| Literature DB >> 35359165 |
Sevtap Tugce Ulas1, Katharina Ziegeler1, Sophia-Theresa Richter1, Sarah Ohrndorf2, Robert Biesen2, Fabian Proft3, Denis Poddubnyy3, Torsten Diekhoff4.
Abstract
OBJECTIVES: To investigate the performance of dual-energy CT (DECT)-generated iodine maps (iMap) and CT subtraction (CT-S) in the detection of synovitis, tenosynovitis, and peritendonitis/paratenonitis compared to magnetic resonance imaging (MRI) using musculoskeletal ultrasound (MSUS) as standard of reference.Entities:
Keywords: Arthritis, rheumatoid; Computed tomography; Dual energy; Magnetic resonance imaging; Ultrasound
Mesh:
Substances:
Year: 2022 PMID: 35359165 PMCID: PMC9381445 DOI: 10.1007/s00330-022-08744-0
Source DB: PubMed Journal: Eur Radiol ISSN: 0938-7994 Impact factor: 7.034
Fig. 1Flowchart of study inclusion and results of RAMRIS scoring. MSUS = musculoskeletal ultrasound, DECT = dual-energy CT, iMap-I = image-based iodine map DECT, iMap-RD = raw data-based iodine map DECT, CT-S = CT subtraction, MRI = magnetic resonance imaging, RA(+) = seropositive rheumatoid arthritis, RA(−) = seronegative rheumatoid arthritis, PsA = psoriatic arthritis, OA = osteoarthritis, CPPD = calcium pyrophosphate deposition disease, LSS = limited systemic sclerosis
Fig. 2Imaging examples in coronal and axial orientation. MRI (T1fs Gd+) = fat-saturated contrast-enhanced T1-weighted sequence MRI; iMap-I = image data-based dual-energy CT iodine map; iMap-RD = raw data-based dual-energy CT iodine map; CT-S = CT subtraction. Patient A: a 50-year-old female patient with initial seronegative rheumatoid arthritis during therapy. No inflammatory joint changes were detected, e.g., in metacarpophalangeal joint II (MCP) (arrowhead). Note the partial volume effect at the bone and skin border (arrow). Patient B: a 55-year-old female patient with seronegative rheumatoid arthritis. There is severe synovitis in MCP V (arrowhead) and of the radiocarpal joint (arrow). Furthermore, severe tenosynovitis of the flexor tendons II–V was detected in all modalities (arrows), while iMap-I tends to underestimate the tenosynovitis III (arrow) and CT-S tenosynovitis V (arrow)
Results of contingency table analysis with 95% CI of the (modified) RAMRIS synovitis score. MSUS musculoskeletal ultrasound, DECT dual-energy CT, iMap-I image-based iodine map DECT, iMap-RD raw data-based iodine map DECT, CT-S CT subtraction, MRI magnetic resonance imaging, SE sensitivity, SP specificity, PPV positive predictive value, NPV negative predictive value