Literature DB >> 24834889

Dual-energy computed tomographic virtual noncalcium algorithm for detection of bone marrow edema in acute fractures: early experiences.

Adrian C Reagan1, Paul I Mallinson, Timothy O'Connell, Patrick D McLaughlin, Bernhard Krauss, Peter L Munk, Savvas Nicolaou, Hugue A Ouellette.   

Abstract

Computed tomography (CT) is often used to assess the presence of occult fractures when plain radiographs are equivocal in the acute traumatic setting. While providing increased spatial resolution, conventional computed tomography is limited in the assessment of bone marrow edema, a finding that is readily detectable on magnetic resonance imaging (MRI).Dual-energy CT has recently been shown to demonstrate patterns of bone marrow edema similar to corresponding MRI studies. Dual-energy CT may therefore provide a convenient modality for further characterizing acute bony injury when MRI is not readily available. We report our initial experiences of 4 cases with imaging and clinical correlation.

Entities:  

Mesh:

Year:  2014        PMID: 24834889     DOI: 10.1097/RCT.0000000000000107

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  5 in total

1.  Acute vertebral fracture after spinal fusion: a case report illustrating the added value of single-source dual-energy computed tomography to magnetic resonance imaging in a patient with spinal Instrumentation.

Authors:  M Fuchs; M Putzier; M Pumberger; K G Hermann; T Diekhoff
Journal:  Skeletal Radiol       Date:  2016-06-07       Impact factor: 2.199

Review 2.  Clinical utility of virtual noncalcium dual-energy CT in imaging of the pelvis and hip.

Authors:  Francis I Baffour; Katrina N Glazebrook; Jonathan M Morris; Gregory J Michalak; Joel G Fletcher; Shuai Leng; Cynthia H McCollough
Journal:  Skeletal Radiol       Date:  2019-05-30       Impact factor: 2.199

3.  Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study.

Authors:  Torsten Diekhoff; Nils Engelhard; Michael Fuchs; Matthias Pumberger; Michael Putzier; Jürgen Mews; Marcus Makowski; Bernd Hamm; Kay-Geert A Hermann
Journal:  Eur Radiol       Date:  2018-06-15       Impact factor: 5.315

4.  Single-source dual-energy computed tomography for the detection of bone marrow lesions: impact of iterative reconstruction and algorithms.

Authors:  N Engelhard; K G Hermann; J Greese; M Fuchs; M Pumberger; M Putzier; T Diekhoff
Journal:  Skeletal Radiol       Date:  2019-12-10       Impact factor: 2.199

5.  Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout.

Authors:  Torsten Diekhoff; Michael Scheel; Sandra Hermann; Jürgen Mews; Bernd Hamm; Kay-Geert A Hermann
Journal:  Skeletal Radiol       Date:  2016-11-21       Impact factor: 2.199

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.