Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination.

Colin D McKnight1, Kuanwong Watcharotone, Mohannad Ibrahim, Emmanuel Christodoulou, Aaron H Baer, Hemant A Parmar.   

Abstract

BACKGROUND: Over the last decade there has been escalating concern regarding the increasing radiation exposure stemming from CT exams, particularly in children. Adaptive statistical iterative reconstruction (ASIR) is a relatively new and promising tool to reduce radiation dose while preserving image quality. While encouraging results have been found in adult head and chest and body imaging, validation of this technique in pediatric population is limited.
OBJECTIVE: The objective of our study was to retrospectively compare the image quality and radiation dose of pediatric head CT examinations obtained with ASIR compared to pediatric head CT examinations without ASIR in a large patient population.
MATERIALS AND METHODS: Retrospective analysis was performed on 82 pediatric head CT examinations. This group included 33 pediatric head CT examinations obtained with ASIR and 49 pediatric head CT examinations without ASIR. Computed tomography dose index (CTDIvol) was recorded on all examinations. Quantitative analysis consisted of standardized measurement of attenuation and the standard deviation at the bilateral centrum semiovale and cerebellar white matter to evaluate objective noise. Qualitative analysis consisted of independent assessment by two radiologists in a blinded manner of gray-white differentiation, sharpness and overall diagnostic quality.
RESULTS: The average CTDIvol value of the ASIR group was 21.8 mGy (SD = 4.0) while the average CTDIvol for the non-ASIR group was 29.7 mGy (SD = 13.8), reflecting a statistically significant reduction in CTDIvol in the ASIR group (P < 0.01). There were statistically significant reductions in CTDI for the 3- to 12-year-old ASIR group as compared to the 3- to 12-year-old non-ASIR group (21.5 mGy vs. 30.0 mGy; P = 0.004) as well as statistically significant reductions in CTDI for the >12-year-old ASIR group as compared to the >12-year-old non-ASIR group (29.7 mGy vs. 49.9 mGy; P = 0.0002). Quantitative analysis revealed no significant difference in the homogeneity of variance in the ASIR group compared to the non-ASIR group. Radiologist assessment of gray-white differentiation, sharpness and overall diagnostic quality in ASIR examinations was not substantially different compared to non-ASIR examinations.
CONCLUSION: The use of ASIR in pediatric head CT examinations allows for a 28% CTDIvol reduction in the 3- to 12-year-old age group and a 48% reduction in the >12-year-old age group without substantially affecting image quality.

Entities:  

Mesh:

Year:  2014        PMID: 24696285     DOI: 10.1007/s00247-014-2943-y

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  13 in total

1.  Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.

Authors:  Yoshiko Sagara; Amy K Hara; William Pavlicek; Alvin C Silva; Robert G Paden; Qing Wu
Journal:  AJR Am J Roentgenol       Date:  2010-09       Impact factor: 3.959

Review 2.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

3.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

4.  Lowering the dose in head CT using adaptive statistical iterative reconstruction.

Authors:  K Kilic; G Erbas; M Guryildirim; M Arac; E Ilgit; B Coskun
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-11       Impact factor: 3.825

Review 5.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

6.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

7.  Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study.

Authors:  Gregory A Vorona; Rafael C Ceschin; Barbara L Clayton; Tom Sutcavage; Sameh S Tadros; Ashok Panigrahy
Journal:  Pediatr Radiol       Date:  2011-05-19

Review 8.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

9.  Studies of the mortality of atomic bomb survivors, Report 14, 1950-2003: an overview of cancer and noncancer diseases.

Authors:  Kotaro Ozasa; Yukiko Shimizu; Akihiko Suyama; Fumiyoshi Kasagi; Midori Soda; Eric J Grant; Ritsu Sakata; Hiromi Sugiyama; Kazunori Kodama
Journal:  Radiat Res       Date:  2011-12-15       Impact factor: 2.841

10.  An approach for the estimation of effective radiation dose at CT in pediatric patients.

Authors:  W Huda; J V Atherton; D E Ware; W A Cumming
Journal:  Radiology       Date:  1997-05       Impact factor: 11.105

View more
  13 in total

1.  Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.

Authors:  Oliver Rompel; Martin Glöckler; Rolf Janka; Sven Dittrich; Robert Cesnjevar; Michael M Lell; Michael Uder; Matthias Hammon
Journal:  Pediatr Radiol       Date:  2016-01-06

2.  Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography.

Authors:  Lin Yang; Jian Zhuang; Meiping Huang; Changhong Liang; Hui Liu
Journal:  Pediatr Radiol       Date:  2016-09-16

3.  Full Dose-Reduction Potential of Statistical Iterative Reconstruction for Head CT Protocols in a Predominantly Pediatric Population.

Authors:  A E Mirro; S L Brady; R A Kaufman
Journal:  AJNR Am J Neuroradiol       Date:  2016-04-07       Impact factor: 3.825

4.  Radiation dose reduction in CT-guided spine biopsies does not reduce diagnostic yield.

Authors:  K A Shpilberg; B N Delman; L N Tanenbaum; S J Esses; R Subramaniam; A H Doshi
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-17       Impact factor: 3.825

5.  Comparison of Iterative Model Reconstruction versus Filtered Back-Projection in Pediatric Emergency Head CT: Dose, Image Quality, and Image-Reconstruction Times.

Authors:  R N Southard; D M E Bardo; M H Temkit; M A Thorkelson; R A Augustyn; C A Martinot
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-11       Impact factor: 3.825

6.  Effect of the forward-projected model-based iterative reconstruction solution algorithm on image quality and radiation dose in pediatric cardiac computed tomography.

Authors:  Yukako Nishiyama; Keiji Tada; Yuichi Nishiyama; Hiroshi Mori; Mitsunari Maruyama; Takashi Katsube; Nobuko Yamamoto; Hidekazu Kanayama; Yasushi Yamamoto; Hajime Kitagaki
Journal:  Pediatr Radiol       Date:  2016-08-16

7.  Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose.

Authors:  Hyun-Hae Cho; So Mi Lee; Sun Kyoung You
Journal:  Pediatr Radiol       Date:  2019-10-19

8.  Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children.

Authors:  Hyun Gi Kim; Ho-Joon Lee; Seung-Koo Lee; Hyun Ji Kim; Myung-Joon Kim
Journal:  Eur Radiol       Date:  2017-01-23       Impact factor: 5.315

9.  Radiation dose reduction using 100-kVp and a sinogram-affirmed iterative reconstruction algorithm in adolescent head CT: Impact on grey-white matter contrast and image noise.

Authors:  Yasunori Nagayama; Takeshi Nakaura; Akinori Tsuji; Joji Urata; Mitsuhiro Furusawa; Hideaki Yuki; Kenichiro Hirarta; Masafumi Kidoh; Seitaro Oda; Daisuke Utsunomiya; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2016-12-13       Impact factor: 5.315

10.  Benchmarking pediatric cranial CT protocols using a dose tracking software system: a multicenter study.

Authors:  Timo De Bondt; Tom Mulkens; Federica Zanca; Lotte Pyfferoen; Jan W Casselman; Paul M Parizel
Journal:  Eur Radiol       Date:  2016-06-03       Impact factor: 5.315

View more