Literature DB >> 7060600

Design and application of finite impulse response digital filters.

T R Miller, K S Sampathkumaran.   

Abstract

The finite impulse response (FIR) digital filter is a spatial domain filter with a frequency domain representation. The theory of the FIR filter is presented and techniques are described for designing FIR filters with known frequency response characteristics. Rational design principles are emphasized based on characterization of the imaging system using the modulation transfer function and physical properties of the imaged objects. Bandpass, Wiener, and low-pass filters were designed and applied to 201Tl myocardial images. The bandpass filter eliminates low-frequency image components that represent background activity and high-frequency components due to noise. The Wiener, or minimum mean square error filter 'sharpens' the image while also reducing noise. The Wiener filter illustrates the power of the FIR technique to design filters with any desired frequency response. The low-pass filter, while of relative limited use, is presented to compare it with a popular elementary 'smoothing' filter.

Mesh:

Substances:

Year:  1982        PMID: 7060600     DOI: 10.1007/bf00275240

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  4 in total

1.  Letter: On failure to improve observer performance with scan smoothing: a rebuttal.

Authors:  C E Metz; D J Goodenough
Journal:  J Nucl Med       Date:  1973-11       Impact factor: 10.057

2.  Failure to improve observer performance with scan smoothing.

Authors:  D E Kuhl; T D Sanders; R Q Edwards; P T Makler
Journal:  J Nucl Med       Date:  1972-10       Impact factor: 10.057

3.  Improvement of scintigrams by computer processing.

Authors:  S M Pizer; A E Todd-Pokropek
Journal:  Semin Nucl Med       Date:  1978-04       Impact factor: 4.446

4.  Evaluation of computer display systems using digital test patterns.

Authors:  T R Miller; K Sampathkumaran; D R Biello; M W Vannier
Journal:  J Nucl Med       Date:  1981-03       Impact factor: 10.057

  4 in total
  5 in total

1.  EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

Authors:  B Hesse; K Tägil; A Cuocolo; C Anagnostopoulos; M Bardiés; J Bax; F Bengel; E Busemann Sokole; G Davies; M Dondi; L Edenbrandt; P Franken; A Kjaer; J Knuuti; M Lassmann; M Ljungberg; C Marcassa; P Y Marie; F McKiddie; M O'Connor; E Prvulovich; R Underwood; B van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

2.  SPECT volume measurement using an automatic threshold selection method combined with a V filter.

Authors:  K Murase; S Tanada; Y Yasuhara; H Mogami; A Iio; K Hamamoto
Journal:  Eur J Nucl Med       Date:  1989

3.  Interactive reconstruction in single-photon tomography.

Authors:  T R Miller; J W Wallis; A D Wilson
Journal:  Eur J Nucl Med       Date:  1989

4.  Medical display application for degraded image sharpness restoration based on the modulation transfer function: initial assessment for a five-megapixel mammography display monitor.

Authors:  Shogo Tokurei; Yoichiro Ikushima; Kazuki Takegami; Munemasa Okada; Junji Morishita
Journal:  Phys Eng Sci Med       Date:  2021-05-17

5.  Automated determination of the right ventricular ejection fraction by digital processing of 81mKr scintigrams.

Authors:  R Elfner; R Vaknine; W H Knapp; H Tillmanns; W J Lorenz
Journal:  Eur J Nucl Med       Date:  1986
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.