Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout.

Torsten Diekhoff1,2, Michael Scheel3, Sandra Hermann4, Jürgen Mews5, Bernd Hamm3, Kay-Geert A Hermann3.   

Abstract

OBJECTIVE: Dual-energy computed tomography detects tophi in patients with chronic gout. However, other information that can be obtained from the same scan is not the focus of the current research, e.g., the detection of bone marrow edema (BME) using virtual bone marrow imaging (VBMI). The aim of this study was to evaluate if BME in patients with acute arthritis can be detected with VBMI using magnetic resonance imaging (MRI) as the standard of reference.
MATERIALS AND METHODS: This retrospective study included 11 patients who underwent both MRI and dual-energy computed tomography (mean interval of 40 days). BME in MRI (standard of reference) and VBMI was judged independently by two different blinded readers. φ-correlation coefficient and Cohen's κ were performed for statistical analysis. Approval was waived by the IRB.
RESULTS: Two patients with a final diagnosis of RA and one with septic arthritis showed osteitis on MRI and VBMI. However, in each case, there were individual bones identified with osteitis on MRI but not VBMI. Three additional patients with the final diagnosis of RA were identified correctly as negative for BME. There was a good correlation between both modalities (φ = 0.8; κ = 0.8). Inter-rater reliability was excellent for both modalities (κ = 0.9).
CONCLUSIONS: We have shown that detecting osteitis using VBMI is feasible in patients with inflammatory arthritis. Further studies are needed on larger, more-targeted populations to better define the indications, accuracy, and added value of this technique.

Entities:  

Keywords:  Bone marrow edema; Dual-energy computed tomography; Inflammation; Postprocessing

Mesh:

Year:  2016        PMID: 27872954      PMCID: PMC5177665          DOI: 10.1007/s00256-016-2533-1

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


Introduction

Dual-energy computed tomography (DECT) is known for its ability to detect uric acid tophi in patients with chronic gouty arthritis [1-3]. Therefore, it has become a problem-solving tool in patients with unclassified arthritis and suspicion of crystal arthropathy when deemed necessary based on the clinical presentation [4]. However, DECT has many more possible applications that may be useful for clinical practice, including the virtual non-calcium technique that leads to a virtual bone marrow image (VBMI). The latter yields an image that enables detection of bone marrow edema (BME)—previously only possible with magnetic resonance imaging (MRI) [5]. VBMI is based on a three-material decomposition algorithm that allows subtraction of one material (e.g., calcium) to create an image that virtually consists only of two materials (e.g., fat and soft tissue) [5]. Therefore, the resulting images allow differentiation between adult fatty bone marrow with low attenuation in CT (∼ −100 HU) and increased water content (~0 HU) or displacement of marrow fat. Using an adjusted soft tissue window, the images display fat as black, while BME appears as gray to white. In the last few years, only a few studies have investigated VBMI, and these have focused on trauma imaging, showing that VBMI is able to characterize the age of vertebral fractures [6, 7] and that it is comparable to MRI in displaying bone bruises on the ankle [8]. So far, only one case report published in the literature describes the use of VBMI to detect active inflammation in a patient with suspected sacroiliitis [9]. There is evidence that BME is a strong predictor of progression to bone erosions [10, 11] and cartilage damage [12] in patients with rheumatoid arthritis [13, 14], even if synovitis is a more sensitive parameter of disease activity. Recent studies were able to show that suppression of osteitis in patients with rheumatoid arthritis goes along with suppression of structural progress, e.g., erosions [15, 16]. Studies on bone remodeling suggest that osteitis in MRI is a sign of increased RANKL expression, which leads to osteoclastic bone resorption [17]. However, not all patients with suspected arthritis may be able to undergo MRI of the hands or feet due to various contraindications [18]. Finally, ultrasound has its role in visualizing extraosseous pathology such as synovitis and bone erosion, while intraosseous processes, especially BME, are hidden to the ultrasound probe [19]. We hypothesize that VBMI is able to identify osteitis. Thus, the aim of this study was to evaluate if BME in patients with acute arthritis can be detected with VBMI using magnetic resonance imaging (MRI) as a standard of reference.

Materials and methods

We retrospectively identified all patients with suspected gout who underwent DECT in the period from September 2011 through July 2014 and additionally had an MRI of the same anatomical region. All patients had an unclear clinical presentation and suspicion of gouty arthritis that occurred either when first presenting at our hospital or later in the course of the treatment. DECT was performed to search for gouty tophi, and MRI in clinical routine to detect inflammatory changes. The report database and hospital PACS (picture archiving and communication system) were used to find those examinations. From the 24 patients who met these criteria, we selected those who had an interval of 3 months or less between DECT and MRI. Eleven patients (six men and five women aged from 45 to 81 years (mean age, 62.2 years) with an interval of 0–82 days (mean, 40 days) between examinations met our criteria and were included. Details of the study population are summarized in Table 1.
Table 1

Patients’ characteristics, examination, and diagnosis

No.AgeIntervalRegionmADLPEEDDiagnosisMRI+VBMI+
18166 *Fingers15/9024.10.019Seropositive RA00
24534Feet25/14038.50.008Seropositive RA8a 8a
37412Fingers25/14038.50.031Seronegative RA21
46950Wrist15/9024.10.019CPPD00
5467 *Fingers30/17046.60.037Seronegative RA00
6690Fingers20/11030.50.024Seronegative RA00
76341 *Wrist20/11030.50.024CPPD00
86382Wrist20/11030.50.024CPPD00
95249Foot15/9024.10.005Gouty arthritis00
105975Foot25/14038.50.008Bone infarction11
116323 *Ankle15/9024.10.005Infectious arthritis42

No. patients’ number; Interval interval between MRI and DECT or vice versa in days, * indicating that MRI was performed after DECT; Region examined body part; mA applied tube current for DECT examination for 135 and 80 kV, DLP dose-length product in mGy*cm; EED estimated effective dose in mSv using a conversion coefficient of 0.0008 for the upper extremities and 0.0002 for feet and ankles. Diagnosis final diagnosis made by the rheumatologist (RA rheumatoid arthritis; CPPD calcium pyrophosphate dihydrate crystal deposition disease); MRI+ number of bones with BME in MRI; VBMI+ number of bones with BME in DECT. aFor patient No. 2, there is one false-positive and one false-negative detection in VBMI

Patients’ characteristics, examination, and diagnosis No. patients’ number; Interval interval between MRI and DECT or vice versa in days, * indicating that MRI was performed after DECT; Region examined body part; mA applied tube current for DECT examination for 135 and 80 kV, DLP dose-length product in mGy*cm; EED estimated effective dose in mSv using a conversion coefficient of 0.0008 for the upper extremities and 0.0002 for feet and ankles. Diagnosis final diagnosis made by the rheumatologist (RA rheumatoid arthritis; CPPD calcium pyrophosphate dihydrate crystal deposition disease); MRI+ number of bones with BME in MRI; VBMI+ number of bones with BME in DECT. aFor patient No. 2, there is one false-positive and one false-negative detection in VBMI DECT scans were obtained on a 320-row scanner (Toshiba Aquilion ONETM and from September 2013 Toshiba Aquilion ONE VisionTM; Toshiba, Otawara, Japan) with 16-cm z-axis coverage without table movement using 135-kVp (high) and 80-kVp (low) tube voltage [3]. The applied tube current and the resulting radiation exposure depended on the availability of iterative reconstructions (since 2013), patients’ physique, and the examined region (see Table 1 for details). For image processing, we used proprietary virtual non-contrast software (dual-energy image view, Version 6, Toshiba, Otawara, Japan) with an adapted dual-energy gradient of 0.69 for calcium. This software is commercially available for Toshiba CT machines, e.g., Aquilion Prime or Aquilion One Vision. Object formulas for the three-material decomposition algorithm were −136/-106 (80/135 kV) for fat and 0/0 for water. A Gaussian noise reduction filter was applied. VBMI images were created in 0.5-mm slices and 5-mm averaged multiplanar reconstructions. We included MR images from different scanners and hospitals (1.5–3 Tesla) acquired using different coils (knee, hand, and flex-coil) into our analysis. An evaluation before study inclusion by reader 1 found all images to be diagnostic and not impaired by severe artifacts, e.g., due to metal implants. The MRI protocol was not the same for all patients but included at least one fat-saturated T2-weighted or fat-saturated proton density (PD) weighted sequence, which can be evaluated for the presence of BME. Slice orientation varied amongst the examinations. However, usually coronal or sagittal images were available. Both readers (reader 1: junior radiologist with 5 years experience in image reading; reader 2: senior radiologist with 14 years experience) independently interpreted the images with an interval of at least 6 months between the reading of MR and VBMI. They used a workstation with a high-resolution monitor and OsiriX Version 5 (Pixmeo SARL, Bernex, Switzerland). The readers were blinded to clinical data, results, and images of the other imaging modality. They had access to all images of the examination including conventional multiplanar CT reconstructions (DECT) or T1 sequences (MRI). Each bone displayed in both imaging techniques was scored as BME-negative or BME-positive. A bone was counted as BME positive if both readers agreed in the presence of edema. Furthermore, the readers documented potential artifacts, e.g., due to incomplete fat saturation in MRI. Statistical analysis was performed using GraphPad Prism (Version 6, La Jolla, CA, USA) and included the calculation of the φ correlation coefficient and Cohen’s κ to compare both imaging techniques. Cohen’s κ was also used to calculate the inter-rater reliability. The patients’ final diagnoses were established by an expert rheumatologist based on clinical presentation, laboratory findings, and imaging results. For patient No. 11, additionally a joint aspiration was performed. The local ethics committee waived the approval of this retrospective study.

Results

We identified 188 bones that were displayed in both MRI and VBMI. Thirty-eight bones in a total of six patients were excluded because of MRI artifacts with subsequent incomplete fat saturation, resulting in a total of 150 bones that were included in our analysis. All artifacts were caused by inhomogeneity of the magnetic field, e.g., at the tip of the toes. There were no artifacts in the VBMI reconstructions impeding image interpretation. There were five patients with a final diagnosis of rheumatoid arthritis, two with and three without osteitis in MRI, involving ten bones in total. VBMI correctly identified osteitis in both positive patients (seven true-positive, two false-negative, and one false-positive bone) and correctly showed the absence of osteitis in the three negative patients. One patient with infectious arthritis showed osteitis in MRI and VBMI, however, VBMI identified only two out of four affected bones. The bone marrow changes of another patient with bone infarction was detected by both MRI and VBMI. The other patients with the final diagnosis of crystal arthropathy showed no BME in either of the modalities. The false-negative results in VBMI occurred as discreet BME of the proximal phalanx 5 of the tarsus (patient No. 2), the intermediate phalanx 4 (patient No. 3), and the distal fibula and tibia (patient No. 11) in MRI. There was one false-positive detection in the metatarsal head (patient No. 2), as shown in Fig. 1. However, on the patients’ level, there were no false-positive or false-negative detections using VBMI. This means, each patient showing BME in MRI was detected by VBMI and each patient without BME in MRI was negative using DECT, respectively.
Fig. 1

Left foot of patient No. 2 (seropositive RA). CT: normal CT image at 135 kV, VBMI: corresponding VBMI image, MRI: corresponding fat-saturated T2 sequence – multiplanar reformatted VBMI shows a good correlation to the corresponding MRI with regard to the identification of BME at the first, second, and fifth metatarsophalangeal joint (arrowheads). However, in MRI, there are artifacts due to incomplete fat saturation in the second and third toes (arrows). The corresponding CT image appearance is normal

Left foot of patient No. 2 (seropositive RA). CT: normal CT image at 135 kV, VBMI: corresponding VBMI image, MRI: corresponding fat-saturated T2 sequence – multiplanar reformatted VBMI shows a good correlation to the corresponding MRI with regard to the identification of BME at the first, second, and fifth metatarsophalangeal joint (arrowheads). However, in MRI, there are artifacts due to incomplete fat saturation in the second and third toes (arrows). The corresponding CT image appearance is normal The φ correlation coefficient was 0.8 and Cohen’s κ was 0.8, indicating good agreement of both imaging methods. Inter-rater agreement was excellent for both modalities (MRI κ = 0.87, VBMI κ = 0.88). Figures 1, 2, 3, and 4 provide examples of true-positive, false-positive, and false-negative findings.
Fig. 2

Right foot of patient No. 2 (seropositive RA). CT: normal CT image at 135 kV, VBMI: corresponding VBMI image, MRI: corresponding fat-saturated T2 sequence – VBMI displays the BME in the fourth metatarsal head (arrowheads) with erosions and cysts in CT. In the first metatarsal head, VBMI is false positive compared to MRI (arrow)

Fig. 3

Right wrist of patient No. 7 (CPPD). CT: normal CT image at 135 kV, VBMI: corresponding VBMI image, MRI: corresponding short tau inversion recovery sequence – MRI shows a faint BME in the lunate (arrow) that was missed by reader 1. VBMI also displays a slight hyperdensity, which was scored negative by both readers because even normal carpal bones yield increased density in VBMI compared to long bones according to our clinical experience

Fig. 4

Right ankle of patient No. 11 (infectious arthritis). CT: normal CT image at 135 kV, VBMI: corresponding VBMI image, MRI: corresponding fat-saturated PD sequence – MRI shows pronounced edema in the distal tibia, fibula and calcaneus (arrowheads). The osteitis in the distal fibula and tibia was missed by reader 2 in VBMI. Nonetheless, VBMI depicts the edema in the distal tibia to a lesser extent compared to MRI (arrow)

Right foot of patient No. 2 (seropositive RA). CT: normal CT image at 135 kV, VBMI: corresponding VBMI image, MRI: corresponding fat-saturated T2 sequence – VBMI displays the BME in the fourth metatarsal head (arrowheads) with erosions and cysts in CT. In the first metatarsal head, VBMI is false positive compared to MRI (arrow) Right wrist of patient No. 7 (CPPD). CT: normal CT image at 135 kV, VBMI: corresponding VBMI image, MRI: corresponding short tau inversion recovery sequence – MRI shows a faint BME in the lunate (arrow) that was missed by reader 1. VBMI also displays a slight hyperdensity, which was scored negative by both readers because even normal carpal bones yield increased density in VBMI compared to long bones according to our clinical experience Right ankle of patient No. 11 (infectious arthritis). CT: normal CT image at 135 kV, VBMI: corresponding VBMI image, MRI: corresponding fat-saturated PD sequence – MRI shows pronounced edema in the distal tibia, fibula and calcaneus (arrowheads). The osteitis in the distal fibula and tibia was missed by reader 2 in VBMI. Nonetheless, VBMI depicts the edema in the distal tibia to a lesser extent compared to MRI (arrow)

Discussion

In our small retrospective feasibility study, we were able to show that VBMI can detect osteitis in arthritis patients. The first results indicate a high sensitivity and specificity compared to MRI as standard of reference. Despite missing 20 % of the edema looking at single bones, all patients with BME were detected by DECT in our small cohort. The depiction of BME using VBMI may be of added value in patients undergoing a clinical DECT scan of the extremities. DECT is an emerging technique for gaining information on material composition and physical properties of a certain tissue. In clinical practice, it is not only used to detect gouty tophi or characterize renal stones [20] but has also evolved into a tool for mapping iodine concentrations and the distribution of contrast media or for virtually subtracting contrast medium or bone of an image [21, 22]. DECT analysis of bone marrow using VBMI is another promising application for detecting BME not only in trauma or arthritis but also in malignant bone infiltration, where the technique allows estimating the permeative extension of primary bone tumor cells into normal-appearing bone marrow [23]. VBMI information is obtained by using a three-material decomposition algorithm that is able to virtually eliminate the information of calcium attenuation out of an image. In graphical terms, this can be achieved by projecting all voxels on a graph showing the attenuation of the voxel at high and low kV images parallel to the calcium gradient to a line determined by the specific object formulas of water and fat. The result is an image that is virtually based on the water and fat attenuations only and does not include the calcium information. Therefore, differences in density are related to different water and fat contents allowing to search for BME. The fact that 38 out of 188 bones (or 20 %) in our small collective had to be excluded from analysis due to incomplete fat saturation in MRI indicates that positioning in the MRI machine plays an important role—especially for the appendicular skeleton—and is sometimes complex [24]. Incomplete fat saturation may mimic BME. Therefore, a high signal in fat-saturated MR images must be interpreted with caution. However, VBMI is independent of a homogeneous magnetic field and therefore such artifacts are considerably less frequent. Nonetheless, VBMI uses X-rays and is therefore associated with radiation exposure. However, the investigated appendicular skeleton is far away from the radiosensitive organs such as eye lens or thyroid gland. Furthermore, the examined volume of hands and feet is considerably smaller than for example the abdomen resulting in less radiation for the same image quality. This results in a small conversion coefficient that was recently decreased for the lower extremities using new phantom measurements [25]. In our analysis, we had four false-negative results in VBMI. Mostly, these edemas detected by MRI were rather faint and small in size. Thus, they are more likely to be missed by VBMI. On the other hand, there is a rather long time interval between both imaging modalities in those cases, also in the false-positive detection on the right metatarsal bone. Therefore, the hypothesis can be made that edema might be altered due to treatment effects or worsening of the disease. This study is a feasibility test and suffers from all limitations inherent to a retrospective design including the use of different imaging protocols and variable intervals between the examinations. However, at least for DECT, there is some evidence that radiation dose does not significantly affect the detection of BME [26]. Furthermore, our patient sample is small and heterogeneous, including complex cases and different diagnoses. This is why the first imaging test was inconclusive and both DECT and MRI were performed to secure the diagnosis. This leads to a lack of power, and statistical analysis performed in this study should therefore be treated with caution. Moreover, there was a low overall prevalence of BME in our study. This may be caused by the conservative statistical evaluation counting a bone only as positive if both readers found osteitis. We also did not collect information about the extent and severity of BME in this study. Therefore, it is left to further evaluations to determine if MRI and VBMI are comparable in depicting the degree of osteitis in patients with arthritis. Our study gives first evidence that DECT with VBMI is capable of identifying osteitis in patients with active arthritis, so far only possible with MRI, and thus can provide additional information that may be derived from DECT scans. Furthermore, DECT may be an inexpensive and fast alternative to MRI and a useful supplement to ultrasound. Therefore, prospective data should be acquired to prove the benefit of VBMI in diagnosing arthritis in clinical practice.
  26 in total

1.  MRI bone oedema predicts eight year tendon function at the wrist but not the requirement for orthopaedic surgery in rheumatoid arthritis.

Authors:  S Zheng; E Robinson; S Yeoman; N Stewart; J Crabbe; J Rouse; F M McQueen
Journal:  Ann Rheum Dis       Date:  2005-10-11       Impact factor: 19.103

2.  2012 American College of Rheumatology guidelines for management of gout. Part 1: systematic nonpharmacologic and pharmacologic therapeutic approaches to hyperuricemia.

Authors:  Dinesh Khanna; John D Fitzgerald; Puja P Khanna; Sangmee Bae; Manjit K Singh; Tuhina Neogi; Michael H Pillinger; Joan Merill; Susan Lee; Shraddha Prakash; Marian Kaldas; Maneesh Gogia; Fernando Perez-Ruiz; Will Taylor; Frédéric Lioté; Hyon Choi; Jasvinder A Singh; Nicola Dalbeth; Sanford Kaplan; Vandana Niyyar; Danielle Jones; Steven A Yarows; Blake Roessler; Gail Kerr; Charles King; Gerald Levy; Daniel E Furst; N Lawrence Edwards; Brian Mandell; H Ralph Schumacher; Mark Robbins; Neil Wenger; Robert Terkeltaub
Journal:  Arthritis Care Res (Hoboken)       Date:  2012-10       Impact factor: 4.794

3.  Estimates of effective dose for CT scans of the lower extremities.

Authors:  Natalia Saltybaeva; Mary Ellen Jafari; Martin Hupfer; Willi A Kalender
Journal:  Radiology       Date:  2014-06-16       Impact factor: 11.105

4.  Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies.

Authors:  Torsten Diekhoff; Tobias Kiefer; Andrea Stroux; Irid Pilhofer; Ralf Juran; Jürgen Mews; Jörg Blobel; Masaharu Tsuyuki; Beate Ackermann; Bernd Hamm; Kay-Geert A Hermann
Journal:  Invest Radiol       Date:  2015-04       Impact factor: 6.016

5.  Iodine quantification using dual-energy multidetector computed tomography imaging: phantom study assessing the impact of iterative reconstruction schemes and patient habitus on accuracy.

Authors:  Sebastian Feuerlein; Tobias J Heye; Mustafa R Bashir; Daniel T Boll
Journal:  Invest Radiol       Date:  2012-11       Impact factor: 6.016

6.  Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions--feasibility study.

Authors:  Gregor Pache; Bernhard Krauss; Peter Strohm; Ulrich Saueressig; Philipp Blanke; Stefan Bulla; Oliver Schäfer; Peter Helwig; Elmar Kotter; Mathias Langer; Tobias Baumann
Journal:  Radiology       Date:  2010-06-15       Impact factor: 11.105

7.  Prediction of MRI erosive progression: a comparison of modern imaging modalities in early rheumatoid arthritis patients.

Authors:  Pernille Bøyesen; Espen A Haavardsholm; Désirée van der Heijde; Mikkel Østergaard; Hilde Berner Hammer; Sølve Sesseng; Tore K Kvien
Journal:  Ann Rheum Dis       Date:  2010-11-10       Impact factor: 19.103

8.  Dual energy computed tomography in tophaceous gout.

Authors:  H K Choi; A M Al-Arfaj; A Eftekhari; P L Munk; K Shojania; G Reid; S Nicolaou
Journal:  Ann Rheum Dis       Date:  2008-12-09       Impact factor: 19.103

9.  MRI osteitis predicts cartilage damage at the wrist in RA: a three-year prospective 3T MRI study examining cartilage damage.

Authors:  Fiona M McQueen; Alexandra McHaffie; Andrew Clarke; Arier C Lee; Quentin Reeves; Barbara Curteis; Nicola Dalbeth
Journal:  Arthritis Res Ther       Date:  2014-01-30       Impact factor: 5.156

10.  The effects of tocilizumab on osteitis, synovitis and erosion progression in rheumatoid arthritis: results from the ACT-RAY MRI substudy.

Authors:  Philip G Conaghan; Charles Peterfy; Ewa Olech; Jeffrey Kaine; David Ridley; Julie Dicarlo; Josh Friedman; Jenny Devenport; Orrin Troum
Journal:  Ann Rheum Dis       Date:  2014-02-13       Impact factor: 19.103

View more
  9 in total

Review 1.  Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis.

Authors:  Chong Hyun Suh; Seong Jong Yun; Wook Jin; Sun Hwa Lee; So Young Park; Chang-Woo Ryu
Journal:  Eur Radiol       Date:  2018-04-20       Impact factor: 5.315

2.  Dual-energy CT in the differentiation of crystal depositions of the wrist: does it have added value?

Authors:  Katharina Ziegeler; Sandra Hermann; Kay Geert A Hermann; Bernd Hamm; Torsten Diekhoff
Journal:  Skeletal Radiol       Date:  2019-12-04       Impact factor: 2.199

3.  Dual energy CT iodine map for delineating inflammation of inflammatory arthritis.

Authors:  Takeshi Fukuda; Yoshinori Umezawa; Akihiko Asahina; Hidemi Nakagawa; Kazuhiro Furuya; Kunihiko Fukuda
Journal:  Eur Radiol       Date:  2017-07-03       Impact factor: 5.315

Review 4.  Dual energy CT in musculoskeletal applications beyond crystal imaging: bone marrow maps and metal artifact reduction.

Authors:  Gaurav Cheraya; Salil Sharma; Avneesh Chhabra
Journal:  Skeletal Radiol       Date:  2022-02-02       Impact factor: 2.199

5.  Ultra-low-dose CT detects synovitis in patients with suspected rheumatoid arthritis.

Authors:  Torsten Diekhoff; Sevtap Tugce Ulas; Denis Poddubnyy; Udo Schneider; Sandra Hermann; Robert Biesen; Gerd R Burmester; Bernd Hamm; Kay Geert Hermann
Journal:  Ann Rheum Dis       Date:  2018-09-29       Impact factor: 19.103

Review 6.  Future of Low-Dose Computed Tomography and Dual-Energy Computed Tomography in Axial Spondyloarthritis.

Authors:  Torsten Diekhoff; Kay Geert A Hermann; Robert G Lambert
Journal:  Curr Rheumatol Rep       Date:  2022-04-09       Impact factor: 4.686

7.  Contrast-enhanced CT techniques and MRI perform equally well in arthritis imaging of the hand: a prospective diagnostic accuracy study.

Authors:  Sevtap Tugce Ulas; Katharina Ziegeler; Sophia-Theresa Richter; Sarah Ohrndorf; Robert Biesen; Fabian Proft; Denis Poddubnyy; Torsten Diekhoff
Journal:  Eur Radiol       Date:  2022-04-01       Impact factor: 7.034

8.  Virtual Monochromatic Images from Dual-Energy Computed Tomography Do Not Improve the Detection of Synovitis in Hand Arthritis.

Authors:  Sevtap Tugce Ulas; Katharina Ziegeler; Sophia-Theresa Richter; Sarah Ohrndorf; Fabian Proft; Denis Poddubnyy; Torsten Diekhoff
Journal:  Diagnostics (Basel)       Date:  2022-08-04

9.  Dual-energy CT collagen density mapping of wrist ligaments reveals tissue remodeling in CPPD patients: first results from a clinical cohort.

Authors:  Katharina Ziegeler; Sophia-Theresa Richter; Sandra Hermann; Kay Geert A Hermann; Bernd Hamm; Torsten Diekhoff
Journal:  Skeletal Radiol       Date:  2020-08-15       Impact factor: 2.199

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.