| Literature DB >> 31044556 |
Bo Liu1, Jie Fang2, Haipeng Jia1, Zhigang Sun3, Jian Liao4, Hong Meng1, Fengmin Pan1, Chunhai Li1.
Abstract
BACKGROUND: This study prospectively investigated the efficacy and radiation dose of ultralow dose computed tomography (CT)-guided hook-wire localization (HWL) at 100 kV with tin filtration (100Sn kV) for small solitary pulmonary nodules.Entities:
Keywords: Ultralow dose; VATS; hook-wire; localization; pulmonary nodule
Mesh:
Year: 2019 PMID: 31044556 PMCID: PMC6558453 DOI: 10.1111/1759-7714.13075
Source DB: PubMed Journal: Thorac Cancer ISSN: 1759-7706 Impact factor: 3.500
Patient and nodule characteristics
| Characteristics | Group A ( | Group B ( |
|
|---|---|---|---|
| Male/Female | 19/25 | 20/24 | 0.83 |
| Age (years) | 58.8 ± 8.8 | 57.3 ± 9.8 | 0.43 |
| Smoking history | 21 (47.7%) | 24 (54.5%) | 0.52 |
| Mild‐moderate emphysema | 15 (34.1%) | 13 (29.5%) | 0.65 |
| BMI (kg/m2) | 26.1 ± 1.31 | 25.7 ± 1.8 | 0.24 |
| Nodule size (cm) | 1.34 ± 0.52 | 1.45 ± 0.40 | 0.29 |
| < 1 | 9 (20.5%) | 5 (11.4%) | |
| 1–2 | 28 (63.6%) | 33 (75.0%) | |
| > 2 | 7 (15.9%) | 6 (13.6%) | |
| Nodule location | 0.82 | ||
| Upper and middle | 29 (65.9%) | 30 (68.2%) | |
| Lower | 15 (34.1%) | 14 (31.8%) | |
| Nodule feature | 0.62 | ||
| GGN | 34 (77.3%) | 32 (72.7%) | |
| SN | 10 (23.7%) | 12 (27.3%) | |
| Position | 0.73 | ||
| Supine | 24 (54.5%) | 21 (47.7%) | |
| Prone | 16 (36.4%) | 17 (38.6%) | |
| Decubitus | 4 (9.1%) | 6 (13.7%) | |
| Nodule distance to pleural surface (mm) | 11.6 ± 6.9 | 9.84 ± 7.4 | 0.28 |
| Nodule distance to hook‐wire (mm) | 0.52 | ||
| Intra‐nodular | 21 (47.7%) | 18 (40.9%) | |
| 2–10 mm | 23 (52.3%) | 26 (59.1%) | |
| HWL duration (minutes) | 19.6 ± 4.3 | 21.4 ± 5.8 | 0.11 |
| VATS duration (minutes) | 49.5 ± 13.4 | 47.6 ± 9.1 | 0.45 |
| HWL complications | |||
| Minor pneumothorax | 11 (25.0%) | 13 (29.5%) | 0.63 |
| Hemorrhage | 10 (22.7%) | 9 (20.5%) | 0.79 |
| Dislodgement | 0 | 0 |
BMI, body mass index; GGN, ground‐glass nodule; HWL, hook‐wire localization; SN, solid nodule; VATS, video‐assisted thoracoscopic surgery.
Figure 1Computed tomography‐guided hook‐wire localization by two protocols. (a) Standard dose protocol: axial image shows successful hook‐wire placement into a pulmonary nodule in the right lower lobe of a 48‐year woman. Asymptomatic minor pneumothorax was observed. (b) Ultralow dose protocol: axial image shows successful hook‐wire placement into a pulmonary nodule in the right upper lobe of a 58‐year woman.
Histopathologic results
| Variables | Group A ( | Group B ( |
|---|---|---|
| Malignancy | 36 (81.8%) | 39 (88.6%) |
| Adenocarcinoma | 28 | 31 |
| AIS | 2 | 3 |
| MIA | 8 | 5 |
| IA | 18 | 23 |
| Squamous cell carcinoma | 3 | 2 |
| Small cell lung carcinoma | 2 | 1 |
| Metastasis | 3 | 5 |
| Benign | 8 (18.2%) | 5 (11.4%) |
| Focal inflammation | 5 | 3 |
| Fibrosis | 1 | 1 |
| Tuberculosis | 2 | 1 |
AIS, adenocarcinoma in situ; IA, invasive adenocarcinoma; MIA, minimally invasive adenocarcinoma.
Radiation dose parameters and subjective image quality
| Parameters | Group A | Group B |
|
|---|---|---|---|
| Total scan length (cm) | 36.9 ± 2.6 | 37.7 ± 3.0 | 0.26 |
| CTDIvol (mGy) | 3.2 ± 1.1 | 0.32 | < 0.001 |
| Total DLP (mGy‐cm) | 120 ± 40.6 | 12.1 ± 0.97 | < 0.001 |
| ED (mSv) | 1.68 ± 0.57 | 0.17 ± 0.01 | < 0.001 |
| Subjective image quality | 4.31 ± 0.7 | 3.68 ± 0.6 | < 0.001 |
CTDIvol, volume CT dose index; DLP, dose‐length product; ED, effective dose.