Literature DB >> 28093625

Ultralow dose CT for pulmonary nodule detection with chest x-ray equivalent dose - a prospective intra-individual comparative study.

Michael Messerli1,2, Thomas Kluckert3, Meinhard Knitel3, Stephan Wälti3,4, Lotus Desbiolles3, Fabian Rengier5, René Warschkow6, Ralf W Bauer3, Hatem Alkadhi7, Sebastian Leschka3,7, Simon Wildermuth3.   

Abstract

PURPOSE: To prospectively evaluate the accuracy of ultralow radiation dose CT of the chest with tin filtration at 100 kV for pulmonary nodule detection.
MATERIALS AND METHODS: 202 consecutive patients undergoing clinically indicated chest CT (standard dose, 1.8 ± 0.7 mSv) were prospectively included and additionally scanned with an ultralow dose protocol (0.13 ± 0.01 mSv). Standard dose CT was read in consensus by two board-certified radiologists to determine the presence of lung nodules and served as standard of reference (SOR). Two radiologists assessed the presence of lung nodules and their locations on ultralow dose CT. Sensitivity and specificity of the ultralow dose protocol was compared against the SOR, including subgroup analyses of different nodule sizes and types. A mixed effects logistic regression was used to test for independent predictors for sensitivity of pulmonary nodule detection.
RESULTS: 425 nodules (mean diameter 3.7 ± 2.9 mm) were found on SOR. Overall sensitivity for nodule detection by ultralow dose CT was 91%. In multivariate analysis, nodule type, size and patients BMI were independent predictors for sensitivity (p < 0.001).
CONCLUSIONS: Ultralow dose chest CT at 100 kV with spectral shaping enables a high sensitivity for the detection of pulmonary nodules at exposure levels comparable to plain film chest X-ray. KEYPOINTS: • 91% of all lung nodules were detected with ultralow dose CT • Sensitivity for subsolid nodule detection is lower in ultralow dose CT (77.5%) • The mean effective radiation dose in 202 patients was 0.13 mSv • Ultralow dose CT seems to be feasible for lung cancer screening.

Entities:  

Keywords:  Computed Tomography; Image reconstruction; Lung cancer; Pulmonary Nodule; Radiation Dosage

Mesh:

Year:  2017        PMID: 28093625     DOI: 10.1007/s00330-017-4739-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  32 in total

1.  Low-dose CT of the lung: potential value of iterative reconstructions.

Authors:  Stephan Baumueller; Anna Winklehner; Christoph Karlo; Robert Goetti; Thomas Flohr; Erich W Russi; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2012-06-15       Impact factor: 5.315

2.  Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Jeanne B Ackman; Subba R Digumarthy; Jiang Hsieh; Synho Do; Jo-Anne O Shepard; Matthew D Gilman
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

3.  Performance of ultralow-dose CT with iterative reconstruction in lung cancer screening: limiting radiation exposure to the equivalent of conventional chest X-ray imaging.

Authors:  Adrian Huber; Julia Landau; Lukas Ebner; Yanik Bütikofer; Lars Leidolt; Barbara Brela; Michelle May; Johannes Heverhagen; Andreas Christe
Journal:  Eur Radiol       Date:  2016-01-26       Impact factor: 5.315

4.  Fleischner Society: glossary of terms for thoracic imaging.

Authors:  David M Hansell; Alexander A Bankier; Heber MacMahon; Theresa C McLoud; Nestor L Müller; Jacques Remy
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

5.  Survival of patients with true pathologic stage I non-small cell lung cancer.

Authors:  Robert J Cerfolio; Ayesha S Bryant
Journal:  Ann Thorac Surg       Date:  2009-09       Impact factor: 4.330

6.  A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction.

Authors:  Jonathon Leipsic; Giang Nguyen; Jaqueline Brown; Don Sin; John R Mayo
Journal:  AJR Am J Roentgenol       Date:  2010-11       Impact factor: 3.959

7.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

8.  Trends in incidence and prognosis of the histological subtypes of lung cancer in North America, Australia, New Zealand and Europe.

Authors:  M L Janssen-Heijnen; J W Coebergh
Journal:  Lung Cancer       Date:  2001 Feb-Mar       Impact factor: 5.705

9.  Cancer incidence and mortality worldwide: sources, methods and major patterns in GLOBOCAN 2012.

Authors:  Jacques Ferlay; Isabelle Soerjomataram; Rajesh Dikshit; Sultan Eser; Colin Mathers; Marise Rebelo; Donald Maxwell Parkin; David Forman; Freddie Bray
Journal:  Int J Cancer       Date:  2014-10-09       Impact factor: 7.396

10.  NELSON lung cancer screening study.

Authors:  Ying Ru Zhao; Xueqian Xie; Harry J de Koning; Willem P Mali; Rozemarijn Vliegenthart; Matthijs Oudkerk
Journal:  Cancer Imaging       Date:  2011-10-03       Impact factor: 3.909

View more
  23 in total

1.  Radiation burden and associated cancer risk for a typical population to be screened for lung cancer with low-dose CT: A phantom study.

Authors:  Kostas Perisinakis; Ioannis Seimenis; Antonis Tzedakis; Apostolos Karantanas; John Damilakis
Journal:  Eur Radiol       Date:  2018-04-12       Impact factor: 5.315

2.  Whole-body ultra-low dose CT using spectral shaping for detection of osteolytic lesion in multiple myeloma.

Authors:  Saravanabavaan Suntharalingam; Christian Mikat; Axel Wetter; Nika Guberina; Ahmed Salem; Philipp Heil; Michael Forsting; Kai Nassenstein
Journal:  Eur Radiol       Date:  2018-01-10       Impact factor: 5.315

3.  Chest CT screening in patients with overweight or obesity using spectral shaping at 150 kVp: compared with 120 kVp protocol and spectral shaping at 100 kVp protocol.

Authors:  Jianwen Li; Zhifeng Mai; Zhihong Zhang; Jiamang Cui; Mingjie Yang; Xia Ma; Yan Wang
Journal:  Jpn J Radiol       Date:  2020-02-11       Impact factor: 2.374

4.  Diagnostic accuracy of chest X-ray dose-equivalent CT for assessing calcified atherosclerotic burden of the thoracic aorta.

Authors:  Michael Messerli; Andreas A Giannopoulos; Sebastian Leschka; René Warschkow; Simon Wildermuth; Lukas Hechelhammer; Ralf W Bauer
Journal:  Br J Radiol       Date:  2017-10-03       Impact factor: 3.039

5.  A pilot study on lung cancer detection based on regional metabolic activity distribution in digital low-dose 18F-FDG PET.

Authors:  Michael Messerli; Urs J Muehlematter; Saskia Fassbind; Daniel Franzen; Daniela A Ferraro; Martin W Huellner; Valerie Treyer; Alessandra Curioni-Fontecedro; Irene A Burger
Journal:  Br J Radiol       Date:  2021-02-02       Impact factor: 3.039

6.  Low-dose CT with tin filter combined with iterative metal artefact reduction for guiding lung biopsy.

Authors:  Jing Zhang; Meiling Liu; Daihong Liu; Xiaoqin Li; Meng Lin; Yong Tan; Yuesheng Luo; Xiangfei Zeng; Hong Yu; Hesong Shen; Xiaoxia Wang; Leilei Liu; Yuchuan Tan; Jiuquan Zhang
Journal:  Quant Imaging Med Surg       Date:  2022-02

7.  Effect of adaptive statistical iterative reconstruction-V (ASiR-V) levels on ultra-low-dose CT radiomics quantification in pulmonary nodules.

Authors:  Kai Ye; Min Chen; Qiao Zhu; Yuliu Lu; Huishu Yuan
Journal:  Quant Imaging Med Surg       Date:  2021-06

8.  Dual-source computed tomography of the lung with spectral shaping and advanced iterative reconstruction: potential for maximum radiation dose reduction.

Authors:  Matthias Wetzl; Matthias S May; Daniel Weinmann; Matthias Hammon; Christoph Treutlein; Martin Zeilinger; Alexander Kiefer; Regina Trollmann; Joachim Woelfle; Michael Uder; Oliver Rompel
Journal:  Pediatr Radiol       Date:  2020-06-17

9.  Ultralow dose computed tomography protocol for hook-wire localization of solitary pulmonary nodules prior to video-assisted thoracoscopic surgery.

Authors:  Bo Liu; Jie Fang; Haipeng Jia; Zhigang Sun; Jian Liao; Hong Meng; Fengmin Pan; Chunhai Li
Journal:  Thorac Cancer       Date:  2019-05-01       Impact factor: 3.500

10.  Comparing the diagnostic performance of radiation dose-equivalent radiography, multi-detector computed tomography and cone beam computed tomography for finger fractures - A phantom study.

Authors:  Carolin Sophie Reidelbach; Sebastian Moritz Goerke; Simon Carl Leschka; Claudia Neubauer; Martin Soschynski; Florian Lampert; Horst Zajonc; Elmar Kotter; Mathias Langer; Jakob Neubauer
Journal:  PLoS One       Date:  2019-03-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.