Literature DB >> 6981057

An overview of a camera-based SPECT system.

K L Greer, R J Jaszczak, R E Coleman.   

Abstract

Camera-based single photon emission computed tomography (SPECT) provides increased information about the organ scanned by eliminating superpositioned radionuclidic activity in the reconstructed images. Current literature contains little detail regarding the potential of and the technical aspects involved in using this emerging imaging modality. A description of the instrumentation supplements a general, but practical, background for nuclear medicine personnel. Some of the considerations for successfully utilizing a SPECT system are described, along with a discussion of the basis for these procedures. Pitfalls are mentioned and clinical images from our SPECT imaging system are included.

Mesh:

Year:  1982        PMID: 6981057     DOI: 10.1118/1.595110

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Single photon-emission computed tomography.

Authors:  Thomas A Holly; Brian G Abbott; Mouaz Al-Mallah; Dennis A Calnon; Mylan C Cohen; Frank P DiFilippo; Edward P Ficaro; Michael R Freeman; Robert C Hendel; Diwakar Jain; Scott M Leonard; Kenneth J Nichols; Donna M Polk; Prem Soman
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

2.  Instrumentation quality assurance and performance.

Authors:  Kenneth J Nichols; Stephen L Bacharach; Steven R Bergmann; S James Cullom; Edward P Ficaro; James R Galt; Gary V Heller; Jonathan Links; Josef Machac
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

3.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 4.  Myocardial single-photon emission computed tomographic quality assurance.

Authors:  J M Baron; P Chouraqui
Journal:  J Nucl Cardiol       Date:  1996 Mar-Apr       Impact factor: 5.952

5.  Imagining guidelines for nuclear cardiology procedures. American Society of Nuclear Cardiology. Myocardial perfusion SPECT protocols.

Authors: 
Journal:  J Nucl Cardiol       Date:  1996 May-Jun       Impact factor: 5.952

6.  Interactive reconstruction in single-photon tomography.

Authors:  T R Miller; J W Wallis; A D Wilson
Journal:  Eur J Nucl Med       Date:  1989

Review 7.  Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation.

Authors:  Sharmila Dorbala; Karthik Ananthasubramaniam; Ian S Armstrong; Panithaya Chareonthaitawee; E Gordon DePuey; Andrew J Einstein; Robert J Gropler; Thomas A Holly; John J Mahmarian; Mi-Ae Park; Donna M Polk; Raymond Russell; Piotr J Slomka; Randall C Thompson; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2018-10       Impact factor: 5.952

8.  Neural network reconstruction of single-photon emission computed tomography images.

Authors:  J P Kerr; E B Bartlett
Journal:  J Digit Imaging       Date:  1995-08       Impact factor: 4.056

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.