Literature DB >> 28116512

Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children.

Hyun Gi Kim1, Ho-Joon Lee2, Seung-Koo Lee2, Hyun Ji Kim3, Myung-Joon Kim4.   

Abstract

OBJECTIVE: To investigate the quality of images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V), using pediatric head CT protocols.
METHODS: A phantom was scanned at decreasing 20% mA intervals using our standard pediatric head CT protocols. Each study was then reconstructed at 10% ASIR-V intervals. After the phantom study, we reduced mA by 10% in the protocol for <3-year-old patients and applied 30% ASIR-V and by 30% in the protocol for 3- to 15-year-old patients and applied 40% ASIR-V.
RESULTS: Increasing the percentage of ASIR-V resulted in lower noise and higher contrast-to-noise ratio (CNR) and preserved spatial resolution in the phantom study. Compared to a conventional-protocol, reduced-dose protocol with ASIR-V achieved 12.8% to 34.0% of dose reduction and showed images of lower noise (9.22 vs. 10.73, P = 0.043) and higher CNR in different levels (centrum semiovale, 2.14 vs. 1.52, P = 0.003; basal ganglia, 1.46 vs. 1.07, P = 0.001; and cerebellum, 2.18 vs. 1.33, P < 0.001). Qualitative analysis showed higher gray-white matter differentiation and sharpness and preserved overall diagnostic quality in the images with ASIR-V.
CONCLUSIONS: Use of ASIR-V allowed a 12.8% to 34.0% dose reduction in each age group with potential to improve image quality. KEY POINTS: • It is possible to reduce radiation dose and improve image quality with ASIR-V. • We improved noise and CNR and decreased radiation dose. • Sharpness improved with ASIR-V. • Total radiation dose was decreased by 12.8% to 34.0%.

Entities:  

Keywords:  Brain; Computer-assisted methods; Pediatric; Radiation dosage; Radiation protection methods

Mesh:

Year:  2017        PMID: 28116512     DOI: 10.1007/s00330-017-4733-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  22 in total

Review 1.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

2.  The Image Gently campaign: working together to change practice.

Authors:  Marilyn J Goske; Kimberly E Applegate; Jennifer Boylan; Priscilla F Butler; Michael J Callahan; Brian D Coley; Shawn Farley; Donald P Frush; Marta Hernanz-Schulman; Diego Jaramillo; Neil D Johnson; Sue C Kaste; Greg Morrison; Keith J Strauss; Nora Tuggle
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

3.  Radiation dose reduction in soft tissue neck CT using adaptive statistical iterative reconstruction (ASIR).

Authors:  Behroze Vachha; Harald Brodoefel; Carol Wilcox; David B Hackney; Gul Moonis
Journal:  Eur J Radiol       Date:  2013-08-23       Impact factor: 3.528

4.  Medical radiation exposure in the U.S. in 2006: preliminary results.

Authors:  Fred A Mettler; Bruce R Thomadsen; Mythreyi Bhargavan; Debbie B Gilley; Joel E Gray; Jill A Lipoti; John McCrohan; Terry T Yoshizumi; Mahadevappa Mahesh
Journal:  Health Phys       Date:  2008-11       Impact factor: 1.316

5.  Lowering the dose in head CT using adaptive statistical iterative reconstruction.

Authors:  K Kilic; G Erbas; M Guryildirim; M Arac; E Ilgit; B Coskun
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-11       Impact factor: 3.825

Review 6.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

7.  Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v.

Authors:  Kyungjae Lim; Heejin Kwon; Jinhan Cho; Jongyoung Oh; Seongkuk Yoon; Myungjin Kang; Dongho Ha; Jinhwa Lee; Eunju Kang
Journal:  J Comput Assist Tomogr       Date:  2015 May-Jun       Impact factor: 1.826

8.  Patient radiation doses from adult and pediatric CT.

Authors:  Walter Huda; Awais Vance
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

9.  Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination.

Authors:  Colin D McKnight; Kuanwong Watcharotone; Mohannad Ibrahim; Emmanuel Christodoulou; Aaron H Baer; Hemant A Parmar
Journal:  Pediatr Radiol       Date:  2014-04-03

10.  A Survey of Pediatric CT Protocols and Radiation Doses in South Korean Hospitals to Optimize the Radiation Dose for Pediatric CT Scanning.

Authors:  Jae-Yeon Hwang; Kyung-Hyun Do; Dong Hyun Yang; Young Ah Cho; Hye-Kyung Yoon; Jin Seong Lee; Hyun Jung Koo
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

View more
  13 in total

1.  Potential value of the PixelShine deep learning algorithm for increasing quality of 70 kVp+ASiR-V reconstruction pelvic arterial phase CT images.

Authors:  Shi-Feng Tian; Ai-Lian Liu; Jing-Hong Liu; Yi-Jun Liu; Ju-Dong Pan
Journal:  Jpn J Radiol       Date:  2018-12-06       Impact factor: 2.374

2.  Comparison of Iterative Model Reconstruction versus Filtered Back-Projection in Pediatric Emergency Head CT: Dose, Image Quality, and Image-Reconstruction Times.

Authors:  R N Southard; D M E Bardo; M H Temkit; M A Thorkelson; R A Augustyn; C A Martinot
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-11       Impact factor: 3.825

3.  Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 1: computed tomography.

Authors:  David Célier; Patrice Roch; Cécile Etard; Hubert Ducou Le Pointe; Hervé J Brisse
Journal:  Eur Radiol       Date:  2019-09-05       Impact factor: 5.315

4.  Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy.

Authors:  Woong Kyu Han; Joon Chae Na; Sung Yoon Park
Journal:  Eur Radiol       Date:  2019-08-30       Impact factor: 5.315

5.  Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose.

Authors:  Hyun-Hae Cho; So Mi Lee; Sun Kyoung You
Journal:  Pediatr Radiol       Date:  2019-10-19

6.  Deep learning image reconstruction in pediatric abdominal and chest computed tomography: a comparison of image quality and radiation dose.

Authors:  Kun Zhang; Xiang Shi; Shuang-Shuang Xie; Ji-Hang Sun; Zhuo-Heng Liu; Shuai Zhang; Jia-Yang Song; Wen Shen
Journal:  Quant Imaging Med Surg       Date:  2022-06

7.  Impact of preset and postset adaptive statistical iterative reconstruction-V on image quality in nonenhanced abdominal-pelvic CT on wide-detector revolution CT.

Authors:  Zheng Zhu; Yanfeng Zhao; Xinming Zhao; Xiaoyi Wang; Weijun Yu; Mancang Hu; Xuan Zhang; Chunwu Zhou
Journal:  Quant Imaging Med Surg       Date:  2021-01

8.  Quantitative and qualitative evaluation of hybrid iterative reconstruction, with and without noise power spectrum models: A phantom study.

Authors:  Kazuya Minamishima; Koichi Sugisawa; Yoshitake Yamada; Masahiro Jinzaki
Journal:  J Appl Clin Med Phys       Date:  2018-02-28       Impact factor: 2.102

9.  Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp.

Authors:  Chankue Park; Ki Seok Choo; Jin Hyeok Kim; Kyung Jin Nam; Ji Won Lee; Jin You Kim
Journal:  Korean J Radiol       Date:  2019-07       Impact factor: 3.500

10.  Application of a deep learning image reconstruction (DLIR) algorithm in head CT imaging for children to improve image quality and lesion detection.

Authors:  Jihang Sun; Haoyan Li; Bei Wang; Jianying Li; Michelle Li; Zuofu Zhou; Yun Peng
Journal:  BMC Med Imaging       Date:  2021-07-08       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.