A prospective evaluation of contrast and radiation dose and image quality in cardiac CT in children with complex congenital heart disease using low-concentration iodinated contrast agent and low tube voltage and current.

Qiao-Ru Hou1, Wei Gao2, Ai-Min Sun1, Qian Wang1, Hai-Sheng Qiu1, Fang Wang3, Li-Wei Hu1, Jian-Ying Li4, Yu-Min Zhong1.   

Abstract

OBJECTIVE: To the assess image quality, contrast dose and radiation dose in cardiac CT in children with congenital heart disease (CHD) using low-concentration iodinated contrast agent and low tube voltage and current in comparison with standard dose protocol.
METHODS: 110 patients with CHD were randomized to 1 of the 2 scan protocols: Group A (n = 45) with 120 mA tube current and contrast agent of 270 mgI/ml in concentration (Visipaque™; GE Healthcare Ireland, Co., Cork, UK); and Group B (n = 65) with the conventional 160 mA and 370 mgI/ml concentration contrast (Iopamiro®; Shanghai Bracco Sine Pharmaceutical Corp Ltd, Shanghai, China). Both groups used 80 kVp tube voltage and were reconstructed with 70% adaptive statistical iterative reconstruction algorithm. The CT value and noise in aortic arch were measured and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-point scale was used to subjectively evaluate image quality. Contrast and radiation dose were recorded.
RESULTS: There was no difference in age and weight between the two groups (all p > 0.05). The iodine load and radiation dose in Group A were statistically lower (3976 ± 747 mgI vs 5763 ± 1018 mgI in iodine load and 0.60 ± 0.08 mSv vs 0.77 ± 0.10 mSv in effective dose; p < 0.001). However, image noise, CT value, CNR, SNR and subjective image quality for the two groups were similar (all p > 0.05), and with good agreement between the two observers. Comparing the surgery results, the diagnostic accuracy for extracardiac and intracardiac defects for Group A was 96% and 92%, respectively, while the corresponding numbers for Group B were 95% and 93%.
CONCLUSION: Compared with the standard dose protocol, the use of low tube voltage (80 kVp), low tube current (120 mA) and low-concentration iodinated contrast agent (270 mgI/ml) enables a reduction of 30% in iodine load and 22% in radiation dose while maintaining compatible image quality and diagnostic accuracy. Advances in knowledge: The new cardiac CT scanning protocol can largely reduce the adverse effects of radiation and contrast media to children. Meanwhile, it also can be used effectively to examine complex CHD.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27925466      PMCID: PMC5685110          DOI: 10.1259/bjr.20160669

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  23 in total

1.  Coronary CT angiography using low concentrated contrast media injected with high flow rates: Feasible in clinical practice.

Authors:  Casper Mihl; Madeleine Kok; Joachim E Wildberger; Sibel Altintas; David Labus; Estelle C Nijssen; Babs M F Hendriks; Bas L J H Kietselaer; Marco Das
Journal:  Eur J Radiol       Date:  2015-07-26       Impact factor: 3.528

2.  Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography.

Authors:  Jiang Hsieh; John Londt; Melissa Vass; Jay Li; Xiangyang Tang; Darin Okerlund
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

3.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

4.  Cancer risks from diagnostic radiology: the impact of new epidemiological data.

Authors:  E J Hall; D J Brenner
Journal:  Br J Radiol       Date:  2012-12       Impact factor: 3.039

5.  16-MDCT angiography in living kidney donors at various tube potentials: impact on image quality and radiation dose.

Authors:  Dushyant V Sahani; Sanjeeva P Kalva; Peter F Hahn; Sanjay Saini
Journal:  AJR Am J Roentgenol       Date:  2007-01       Impact factor: 3.959

6.  Limitation of transthoracic echocardiography in the diagnosis of congenital heart diseases.

Authors:  J Soongswang; A Nana; D Laohaprasitiporn; K Durongpisitkul; C Kangkagate; W Rochanasiri; T Kovitcharoentrakul
Journal:  J Med Assoc Thai       Date:  2000-11

7.  Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease.

Authors:  Wei Gao; Yu Min Zhong; Ai Min Sun; Qian Wang; Rong Zhen Ouyang; Li Wei Hu; Han Sheng Qiu; Shi Yu Wang; Jian Ying Li
Journal:  Int J Cardiovasc Imaging       Date:  2016-02-20       Impact factor: 2.357

8.  Successful Dose Reduction Using Reduced Tube Voltage With Hybrid Iterative Reconstruction in Pediatric Abdominal CT.

Authors:  Sheila C Berlin; Dayna M Weinert; Pauravi S Vasavada; Claudia Martinez-Rios; Roshni A Parikh; Michael A Wien; David W Jordan; Ronald D Novak
Journal:  AJR Am J Roentgenol       Date:  2015-08       Impact factor: 3.959

9.  Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters.

Authors:  Hatem Alkadhi; Paul Stolzmann; Hans Scheffel; Lotus Desbiolles; Stephan Baumüller; André Plass; Michele Genoni; Borut Marincek; Sebastian Leschka
Journal:  Eur J Radiol       Date:  2008-10-30       Impact factor: 3.528

10.  Optimizing contrast media injection protocols in state-of-the art computed tomographic angiography.

Authors:  Michael M Lell; Gregor Jost; Johannes Georg Korporaal; Andreas Horst Mahnken; Thomas G Flohr; Michael Uder; Hubertus Pietsch
Journal:  Invest Radiol       Date:  2015-03       Impact factor: 6.016

View more
  4 in total

Review 1.  Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments.

Authors:  Sandeep S Hedgire; Vinit Baliyan; Brian B Ghoshhajra; Mannudeep K Kalra
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-24

2.  Clinical Question Influence on Radiation Dose of Cardiac CT Scan in Children.

Authors:  Theodor Adla; Martin Kočí; Vojtěch Suchánek; Zuzana Šalagovičová; Michal Polovinčák; Lukáš Mikšík; Jan Janoušek; Miloslav Roček
Journal:  Children (Basel)       Date:  2022-08-05

3.  Catheter, MRI and CT Imaging in Newborns with Pulmonary Atresia with Ventricular Septal Defect and Aortopulmonary Collaterals: Quantifying the Risks of Radiation Dose and Anaesthetic Time.

Authors:  David F A Lloyd; Sebastian Goreczny; Conal Austin; Tarique Hussain; Shakeel A Qureshi; Eric Rosenthal; Thomas Krasemann
Journal:  Pediatr Cardiol       Date:  2018-05-09       Impact factor: 1.655

4.  Chest CTA in children younger than two years - a retrospective comparison of three contrast injection protocols.

Authors:  Eszter Nagy; Sebastian Tschauner; Robert Marterer; Regina Riedl; Erich Sorantin
Journal:  Sci Rep       Date:  2019-12-02       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.