Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease.

Wei Gao1, Yu Min Zhong2, Ai Min Sun3, Qian Wang3, Rong Zhen Ouyang3, Li Wei Hu3, Han Sheng Qiu3, Shi Yu Wang3, Jian Ying Li4.   

Abstract

To explore the clinical value and evaluate the diagnostic accuracy of sub-mSv low-dose prospective ECG-triggering cardiac CT (CCT) in young infants with complex congenital heart disease (CHD). A total of 102 consecutive infant patients (53 boys and 49 girls with mean age of 2.9 ± 2.4 m and weight less than 5 kg) with complex CHD were prospectively enrolled. Scans were performed on a 64-slice high definition CT scanner with low dose prospective ECG-triggering mode and reconstructed with 80 % adaptive statistical iterative reconstruction algorithm. All studies were performed during free breathing with sedation. The subjective image quality was evaluated by 5-point grading scale and interobserver variability was calculated. The objective image noise (standard deviation, SD) and contrast to noise ratio (CNR) was calculated. The effective radiation dose from the prospective ECG-triggering mode was recorded and compared with the virtual conventional retrospective ECG-gating mode. The detection rate for the origin of coronary artery was calculated. All patients also underwent echocardiography before CCT examination. 81 patients had surgery and their preoperative CCT and echocardiography findings were compared with the surgical results and sensitivity, specificity, positive and negative predictive values and accuracy were calculated for separate cardiovascular anomalies. Heart rates were 70-161 beats per minute (bpm) with mean value of 129.19 ± 14.52 bpm. The effective dose of 0.53 ± 0.15 mSv in the prospective ECG-triggering cardiac CT was lower than the calculated value in a conventional retrospective ECG-gating mode (2.00 ± 0.35 mSv) (p < 0.001). The mean CNR and SD were 28.19 ± 13.00 and 15.75 ± 3.61HU, respectively. The image quality scores were 4.31 ± 0.36 and 4.29 ± 0.41 from reviewer 1 and 2 respectively with an excellent agreement between them (Kappa = 0.85). The detection rate for the origins of the left and right coronary arteries was 96 and 90 %, respectively. The detection rates of the origins of left coronary artery and right coronary artery in all cases were 96 % (78/81) and 90 % (73/81), respectively. Twenty cases of conotruncal anomalies and ALCAPA were validated surgically and the accuracy of cardiac CT diagnosis was 95 % (19/20). The overall deformity based sensitivity, specificity, positive predictive value and negative predictive value were 94.0.1, 99.9, 98.6, 99.5 % respectively, by CCT, and 88.2, 99.9, 97.8, 99.0 %, respectively, by echocardiography. Prospective ECG-triggering CCT with sub-mSv effective dose provides excellent imaging quality and high diagnostic accuracy for young infants with complex CHD.

Entities:  

Keywords:  Cardiac CT angiography; Congenital heart disease; Prospective ECG-triggering; Radiation exposure

Mesh:

Year:  2016        PMID: 26897005     DOI: 10.1007/s10554-016-0854-8

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  19 in total

Review 1.  Paediatric cardiac computed tomography: a review of imaging techniques and radiation dose consideration.

Authors:  Carolyn Young; Andrew M Taylor; Catherine M Owens
Journal:  Eur Radiol       Date:  2010-12-28       Impact factor: 5.315

2.  Multimodality noninvasive imaging for assessment of congenital heart disease.

Authors:  Ashwin Prakash; Andrew J Powell; Tal Geva
Journal:  Circ Cardiovasc Imaging       Date:  2010-01       Impact factor: 7.792

Review 3.  Radiation dose modulation techniques in the multidetector CT era: from basics to practice.

Authors:  Chang Hyun Lee; Jin Mo Goo; Hyun Ju Ye; Sung-Joon Ye; Chang Min Park; Eun Ju Chun; Jung-Gi Im
Journal:  Radiographics       Date:  2008 Sep-Oct       Impact factor: 5.333

Review 4.  Cardiac MDCT in children: CT technology overview and interpretation.

Authors:  Hyun Woo Goo
Journal:  Radiol Clin North Am       Date:  2011-09       Impact factor: 2.303

5.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

6.  Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation.

Authors:  Hyun Woo Goo; Hyum Woo Goo; Dong Soo Suh
Journal:  Pediatr Radiol       Date:  2006-02-25

7.  Limitation of transthoracic echocardiography in the diagnosis of congenital heart diseases.

Authors:  J Soongswang; A Nana; D Laohaprasitiporn; K Durongpisitkul; C Kangkagate; W Rochanasiri; T Kovitcharoentrakul
Journal:  J Med Assoc Thai       Date:  2000-11

8.  Prospective electrocardiography-triggered CT angiography of the great thoracic vessels in infants and toddlers with congenital heart disease: feasibility and image quality.

Authors:  Gregor Pache; Jochen Grohmann; Stefan Bulla; Raoul Arnold; Brigitte Stiller; Christian Schlensak; Mathias Langer; Philipp Blanke
Journal:  Eur J Radiol       Date:  2011-02-09       Impact factor: 3.528

9.  Lessons we have learned from our children: cancer risks from diagnostic radiology.

Authors:  Eric J Hall
Journal:  Pediatr Radiol       Date:  2002-07-19

10.  Cancer risks attributable to low doses of ionizing radiation: assessing what we really know.

Authors:  David J Brenner; Richard Doll; Dudley T Goodhead; Eric J Hall; Charles E Land; John B Little; Jay H Lubin; Dale L Preston; R Julian Preston; Jerome S Puskin; Elaine Ron; Rainer K Sachs; Jonathan M Samet; Richard B Setlow; Marco Zaider
Journal:  Proc Natl Acad Sci U S A       Date:  2003-11-10       Impact factor: 11.205

View more
  7 in total

1.  Evaluation of complex congenital heart disease in infants using low dose cardiac computed tomography.

Authors:  Jannika Dodge-Khatami; Dilachew A Adebo
Journal:  Int J Cardiovasc Imaging       Date:  2021-01-03       Impact factor: 2.357

2.  A prospective evaluation of contrast and radiation dose and image quality in cardiac CT in children with complex congenital heart disease using low-concentration iodinated contrast agent and low tube voltage and current.

Authors:  Qiao-Ru Hou; Wei Gao; Ai-Min Sun; Qian Wang; Hai-Sheng Qiu; Fang Wang; Li-Wei Hu; Jian-Ying Li; Yu-Min Zhong
Journal:  Br J Radiol       Date:  2016-12-07       Impact factor: 3.039

Review 3.  Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments.

Authors:  Sandeep S Hedgire; Vinit Baliyan; Brian B Ghoshhajra; Mannudeep K Kalra
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-24

Review 4.  Role of CT in the Pre- and Postoperative Assessment of Conotruncal Anomalies.

Authors:  Parveen Kumar; Mona Bhatia
Journal:  Radiol Cardiothorac Imaging       Date:  2022-06-30

5.  Image quality and radiation dose of dual source high pitch computed tomography in pediatric congenital heart disease.

Authors:  Dmitrij Kravchenko; Christopher Hart; Stephan Garbe; Julian A Luetkens; Alexander Isaak; Narine Mesropyan; Mathieu Vergnat; Judith Leyens; Ulrike Attenberger; Daniel Kuetting
Journal:  Sci Rep       Date:  2022-06-15       Impact factor: 4.996

6.  Evaluation of the CT imaging findings in patients newly diagnosed with chronic thromboembolic pulmonary hypertension.

Authors:  Alexandra Grosse; Claudia Grosse; Irene Lang
Journal:  PLoS One       Date:  2018-07-30       Impact factor: 3.240

7.  320 Slice CT in Imaging of Congenital Heart Diseases in Infants: A Single-Center Experience.

Authors:  Gayathri Sreedher; David Bruckman; Shankar Srinivas Ganapathy
Journal:  Cureus       Date:  2021-02-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.