Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode.

S Agostinelli1, S Garelli, M Piergentili, F Foppiano.   

Abstract

Since its introduction the PinPoint (PTW-Freiburg) micro-ionization chamber has been proposed for relative dosimetry (output factors, depth dose curves, and beam profiles) as well as for determination of absolute dose of small high-energy photon beams. This paper investigates the dosimetric performance of a new design (type 31014) of the PinPoint ion chamber with a central aluminum electrode. The study included characterization of inherent and radiation-induced leakage, ion collection efficiency and polarity effect, relative response of the chamber, measurement of beam profiles, and depth dose curves. The 6 and 15 MV photon beams of a Varian 2100 C/D were considered. At the nominal operating voltage of 400 V the PinPoint type 31014 chamber was found to present a strong field size dependence of the polarity correction factor and an excess of the collected charge, which can lead to an underestimation of the collection efficiency if determined with the conventional "two-voltage" method. In comparison to the original PinPoint design (type 31006) the authors found for type 31014 chamber no overresponse to large-area fields if polarity correction is applied. If no correction is taken into consideration, the authors found the chamber's output to be inaccurate for large-area fields (0.5% accuracy limited up to the 12 x 12 and 20 x 20 cm2 field for the 6 and 15 MV beams, respectively), which is a direct consequence of the stem and polarity effects due to the chamber's very small sensitive volume (0.015 cc) and cable irradiation. Beam profiles and depth dose curves measured with type 31014 PinPoint chamber for small and medium size fields were compared to data measured with a 0.125 cc ion chamber and with high-resolution Kodak EDR2 films. Analysis of the penumbra (80%-20% distance) showed that the spatial resolution of type 31014 PinPoint ion chamber approaches (penumbra broadening < or = 0.6 mm) EDR2 film results.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18697554     DOI: 10.1118/1.2940190

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Polarity correction factor for flattening filter free photon beams in several cylindrical ionization chambers.

Authors:  Toshiyuki Ogata; Kazuyuki Uehara; Masao Nakayama; Shinji Tsudou; Takashi Masutani; Takanobu Okayama
Journal:  Radiol Phys Technol       Date:  2016-02-12

2.  The effect of influence quantities and detector orientation on small-field patient-specific IMRT QA: comparison of measurements with various ionization chambers.

Authors:  Henry Finlay Godson; Ravikumar Manickam; Sathiyan Saminathan; Kadirampatti Mani Ganesh; Retna Ponmalar
Journal:  Radiol Phys Technol       Date:  2016-12-01

3.  Dosimetric characteristics of the small diameter BrainLab™ cones used for stereotactic radiosurgery.

Authors:  Gocha Khelashvili; James Chu; Aidnag Diaz; Julius Turian
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

4.  A robust measurement point for dose verification in delivery quality assurance for a robotic radiosurgery system.

Authors:  Keita Kurosu; Iori Sumida; Hiroya Shiomi; Hirokazu Mizuno; Hiroko Yamaguchi; Hirofumi Okubo; Keisuke Tamari; Yuji Seo; Osamu Suzuki; Seiichi Ota; Shinichi Inoue; Kazuhiko Ogawa
Journal:  J Radiat Res       Date:  2017-05-01       Impact factor: 2.724

5.  Comparative Study between Measurement Data and Treatment Planning System (TPS) in Small Fields for High Energy Photon Beams.

Authors:  Khaled El Shahat; Aziza El Saeid; Ehab Attalla; Adel Yassin
Journal:  ISRN Oncol       Date:  2014-05-06

6.  Different Dosimeters/Detectors Used in Small-Field Dosimetry: Pros and Cons.

Authors:  Wrya Parwaie; Soheila Refahi; Mahdieh Afkhami Ardekani; Bagher Farhood
Journal:  J Med Signals Sens       Date:  2018 Jul-Sep

7.  Electrometer offset current due to scattered radiation.

Authors:  Sonja Wegener; Otto A Sauer
Journal:  J Appl Clin Med Phys       Date:  2018-10-09       Impact factor: 2.102

8.  Output correction factors for small static fields in megavoltage photon beams for seven ionization chambers in two orientations - perpendicular and parallel.

Authors:  Božidar Casar; Eduard Gershkevitsh; Ignasi Mendez; Slaven Jurković; M Saiful Huq
Journal:  Med Phys       Date:  2019-11-25       Impact factor: 4.071

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.