PURPOSE: To compare the corneal biomechanical properties before and after small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK in different levels of myopia with the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Depew, NY).
METHODS: A total of 187 and 79 eyes that received SMILE or LASIK, respectively, between January and June 2013 at Zhongshan Ophthalmic Center were enrolled in this study. Patients were grouped according to surgery type (SMILE or LASIK) and -6.00 diopters (D) or less (> -6.00 D) or myopia greater than -6.00 D (>-6.00 D). Corneal hysteresis, corneal resistance factor, and 37 waveform parameters were recorded and compared preoperatively and at 1 week and 1 and 3 months postoperatively.
RESULTS: There was a significant decrease of corneal hysteresis, corneal resistance factor, p1area, and p2area, and an increase of path1 and path2 in both SMILE and LASIK. In myopia -6.00 D or less, the differences between SMILE and LASIK were not significant (P > .05), but in myopia greater than -6.00 D, the corneal hysteresis, corneal resistance factor, p1area, and p2area decreased significantly more in LASIK than in SMILE (P < .05).
CONCLUSIONS: When comparing SMILE with LASIK, myopia was greater than -6.00 D, and the corneal hysteresis, corneal resistance factor, p1area, and p2area decrease was less after SMILE. Copyright 2014, SLACK Incorporated.

Entities:  

Mesh:

Year:  2014        PMID: 25291754     DOI: 10.3928/1081597X-20140903-09

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  30 in total

1.  A microscopic study of the corneal stromal lenticules extracted during femtosecond laser-assisted small incision lenticule extraction.

Authors:  Yewei Yin; Tu Hu; Aiqun Xiang; Yanyan Fu; Yang Zhao; Xiaoying Wu; Xiaoying Wu; Dan Wen
Journal:  Exp Ther Med       Date:  2021-04-25       Impact factor: 2.447

2.  Changes in corneal biomechanics during small-incision lenticule extraction (SMILE) and femtosecond-assisted laser in situ keratomileusis (FS-LASIK).

Authors:  Kaiwei Cao; Lina Liu; Ting Yu; Feng Chen; Ji Bai; Ting Liu
Journal:  Lasers Med Sci       Date:  2019-08-29       Impact factor: 3.161

3.  Contralateral Eye Comparison of SMILE and Flap-Based Corneal Refractive Surgery: Computational Analysis of Biomechanical Impact.

Authors:  Ibrahim Seven; Ali Vahdati; Iben Bach Pedersen; Anders Vestergaard; Jesper Hjortdal; Cynthia J Roberts; William J Dupps
Journal:  J Refract Surg       Date:  2017-07-01       Impact factor: 3.573

4.  Small incision lenticule extraction (SMILE) refractive surgery: Our initial experience.

Authors:  Vijay K Sharma; Alok Sati; Santosh Kumar
Journal:  Med J Armed Forces India       Date:  2021-10-18

5.  Corneal hysteresis in post-radial keratotomy primary open-angle glaucoma.

Authors:  Joshua S Hardin; Christopher I Lee; Lydia F Lane; Christian C Hester; R Grant Morshedi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-07-23       Impact factor: 3.117

6.  Comparison of the Early Clinical Outcomes between Combined Small-Incision Lenticule Extraction and Collagen Cross-Linking versus SMILE for Myopia.

Authors:  Alex L K Ng; Tommy C Y Chan; George P M Cheng; Vishal Jhanji; Cong Ye; Victor C P Woo; Jimmy S M Lai
Journal:  J Ophthalmol       Date:  2016-04-27       Impact factor: 1.909

7.  Quantitative Evaluation of Microdistortions in Bowman's Layer and Corneal Deformation after Small Incision Lenticule Extraction.

Authors:  Rushad Shroff; Mathew Francis; Natasha Pahuja; Leio Veeboy; Rohit Shetty; Abhijit Sinha Roy
Journal:  Transl Vis Sci Technol       Date:  2016-10-17       Impact factor: 3.283

8.  Comparison of Changes in Corneal Biomechanical Properties after Photorefractive Keratectomy and Small Incision Lenticule Extraction.

Authors:  Yusuf Yıldırım; Onur Ölçücü; Abdurrahman Başcı; Alper Ağca; Engin Bilge Özgürhan; Cengiz Alagöz; Ali Demircan; Ahmet Demirok
Journal:  Turk J Ophthalmol       Date:  2016-04-05

9.  Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE).

Authors:  Yang Shen; Xiangjian Su; Xiu Liu; Huamao Miao; Xuejun Fang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2016-11-18       Impact factor: 2.209

10.  Comparison of Two Cap Thickness in Small Incision Lenticule Extraction: 100μm versus 160μm.

Authors:  Miao He; Wei Wang; Hui Ding; Xingwu Zhong
Journal:  PLoS One       Date:  2016-09-21       Impact factor: 3.240