Literature DB >> 24904933

Comparison of corneal deformation parameters after SMILE, LASEK, and femtosecond laser-assisted LASIK.

Yang Shen, Zhi Chen, Michael C Knorz, Meiyan Li, Jing Zhao, Xingtao Zhou.   

Abstract

PURPOSE: To investigate the differences in corneal deformation parameters after femtosecond laser small incision lenticule extraction (SMILE), laser-assisted subepithelial keratomileusis (LASEK), and femtosecond laser-assisted LASIK (FS-LASIK).
METHODS: In this retrospective study, 17 eyes of 17 patients after SMILE, 18 eyes of 18 patients after LASEK, and 17 eyes of 17 patients after FS-LASIK were included. Corneal deformation parameters were measured with the CorVis ST tonometer (Oculus Optikgeräte GmbH, Wetzlar, Germany) 3 months postoperatively.
RESULTS: The mean value of deformation amplitude of the FS-LASIK group was significantly higher than that of the LASEK group (P = .022). The mean value of applanation time (applanation 1) of the LASEK group was significantly higher than that of the FS-LASIK group (P = .038). No significant difference was detected in the mean values of deformation amplitude and applanation time (applanation 1) (P > .05) between the LASEK and SMILE groups or between the SMILE and FS-LASIK groups. Multiple linear regression model analysis revealed that after adjustment for age and preoperative central corneal thickness and manifest refraction spherical equivalent, the significance of the difference in the mean values of applanation time (applanation 1) and deformation amplitude between the LASEK and FS-LASIK groups were P = .084 and .059, respectively. In all three groups, the values of applanation 1 negatively correlated to those of applanation time (applanation 2) (SMILE: r = −0.577, P = .015; LASEK: r = −0.833, P < .001; FS-LASIK: r = −0.516, P = .034) and deformation amplitude (SMILE: r = −0. 556, P = .021; LASEK: r = −0.877, P < .001; FS-LASIK: r = −0.509, P = .037).
CONCLUSIONS: Applanation time (applanation 1) and deformation amplitude (as measured with the CorVis ST tonometer) may be helpful in assessing corneal biomechanical changes after corneal refractive surgery. The relations between these parameters should be discussed in further studies.

Entities:  

Mesh:

Year:  2014        PMID: 24904933     DOI: 10.3928/1081597X-20140422-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  25 in total

1.  Clinical outcomes of small incision lenticule extraction versus femtosecond laser-assisted LASIK for myopia: a Meta-analysis.

Authors:  Huan Yan; Li-Yan Gong; Wei Huang; Yan-Li Peng
Journal:  Int J Ophthalmol       Date:  2017-09-18       Impact factor: 1.779

2.  Influence of LASEK on Schiøtz, Goldmann and dynamic contour Tonometry.

Authors:  Marco Sales-Sanz; Esther Arranz-Marquez; Carolina Arruabarrena; Miguel A Teus
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-10-14       Impact factor: 3.117

3.  Contralateral Eye Comparison of SMILE and Flap-Based Corneal Refractive Surgery: Computational Analysis of Biomechanical Impact.

Authors:  Ibrahim Seven; Ali Vahdati; Iben Bach Pedersen; Anders Vestergaard; Jesper Hjortdal; Cynthia J Roberts; William J Dupps
Journal:  J Refract Surg       Date:  2017-07-01       Impact factor: 3.573

4.  Analysis of corneal biomechanical properties 25 years after myopic photorefractive keratectomy.

Authors:  Sibel Özdoğan; Gökhan Gürelik; Kamil Bilgihan
Journal:  Int Ophthalmol       Date:  2022-08-02       Impact factor: 2.029

5.  Automatic method of analysis and measurement of additional parameters of corneal deformation in the Corvis tonometer.

Authors:  Robert Koprowski
Journal:  Biomed Eng Online       Date:  2014-11-19       Impact factor: 2.819

6.  Changes in corneal deformation parameters after lenticule creation and extraction during small incision lenticule extraction (SMILE) procedure.

Authors:  Yang Shen; Jing Zhao; Peijun Yao; Huamao Miao; Lingling Niu; Xiaoying Wang; Xingtao Zhou
Journal:  PLoS One       Date:  2014-08-14       Impact factor: 3.240

7.  Open source software for the analysis of corneal deformation parameters on the images from the Corvis tonometer.

Authors:  Robert Koprowski
Journal:  Biomed Eng Online       Date:  2015-04-11       Impact factor: 2.819

8.  Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

Authors:  Xiangjun Chen; Aleksandar Stojanovic; Yanjun Hua; Jon Roger Eidet; Di Hu; Jingting Wang; Tor Paaske Utheim
Journal:  PLoS One       Date:  2014-10-10       Impact factor: 3.240

Review 9.  Small Incision Lenticule Extraction (SMILE) versus Femtosecond Laser-Assisted In Situ Keratomileusis (FS-LASIK) for Myopia: A Systematic Review and Meta-Analysis.

Authors:  Zeren Shen; Keda Shi; Yinhui Yu; Xiaoning Yu; Yuchen Lin; Ke Yao
Journal:  PLoS One       Date:  2016-07-01       Impact factor: 3.240

10.  Corneal Biomechanical Properties in Myopic Eyes Measured by a Dynamic Scheimpflug Analyzer.

Authors:  Jingyi Wang; Ying Li; Yumei Jin; Xue Yang; Chan Zhao; Qin Long
Journal:  J Ophthalmol       Date:  2015-10-20       Impact factor: 1.909