The effect of influence quantities and detector orientation on small-field patient-specific IMRT QA: comparison of measurements with various ionization chambers.

Henry Finlay Godson1,2, Ravikumar Manickam3, Sathiyan Saminathan1, Kadirampatti Mani Ganesh1, Retna Ponmalar1,2.   

Abstract

Intensity-modulated radiation therapy (IMRT) requires a patient-specific quality assurance (QA) program to validate the treatment plan and a high level of dosimetric accuracy in the treatment delivery. Dosimetric verification generally consists of both absolute- and relative-dose measurements in a phantom using ionization chambers. Measurements were carried out with three different ionization chambers (Scanditronix FC 65G, Exradin A18, and PTW PinPoint 31014) to assess the effects of influence quantities such as the stability, pre- and post-irradiation leakage, stem effect, polarity, and ion recombination on the IMRT point-dose verification with two different orientations. The Exradin A18 and PTW PinPoint ion chambers demonstrated noticeable leakage to magnitudes of 0.6 and 1.2%, whereas negligible leakage was observed with FC 65G ion chamber. Maximum deviations of 0.5 and 0.6% were noticed for the smallest field owing to the ion recombination effect with the PTW PinPoint ion chamber in the parallel and perpendicular orientations, respectively. The calculated total uncertainties of all influence quantities for the FC 65G, A18, and PTW PinPoint ion chambers were 0.5, 0.7, and 1.3%, respectively. The uncertainties determined for each chamber were incorporated into the point-dose measurements of 30 head and neck patient-specific QA plans, and the variation was found to be within ±3%. The magnitude of the leakage in a small-volume ion chamber indicated the significance of incorporating the correction factors in the absolute-dose measurement. A paired t test analysis indicated that the influence quantities significantly affect the point-dose measurements in the patient-specific IMRT QA.

Entities:  

Keywords:  Detector orientation; IMRT QA; Influence quantities; Point-dose verification

Mesh:

Year:  2016        PMID: 27910001     DOI: 10.1007/s12194-016-0385-y

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  25 in total

1.  Treatment planning and delivery of intensity-modulated radiation therapy for primary nasopharynx cancer.

Authors:  M A Hunt; M J Zelefsky; S Wolden; C S Chui; T LoSasso; K Rosenzweig; L Chong; S V Spirou; L Fromme; M Lumley; H A Amols; C C Ling; S A Leibel
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-03-01       Impact factor: 7.038

2.  The value of the PinPoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy.

Authors:  C Martens; C De Wagter; W De Neve
Journal:  Phys Med Biol       Date:  2000-09       Impact factor: 3.609

3.  Microionization chamber for reference dosimetry in IMRT verification: clinical implications on OAR dosimetric errors.

Authors:  Francisco Sánchez-Doblado; Roberto Capote; Antonio Leal; Joan V Roselló; Juan I Lagares; Rafael Arráns; Günther H Hartmann
Journal:  Phys Med Biol       Date:  2005-02-17       Impact factor: 3.609

4.  Micro ionization chamber dosimetry in IMRT verification: clinical implications of dosimetric errors in the PTV.

Authors:  Francisco Sánchez-Doblado; Roberto Capote; Joan V Roselló; Antonio Leal; Juan I Lagares; Rafael Arráns; Günther H Hartmann
Journal:  Radiother Oncol       Date:  2005-06       Impact factor: 6.280

5.  Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode.

Authors:  S Agostinelli; S Garelli; M Piergentili; F Foppiano
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

6.  Underestimation of low-dose radiation in treatment planning of intensity-modulated radiotherapy.

Authors:  Si Young Jang; H Helen Liu; Radhe Mohan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-05-29       Impact factor: 7.038

7.  Analysis of patient specific dosimetry quality assurance measurements in intensity modulated radiotherapy: a multi centre study.

Authors:  Rajesh Kumar; S D Sharma; S Deshpande; N V N Madhusudhana Sresty; C P Bhatt; Howard I Amols; G Chourasiya; Y S Mayya
Journal:  J Cancer Res Ther       Date:  2014 Jul-Sep       Impact factor: 1.805

8.  Intensity-modulated radiation therapy in head and neck cancers: The Mallinckrodt experience.

Authors:  K S Chao; D A Low; C A Perez; J A Purdy
Journal:  Int J Cancer       Date:  2000-04-20       Impact factor: 7.396

9.  Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.

Authors:  F Sánchez-Doblado; P Andreo; R Capote; A Leal; M Perucha; R Arráns; L Núñez; E Mainegra; J I Lagares; E Carrasco
Journal:  Phys Med Biol       Date:  2003-07-21       Impact factor: 3.609

10.  Characterization of cylindrical ionization chambers for patient specific IMRT QA.

Authors:  Danielle Fraser; William Parker; Jan Seuntjens
Journal:  J Appl Clin Med Phys       Date:  2009-09-30       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.