| Literature DB >> 28107817 |
Taku Oshima1, Séverine Graf2, Claudia-Paula Heidegger3, Laurence Genton2, Jérôme Pugin3, Claude Pichard2.
Abstract
BACKGROUND: Methods to calculate energy expenditure (EE) based on CO2 measurements (EEVCO2) have been proposed as a surrogate to indirect calorimetry. This study aimed at evaluating whether EEVCO2 could be considered as an alternative to EE measured by indirect calorimetry.Entities:
Keywords: Accuracy; Critical care; Energy expenditure; Indirect calorimetry
Mesh:
Substances:
Year: 2017 PMID: 28107817 PMCID: PMC5251283 DOI: 10.1186/s13054-016-1595-8
Source DB: PubMed Journal: Crit Care ISSN: 1364-8535 Impact factor: 9.097
Patient characteristics
| Patients |
| 278 | (100.0) |
| Male | 191 | (68.7) | |
| Female | 87 | (31.3) | |
| Age, years | 56 | (18) | |
| Height, cm | 172 | (9) | |
| Anamnestic body weight, kg | 76 | (18) | |
| Body mass index, kg/m2 | 25.9 | (5.9) | |
| Admission diagnosis |
| ||
| Shock | 60 | (21.6) | |
| Multiple trauma | 52 | (18.7) | |
| Neurologic | 31 | (11.2) | |
| Respiratory failure | 22 | (7.9) | |
| Cardiac surgery | 20 | (7.2) | |
| Pneumonia | 18 | (6.5) | |
| Acute pancreatitis | 11 | (4.0) | |
| Myocardial infarction | 10 | (3.6) | |
| Post-cardiac arrest | 8 | (2.9) | |
| Liver failure | 8 | (2.9) | |
| Others | 38 | (13.7) | |
| APACHE II score | 24 | (7) | |
| SAPS II | 51 | (17) | |
| Length of ICU stay, days | median (IQR) | 21 | (12–37) |
| ICU day of evaluation, days | median (IQR) | 8 | (4–18) |
| Glasgow Coma Scale | median (IQR) | 10 | (8–14) |
| Sedation-Agitation Scale | median (IQR) | 4 | (3–4) |
| Body temperature, °C | 37.3 | (0.6) | |
| FiO2, % | 30 | (7) | |
| Minute volume, L/min BTPS | 12 | (3) | |
| VO2, mL/min STPD | 279 | (61) | |
| VCO2, mL/min STPD | 234 | (53) | |
| Respiratory quotient | 0.84 | (0.09) | |
| Energy expenditure, kcal/day | 1956 | (426) | |
| Energy provision, kcal/day | 1658 | (696) | |
| Energy provision rate, % | 86 | (35) | |
| Nutrition route |
| ||
| Enteral nutrition (EN) | 196 | (70.5) | |
| Parenteral nutrition (PN) | 24 | (8.6) | |
| EN + PN | 55 | (19.8) | |
| Non-nutrition energy sources | 3 | (1.1) | |
| Food quotient | 0.87 | (0.01) |
Results shown as mean (standard deviation) unless otherwise indicated
APACHE Acute Physiology and Chronic Health Evaluation, SAPS Simplified Acute Physiology Score, FiO fraction of inspired O2, BTPS body temperature (37 °C) ambient pressure water saturated condition, STPD standard temperature (0 °C) standard pressure (760 mmHg) dry condition, VO volume of O2 consumption, VCO volume of CO2 production, IQR interquartile range
Comparison of energy expenditure based on CO2 measurements (EEVCO2) to energy expenditure (EE) measured by indirect calorimetry in mean bias and accuracy rates
| Mean, SD | Mean bias | 95% CI | SD of bias |
| Accuracy rates (%) | ||
|---|---|---|---|---|---|---|---|
| (kcal/d) | (kcal/d) | Lower, upper | 5% | 10% | |||
| EEVCO2_0.85 | 1936, 441 | -21 | -41, 1 | 171 | 0.042 | 46.0 | 77.7 |
| EEVCO2_FQ | 1908, 439 | -48 | -67, -28 | 163 | 0.000 | 46.4 | 77.3 |
Mean bias mean difference between EEVCO2 and measured EE, p values: paired Student t tests, accuracy rates proportion of EEVCO2 values within 5% or 10% of the measured EE
SD standard deviation, CI confidence intervals, EEVCO _0.85 EE calculated using measured CO2 consumption (VCO2) and fixed respiratory quotient (RQ) of 0.85, EEVCO _FQ EE calculated using VCO2 and the food quotient as the RQ
Fig 1Correlation and limits of agreement between calculated energy expenditure based on CO2 measurements (EEVCO2) and energy expenditure (EE) measured by indirect calorimetry. a EEVCO2_0.85 vs. measured EE. b EEVCO2_FQ vs. measured EE. Solid lines indicate the bias and fine dotted lines indicate the limits of agreement in the Bland-Altman plots. EEVCO 2 _0.85 EEVCO2 calculated from CO2 consumption (VCO2) and assumed respiratory quotient (RQ) of 0.85, EEVCO 2 _FQ EEVCO2 calculated from VCO2 and assuming RQ as food quotient (FQ)
Accuracy of energy expenditure based on CO2 measurements (EEVCO2) versus energy expenditure (EE) measured by indirect calorimetry according to the timing of evaluation and energy provision rate at the time of evaluation
|
| EEVCO2_0.85 | EEVCO2_FQ | ||||||
|---|---|---|---|---|---|---|---|---|
| ±5% EE | (%) |
| ±5% EE | (%) |
| |||
| Timing of evaluation | ≤7 ICU day | 131 | 58 | 44 | 0.577 | 59 | 45 | 0.667 |
| >7 ICU day | 147 | 70 | 48 | 70 | 48 | |||
| Energy provision | <90% EE | 139 | 65 | 47 | 0.810 | 63 | 45 | 0.718 |
| ≥90% EE | 139 | 63 | 45 | 66 | 47 | |||
Timing of evaluation: patient stratification by measurements before or after the 7th day after ICU admission, Energy provision: patient stratification according to the proportion of energy provision at the time of measurement < 90 or ≥ 90% of EE, ±5%.
EEVCO 2 _0.85 EE calculated using measured CO2 consumption (VCO2) and fixed respiratory quotient (RQ) of 0.85, EEVCO 2 _FQ EE calculated using measured VCO2 and the food quotient (FQ) as the RQ, EE number of patients with EEVCO2 values within ±5% of EE, P values: chi-square tests