Literature DB >> 17618922

CAD/CAM-guided implant surgery and fabrication of an immediately loaded prosthesis for a partially edentulous patient.

Christopher B Marchack1.   

Abstract

The treatment planning, placement, and restoration of dental implants for the partially edentulous patient can be challenging. Anatomical limitations can make implant location difficult to determine. The use of CT scans and surgical planning software to produce a CAD/CAM surgical template, as well as the use of a flapless surgical technique, can make implant placement more predictable, safer, and easier for patients. The article describes a computer-guided surgical technique for the partially edentulous patient, with a restoration fabricated prior to implant placement, for immediate loading.

Entities:  

Mesh:

Year:  2007        PMID: 17618922     DOI: 10.1016/S0022-3913(07)60028-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Full digital workflow for implant-prosthetic rehabilitations: a case report.

Authors:  L Arcuri; C Lorenzi; F Cecchetti; F Germano; M Spuntarelli; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2016-07-23

2.  Direct metal laser sintering (DMLS) of a customized titanium mesh for prosthetically guided bone regeneration of atrophic maxillary arches.

Authors:  L Ciocca; M Fantini; F De Crescenzio; G Corinaldesi; R Scotti
Journal:  Med Biol Eng Comput       Date:  2011-07-21       Impact factor: 2.602

3.  Survey of UK dentists regarding the use of CAD/CAM technology.

Authors:  D Tran; M Nesbit; H Petridis
Journal:  Br Dent J       Date:  2016-11-18       Impact factor: 1.626

4.  Computer-assisted virtual treatment planning combined with flapless surgery and immediate loading in the rehabilitation of partial edentulies.

Authors:  G DE Vico; D Spinelli; M Bonino; R Schiavetti; A Pozzi; L Ottria
Journal:  Oral Implantol (Rome)       Date:  2012-07-17

5.  What is the effect of initial implant position on the crestal bone level in flap and flapless technique during healing period?

Authors:  Mohammed Jasim Al-Juboori; Shaifulizan Ab Rahman; Akram Hassan; Ikmal Hisham Bin Ismail; Omar Farouq Tawfiq
Journal:  J Periodontal Implant Sci       Date:  2013-08-31       Impact factor: 2.614

6.  Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study.

Authors:  Du-Hyeong Lee; Seo-Young An; Min-Ho Hong; Kyoung-Bae Jeon; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2016-06-17       Impact factor: 1.904

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.