Radiological protection in computed tomography and cone beam computed tomography.

M M Rehani1.   

Abstract

The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  Computed tomography; Cone beam CT; Patient dose; Radiation protection of patient; Radiological protection

Mesh:

Year:  2015        PMID: 25816279     DOI: 10.1177/0146645315575872

Source DB:  PubMed          Journal:  Ann ICRP        ISSN: 0146-6453


  6 in total

1.  Dose optimization for assessment of periodontal structures in cone beam CT examinations.

Authors:  Ayman Al-Okshi; Chrysoula Theodorakou; Christina Lindh
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

Review 2.  High-Dose Fluoroscopically Guided Procedures in Patients: Radiation Management Recommendations for Interventionalists.

Authors:  Madan M Rehani; Donald L Miller; Vinit Baliyan
Journal:  Cardiovasc Intervent Radiol       Date:  2020-11-12       Impact factor: 2.740

3.  Contemporary issues in radiation protection in medical imaging: introductory editorial.

Authors:  Madan M Rehani; Zoe Brady
Journal:  Br J Radiol       Date:  2021-10       Impact factor: 3.629

4.  Impact of Cone Beam Computed Tomography Dose in Pre-Surgical Implant Analysis.

Authors:  Nabil El Sahili; Ibrahim Nasseh; Antoine Berberi; Sandra David-Tchouda; Sophie Thoret; Thomas Fortin
Journal:  Open Dent J       Date:  2018-01-31

5.  Dosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography.

Authors:  R Ghanbarnezhad Farshi; A Mesbahi; M Johari; Ü Kara; N Gharehaghaji
Journal:  J Biomed Phys Eng       Date:  2019-02-01

6.  Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study.

Authors:  Atul M Padole; Pallavi Sagar; Sjirk J Westra; Ruth Lim; Katherine Nimkin; Mannudeep K Kalra; Michael S Gee; Madan M Rehani
Journal:  Insights Imaging       Date:  2019-09-23
  6 in total