Literature DB >> 27698590

Dosimetric feasibility of an "off-breast isocenter" technique for whole-breast cancer radiotherapy.

Juan-Francisco Calvo-Ortega1, Sandra Moragues1, Miquel Pozo1, Joan Casals1.   

Abstract

AIM: To investigate the viability of placing the treatment isocenter at the patient midline for breast cancer radiotherapy in order to avoid the risk of collisions during image-guided setup and treatment delivery.
BACKGROUND: The use of kilovoltage orthogonal setup images has spread in last years in breast radiotherapy. There is a potential risk of an imaging system-patient collision when the isocenter is laterally placed.
MATERIALS AND METHODS: Twenty IMRT plans designed by placing the isocenter within the breast volume ("plan_ref"), were retrospectively replanned by shifting the isocenter at the patient's midline ("plan_off-breast"). An integrated simultaneous boost (SIB) technique was used. Multiple metrics for the planning target volumes (PTVs) and organs at risk (OARs) were compared for both approaches using a paired t test.
RESULTS: Comparing plan_ref vs. plan_off-breast, no significant differences in PTV coverage (V95%) were found (96.5% vs. 96.2%; p = 0.361 to PTVbreast; 97.0% vs. 97.0%; p = 0.977 to PTVtumor_bed). With regard to OARs, no substantial differences were observed in any analyzed metric: V5Gy (30.3% vs. 31.4%; p = 0.486), V20Gy (10.3% vs. 10.3%; p = 0.903) and mean dose (7.1 Gy vs. 7.1 Gy; p = 0.924) to the ipsilateral lung; V5Gy (11.2% vs. 10.0%; p = 0.459), V30Gy (0.7% vs. 0.6%; p = 0.251) and mean dose (2.3 Gy vs. 2.2 Gy; p = 0.400) to the heart; and average dose to the contralateral breast (0.4 Gy vs. 0.5 Gy; p = 0.107).
CONCLUSIONS: The off-breast isocenter solution resulted in dosimetrically comparable plans as the reference technique, avoiding the collision risk during the treatment session.

Entities:  

Keywords:  Collision; IMRT; Isocenter; Off-breast; SIB

Year:  2016        PMID: 27698590      PMCID: PMC5036509          DOI: 10.1016/j.rpor.2016.06.001

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  17 in total

1.  A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations.

Authors:  W Ulmer; J Pyyry; W Kaissl
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

2.  On-line localization of the lumpectomy cavity using surgical clips.

Authors:  Leonard H Kim; John Wong; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-15       Impact factor: 7.038

3.  A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate.

Authors:  A van't Riet; A C Mak; M A Moerland; L H Elders; W van der Zee
Journal:  Int J Radiat Oncol Biol Phys       Date:  1997-02-01       Impact factor: 7.038

4.  Estimation of optimal matching position for orthogonal kV setup images and minimal setup margins in radiotherapy of whole breast and lymph node areas.

Authors:  Marko Laaksomaa; Mika Kapanen; Tanja Skyttä; Seppo Peltola; Simo Hyödynmaa; Pirkko-Liisa Kellokumpu-Lehtinen
Journal:  Rep Pract Oncol Radiother       Date:  2014-07-15

5.  Three-year outcomes of breast intensity-modulated radiation therapy with simultaneous integrated boost.

Authors:  Mark W McDonald; Karen D Godette; Daisy J Whitaker; Lawrence W Davis; Peter A S Johnstone
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-09-21       Impact factor: 7.038

6.  Assessment of the residual error in soft tissue setup in patients undergoing partial breast irradiation: results of a prospective study using cone-beam computed tomography.

Authors:  Toyosi Fatunase; Zhiheng Wang; Sua Yoo; Jessica L Hubbs; Robert G Prosnitz; Fang-Fang Yin; Lawrence B Marks
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-09-24       Impact factor: 7.038

7.  Early clinical experience with kilovoltage image-guided radiation therapy for interfraction motion management.

Authors:  Joshua D Lawson; Tim Fox; Eric Elder; Adam Nowlan; Lawrence Davis; James Keller; Ian Crocker
Journal:  Med Dosim       Date:  2008       Impact factor: 1.482

8.  Clinical implementation of kilovoltage cone beam CT for the verification of sequential and integrated photon boost treatments for breast cancer patients.

Authors:  E M Donovan; I Castellano; S Eagle; E Harris
Journal:  Br J Radiol       Date:  2012-05-02       Impact factor: 3.039

9.  Simultaneous integrated boost for adjuvant treatment of breast cancer--intensity modulated vs. conventional radiotherapy: the IMRT-MC2 trial.

Authors:  Vasileios Askoxylakis; Alexandra D Jensen; Matthias F Häfner; Leonie Fetzner; Florian Sterzing; Joerg Heil; Christof Sohn; Johannes Hüsing; Uta Tiefenbacher; Frederik Wenz; Jürgen Debus; Holger Hof
Journal:  BMC Cancer       Date:  2011-06-15       Impact factor: 4.430

10.  Phase I-II study of hypofractionated simultaneous integrated boost using volumetric modulated arc therapy for adjuvant radiation therapy in breast cancer patients: a report of feasibility and early toxicity results in the first 50 treatments.

Authors:  Marta Scorsetti; Filippo Alongi; Antonella Fogliata; Sara Pentimalli; Pierina Navarria; Francesca Lobefalo; Carlos Garcia-Etienne; Alessandro Clivio; Luca Cozzi; Pietro Mancosu; Giorgia Nicolini; Eugenio Vanetti; Marco Eboli; Carlo Rossetti; Arianna Rubino; Andrea Sagona; Stefano Arcangeli; Wolfgang Gatzemeier; Giovanna Masci; Rosalba Torrisi; Alberto Testori; Marco Alloisio; Armando Santoro; Corrado Tinterri
Journal:  Radiat Oncol       Date:  2012-08-28       Impact factor: 3.481

View more
  1 in total

1.  Multi-institutional evaluation using the end-to-end test for implementation of dynamic techniques of radiation therapy in Thailand.

Authors:  Lalida Tuntipumiamorn; Puangpen Tangboonduangjit; Taweap Sanghangthum; Rattapol Rangseevijitprapa; Chirasak Khamfongkhruea; Thida Niyomthai; Boonrut Vuttiprasertpong; Supranee Supanant; Nongnuch Chatchaipaiboon; Porntip Iampongpaiboon; Pitchayut Nakkrasae; Tanwiwat Jaikuna
Journal:  Rep Pract Oncol Radiother       Date:  2018-11-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.