Estimates of effective dose for CT scans of the lower extremities.

Natalia Saltybaeva1, Mary Ellen Jafari, Martin Hupfer, Willi A Kalender.   

Abstract

PURPOSE: To determine the dose-length product (DLP)-effective dose (ED) (DLP/ED) conversion coefficient (k) tables for the lower extremities that can be used for calculating ED.
MATERIALS AND METHODS: Dose calculations were performed on standard phantoms using a validated Monte Carlo calculation tool. Calculations were performed to obtain ED values for tube voltages from 80 kV to 140 kV in steps of 20 kV for the following examinations: hip (femur), knee, ankle, and computed tomographic (CT) angiography of the lower extremities. Values of the DLP were calculated by multiplying measured CT dose index values by the scan length; k values resulted as the quotients of the ED and DLP values. DLP/ED coefficients averaged over the range of voltage values and their standard deviations were determined for the given lower-extremity CT examinations for all age groups and for both sexes.
RESULTS: Coefficients depend strongly on the phantom age and size, but little on the kilovolt value. In the case of the newborn, for example, k values were 0.0612, 0.0046, 0.0014, and 0.047 for hip, knee, ankle, and CT angiography, respectively, while in the case of the adult, these respective values were 0.0110, 0.0004, 0.0002, and 0.0062. A substantial difference up to 20% between coefficients in male and female phantoms was observed for CT angiographic examination.
CONCLUSION: DLP/ED conversion coefficients are provided for lower extremities and allow estimation of ED for commonly used clinical musculoskeletal CT and CT angiographic protocols. © RSNA, 2014.

Mesh:

Year:  2014        PMID: 24937693     DOI: 10.1148/radiol.14132903

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  37 in total

1.  Three-dimensional biplanar radiography as a new means of accessing femoral version: a comparitive study of EOS three-dimensional radiography versus computed tomography.

Authors:  M Lucius Pomerantz; Diana Glaser; Josh Doan; Sita Kumar; Eric W Edmonds
Journal:  Skeletal Radiol       Date:  2014-10-17       Impact factor: 2.199

2.  Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff: impact on diagnostic accuracy for stenosis detection.

Authors:  Domenico De Santis; Carlo N De Cecco; U Joseph Schoepf; John W Nance; Ricardo T Yamada; Brooke A Thomas; Katharina Otani; Brian E Jacobs; D Alan Turner; Julian L Wichmann; Marwen Eid; Akos Varga-Szemes; Damiano Caruso; Katharine L Grant; Bernhard Schmidt; Thomas J Vogl; Andrea Laghi; Moritz H Albrecht
Journal:  Eur Radiol       Date:  2019-02-25       Impact factor: 5.315

Review 3.  Radiation dose in non-dental cone beam CT applications: a systematic review.

Authors:  Cosimo Nardi; Sergio Salerno; Roberto Molteni; Mariaelena Occhipinti; Giulia Grazzini; Niccolò Norberti; Cesare Cordopatri; Stefano Colagrande
Journal:  Radiol Med       Date:  2018-06-05       Impact factor: 3.469

4.  Bloodpool SPECT as part of bone SPECT/CT in painful total knee arthroplasty (TKA): validation and potential biomarker of prosthesis biomechanics.

Authors:  Jolien Verschueren; Adrien Albert; Laurens Carp; Sarah Ceyssens; Ivan Huyghe; Sigrid Stroobants; Frédéric Paycha; Gopinath Gnanasegaran; Tim Van den Wyngaert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-01-02       Impact factor: 9.236

5.  Evaluation of Effective Dose from CT Scans for Overweight and Obese Adult Patients Using the VirtualDose Software.

Authors:  Baohui Liang; Yiming Gao; Zhi Chen; X George Xu
Journal:  Radiat Prot Dosimetry       Date:  2017-04-25       Impact factor: 0.972

6.  Application of High-Speed Dual Fluoroscopy to Study In Vivo Tibiotalar and Subtalar Kinematics in Patients With Chronic Ankle Instability and Asymptomatic Control Subjects During Dynamic Activities.

Authors:  Koren E Roach; K Bo Foreman; Alexej Barg; Charles L Saltzman; Andrew E Anderson
Journal:  Foot Ankle Int       Date:  2017-08-11       Impact factor: 2.827

7.  Effect of iterative reconstruction techniques on image quality in low radiation dose chest CT: a phantom study.

Authors:  Yan Xu; Ting-Ting Zhang; Zhi-Hai Hu; Juan Li; Hong-Jun Hou; Zu-Shan Xu; Wen He
Journal:  Diagn Interv Radiol       Date:  2019-11       Impact factor: 2.630

8.  First experience with single-source dual-energy computed tomography in six patients with acute arthralgia: a feasibility experiment using joint aspiration as a reference.

Authors:  Torsten Diekhoff; Katharina Ziegeler; Eugen Feist; Tobias Kiefer; Jürgen Mews; Bernd Hamm; Kay-Geert A Hermann
Journal:  Skeletal Radiol       Date:  2015-07-05       Impact factor: 2.199

9.  Quantification of osteoblastic activity in epiphyseal growth plates by quantitative bone SPECT/CT.

Authors:  Tomohiko Yamane; Ichiei Kuji; Akira Seto; Ichiro Matsunari
Journal:  Skeletal Radiol       Date:  2018-01-11       Impact factor: 2.199

10.  Dual-energy CT in the differentiation of crystal depositions of the wrist: does it have added value?

Authors:  Katharina Ziegeler; Sandra Hermann; Kay Geert A Hermann; Bernd Hamm; Torsten Diekhoff
Journal:  Skeletal Radiol       Date:  2019-12-04       Impact factor: 2.199

View more