Literature DB >> 16487832

Sirolimus and Paclitaxel on polymer-based drug-eluting stents: similar but different.

Rainer Wessely1, Albert Schömig, Adnan Kastrati.   

Abstract

Recent clinical studies that investigated the efficacy of the two U.S. Food and Drug Administration-approved drug-eluting stent (DES) platforms Cypher (Cordis, Johnson and Johnson, Miami Lakes, Florida) and Taxus (Boston Scientific, Boston, Massachusetts) suggest that there are differences between both DES concerning neointimal growth. Both DES elute compounds that inhibit the cell cycle, but at different stages: Cypher stents elute sirolimus, which induces G1 cell cycle inhibition, and Taxus stents release paclitaxel, which predominantly leads to M-phase arrest. In an attempt to explain the differences observed in human studies, the properties of these stent-based compounds on critical molecular and cellular events associated with the pathophysiology of in-stent restenosis are discussed in detail with the conclusion that both sirolimus and paclitaxel are different in their pleiotropic anti-restenotic effects. This may be in part responsible for the differences observed in recent clinical studies.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16487832     DOI: 10.1016/j.jacc.2005.09.047

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  32 in total

Review 1.  The Pathogenesis and treatment of the valvulopathy of aortic stenosis: Beyond the SEAS.

Authors:  Sammy Elmariah; Emile R Mohler
Journal:  Curr Cardiol Rep       Date:  2010-03       Impact factor: 2.931

2.  Difference in neointimal coverage at chronic stage between bare metal stent and sirolimus-eluting stent evaluated at stent-strut level by optical coherence tomography.

Authors:  Shinichiro Ikuta; Kazuhiro Kobuke; Yoshitaka Iwanaga; Yoshifumi Nakauchi; Kenji Yamaji; Shunichi Miyazaki
Journal:  Heart Vessels       Date:  2013-06-21       Impact factor: 2.037

Review 3.  Paclitaxel-eluting stents versus sirolimus-eluting stents in patients with diabetes mellitus undergoing percutaneous coronary intervention: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Hui-Bo Wang; Ping Zeng; Jun Yang; Jian Yang; Xiao-Wen Liu
Journal:  Intern Emerg Med       Date:  2016-09-08       Impact factor: 3.397

4.  The stent-eluting drugs sirolimus and paclitaxel suppress healing of the endothelium by induction of autophagy.

Authors:  Shin-ichiro Hayashi; Akitsugu Yamamoto; Fukka You; Kentaro Yamashita; Yuka Ikegame; Masahiro Tawada; Tamotsu Yoshimori; Shigeomi Shimizu; Shigeru Nakashima
Journal:  Am J Pathol       Date:  2009-10-08       Impact factor: 4.307

Review 5.  Delivery of large biopharmaceuticals from cardiovascular stents: a review.

Authors:  Hironobu Takahashi; Didier Letourneur; David W Grainger
Journal:  Biomacromolecules       Date:  2007-10-12       Impact factor: 6.988

Review 6.  New drug-eluting stent concepts.

Authors:  Rainer Wessely
Journal:  Nat Rev Cardiol       Date:  2010-03-02       Impact factor: 32.419

7.  Modeling and analysis of drug-eluting stents with biodegradable PLGA coating: consequences on intravascular drug delivery.

Authors:  Xiaoxiang Zhu; Richard D Braatz
Journal:  J Biomech Eng       Date:  2014-11       Impact factor: 2.097

8.  Metformin impairs endothelialization after placement of newer generation drug eluting stents.

Authors:  Anwer Habib; Vinit Karmali; Rohini Polavarapu; Hirokuni Akahori; Kim Pachura; Aloke V Finn
Journal:  Atherosclerosis       Date:  2013-06-14       Impact factor: 5.162

9.  Paclitaxel distribution in poly(ethylene glycol)/poly(lactide-co-glycolic acid) blends and its release visualized by coherent anti-Stokes Raman scattering microscopy.

Authors:  Eunah Kang; Joshua Robinson; Kinam Park; Ji-Xin Cheng
Journal:  J Control Release       Date:  2007-05-17       Impact factor: 9.776

Review 10.  Factors that affect mass transport from drug eluting stents into the artery wall.

Authors:  Barry M O'Connell; Tim M McGloughlin; Michael T Walsh
Journal:  Biomed Eng Online       Date:  2010-03-09       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.