian Valerian Lucan; Ionut Jurchis; Mihai Suciu; Sonia Emilia Selicean; Salvatore Buttice
Journal:  Clujul Med       Date:  2017-10-20
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.