Literature DB >> 27712432

A chemical stability study of trimethylsilane plasma nanocoatings for coronary stents.

John Eric Jones1, Qingsong Yu1, Meng Chen2.   

Abstract

Trimethylsilane (TMS) plasma nanocoatings were deposited onto stainless steel coupons in direct current (DC) and radio frequency (RF) glow discharges and additional NH3/O2 plasma treatment to tailor the coating surface properties. The chemical stability of the nanocoatings were evaluated after 12 week storage under dry condition (25 °C) and immersion in simulated body fluid (SBF) at 37 °C. It was found that nanocoatings did not impact surface roughness of underlying stainless steel substrates. X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy were used to characterize surface chemistry and compositions. Both DC and RF nanocoatings had Si- and C-rich composition; and the O- and N-contents on the surfaces were substantially increased after NH3/O2 plasma treatment. Contact angle measurements showed that DC-TMS nanocoating with NH3/O2 treatment generated very hydrophilic surfaces. DC-TMS nanocoatings with NH3/O2 treatment showed minimal surface chemistry change after 12 week immersion in SBF. However, nitrogen functionalities on RF-TMS coating with NH3/O2 post treatment were not as stable as in DC case. Cell culture studies revealed that the surfaces with DC coating and NH3/O2 post treatment demonstrated substantially improved proliferation of endothelial cells over the 12 week storage period at both dry and wet conditions, as compared to other coated surfaces. Therefore, DC nanocoatings with NH3/O2 post treatment may be chemically stable for long-term properties, including shelf-life storage and exposure to the bloodstream for coronary stent applications.

Entities:  

Keywords:  Stents; ageing; nanocoatings; stainless steel; surface modification

Mesh:

Substances:

Year:  2016        PMID: 27712432      PMCID: PMC5117679          DOI: 10.1080/09205063.2016.1239947

Source DB:  PubMed          Journal:  J Biomater Sci Polym Ed        ISSN: 0920-5063            Impact factor:   3.517


  37 in total

Review 1.  Stent-based antirestenotic coatings (sirolimus/paclitaxel).

Authors:  Martin Oberhoff; Christian Herdeg; Andreas Baumbach; Karl R Karsch
Journal:  Catheter Cardiovasc Interv       Date:  2002-03       Impact factor: 2.692

2.  Evaluation of plasma polymer-coated contact lenses by electrochemical impedance spectroscopy.

Authors:  C M Weikart; Y Matsuzawa; L Winterton; H K Yasuda
Journal:  J Biomed Mater Res       Date:  2001-03-15

Review 3.  Stent coating: a new approach in interventional cardiology.

Authors:  Heinrich Wieneke; Thomas Sawitowski; Stephan Wnendt; Alfons Fischer; Olaf Dirsch; Ira Ariadne Karoussos; Raimund Erbel
Journal:  Herz       Date:  2002-09       Impact factor: 1.443

Review 4.  Coronary stents: current status.

Authors:  Scot Garg; Patrick W Serruys
Journal:  J Am Coll Cardiol       Date:  2010-08-31       Impact factor: 24.094

5.  Corrosion resistance improvement for 316L stainless steel coronary artery stents by trimethylsilane plasma nanocoatings.

Authors:  John Eric Jones; Meng Chen; Qingsong Yu
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-02-06       Impact factor: 3.368

6.  Xanthine oxidoreductase catalyses the reduction of nitrates and nitrite to nitric oxide under hypoxic conditions.

Authors:  T M Millar; C R Stevens; N Benjamin; R Eisenthal; R Harrison; D R Blake
Journal:  FEBS Lett       Date:  1998-05-08       Impact factor: 4.124

7.  Coronary artery vasoconstriction routinely occurs after percutaneous transluminal coronary angioplasty. A quantitative arteriographic analysis.

Authors:  T A Fischell; G Derby; T M Tse; M L Stadius
Journal:  Circulation       Date:  1988-12       Impact factor: 29.690

Review 8.  Sirolimus and Paclitaxel on polymer-based drug-eluting stents: similar but different.

Authors:  Rainer Wessely; Albert Schömig; Adnan Kastrati
Journal:  J Am Coll Cardiol       Date:  2006-01-26       Impact factor: 24.094

9.  Platelet-derived growth factor promotes smooth muscle migration and intimal thickening in a rat model of balloon angioplasty.

Authors:  A Jawien; D F Bowen-Pope; V Lindner; S M Schwartz; A W Clowes
Journal:  J Clin Invest       Date:  1992-02       Impact factor: 14.808

10.  Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial.

Authors:  Juan Luis Gutiérrez-Chico; Robert Jan van Geuns; Evelyn Regar; Willem J van der Giessen; Henning Kelbæk; Kari Saunamäki; Javier Escaned; Nieves Gonzalo; Carlo di Mario; Francesco Borgia; Eveline Nüesch; Héctor M García-García; Sigmund Silber; Stephan Windecker; Patrick W Serruys
Journal:  Eur Heart J       Date:  2011-06-09       Impact factor: 29.983

View more
  2 in total

Review 1.  Surface engineering at the nanoscale: A way forward to improve coronary stent efficacy.

Authors:  Aleena Mary Cherian; Shantikumar V Nair; Vijayakumar Maniyal; Deepthy Menon
Journal:  APL Bioeng       Date:  2021-06-01

2.  A Biocompatibility Study of Plasma Nanocoatings onto Cobalt Chromium L605 Alloy for Cardiovascular Stent Applications.

Authors:  Thithuha Phan; John E Jones; Meng Chen; Doug K Bowles; William P Fay; Qingsong Yu
Journal:  Materials (Basel)       Date:  2022-08-29       Impact factor: 3.748

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.