Rushad Shroff1, Mathew Francis2, Natasha Pahuja1, Leio Veeboy2, Rohit Shetty3, Abhijit Sinha Roy4.
Abstract
PURPOSE: To quantitatively evaluate microdistortions in Bowman's layer and change in corneal stiffness after small incision lenticule extraction (SMILE).Entities:
Keywords: diffractive multifocal IOL; trifocal IOL; vision simulator; visual acuity; visual impression
Year: 2016 PMID: 27777827 PMCID: PMC5072544 DOI: 10.1167/tvst.5.5.12
Source DB: PubMed Journal: Transl Vis Sci Technol ISSN: 2164-2591 Impact factor: 3.283
Figure 1Optical coherence tomography (raw) image of Bowman's layer after SMILE (top figure). Pink line is the actual Bowman's layer edge and green line is curve fit to the pink line. Curve fit was performed with a third order polynomial equation on the segmented edge with microdistortions. The shaded areas are shown in the bottom figure and represent the areas enclosed between the segmented Bowman's layer edge and the smooth polynomial fit. Bowman Roughness Index is the sum of all the shaded areas in the bottom figure.
Figure 2A spring-dashpot model to describe corneal and extra-ocular tissue deformation caused by air-puff applanation. Kc and Kg are the corneal and extra-ocular tissue stiffnesses, respectively. μg is the viscosity of the extra-ocular tissue. u1 and u2 are the deformation amplitude and deformation of the extra-ocular tissue, respectively. Fair-puff is the force applied by the air-puff.
Figure 3Mean BRI before, 1 day after, 1 week after, and 1 month after surgery. There was a statistically significant difference (P < 0.0001) between all time points.
Figure 4An example of measured versus model fit (described by equation [4]) to deformation amplitude (top left), corneal deformation (top right), extra-ocular tissue deformation (bottom left), and applanation pressure (bottom right).
Figure 5Corneal stiffness versus applanation pressure before and after surgery in all the treated eyes is shown in the top figure. The continuous lines are regressions of the preoperative (solid line) and postoperative (dotted line) data (top figure). The bottom figure shows the mean corneal stiffness before and 1 month after surgery. * Indicates statistically significant difference (P = 0.001) before and after surgery in mean corneal stiffness.