Literature DB >> 22292919

Efficiency and safety of bipolar vessel and tissue sealing in visceral surgery.

Marcus Overhaus1, Nico Schaefer, Klaus Walgenbach, Andreas Hirner, Mara Natascha Szyrach, René Hany Tolba.   

Abstract

BACKGROUND: The aim of this study was to analyze the efficiency and safety of the bipolar tissue/vessel sealing and cutting device EnSeal(™) in comparison to the conventional clamp and ligation technique in visceral surgery.
MATERIAL AND METHODS: In an acute animal model, a part of the small bowel, a part of the colon and the kidneys were resected either with the conventional clamp and ligation technique or with EnSeal(™). Operation time, blood loss and blood parameters as well as the lateral thermal spread were evaluated.
RESULTS: Small bowel, colon and kidney resection time with the EnSeal(™) device was shorter compared to the conventional clamp and ligation technique (small bowel: EnSeal(™): 4.7 ± 1.0 min vs. con: 35.1 ± 2.3 min; colon: EnSeal(™): 7.0 ± 1.4 min vs. con: 16.3 ± 1.5 min, kidney: EnSeal(™): 5.7 ± 1.3 min vs. con: 16.7 ± 3.7 min, p < 0.05) and blood loss was significantly lower. Blood analysis demonstrated no differences in both groups. The lateral thermal spread was not more than 1 mm with EnSeal(™).
CONCLUSION: The bipolar sealing in visceral surgery with EnSeal(™) can be performed more efficiently in a shorter time, with significantly less blood loss, minimal thermal damage and without changes of blood parameters, indicating biological safety and integrity.

Entities:  

Mesh:

Year:  2012        PMID: 22292919     DOI: 10.3109/13645706.2011.651145

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  6 in total

1.  Prospective analysis of the sealing ability of the ENSEAL® G2 Articulating Tissue Sealer and transector on human mesenteric vessels in colorectal surgery.

Authors:  B Balachandran; G Melich; T Mustafa; S J Marecik; L M Prasad; M Gonzalez; S Sulo; F Dabbous; J J Park
Journal:  Tech Coloproctol       Date:  2017-01-31       Impact factor: 3.781

2.  Perpendicular blood vessel seals are stronger than those made at an angle.

Authors:  Aaron C Voegele; Donna L Korvick; Mario Gutierrez; Jeffrey W Clymer; Joseph F Amaral
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2013-06-11       Impact factor: 1.878

3.  Cervical Detachment Using Monopolar SupraLoop™ Electrode versus Monopolar Needle in Laparoscopic Supracervical Hysterectomy (LSH): An Interventional, Comparative Cohort Study.

Authors:  S Brucker; R Rothmund; B Krämer; F Neis; B Schönfisch; W Zubke; F A Taran; M Wallwiener
Journal:  Geburtshilfe Frauenheilkd       Date:  2013-11       Impact factor: 2.915

4.  Detection of the Lateral Thermal Spread during Bipolar Vessel Sealing in an Ex Vivo Model-Preliminary Results.

Authors:  Andreas Kirschbaum; Jan Jonas; Thomas M Surowiec; Anika Pehl; Nikolas Mirow
Journal:  Diagnostics (Basel)       Date:  2022-05-12

5.  Consistency and sealing of advanced bipolar tissue sealers.

Authors:  Edward G Chekan; Mark A Davison; David W Singleton; John Z Mennone; Piet Hinoul
Journal:  Med Devices (Auckl)       Date:  2015-04-20

6.  Safety and effectiveness of a novel generator algorithm for bipolar vessel sealing: a randomised controlled chronic animal study.

Authors:  Bernhard Kraemer; Christos Tsaousidis; Stephan Kruck; Martin Schenk; Marcus Scharpf; Stefan Kommoss; Sara Brucker; Daniela Nuessle; Markus D Enderle; Ulrich Biber
Journal:  BMC Surg       Date:  2019-11-05       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.